1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here

Series-1251-1253-1254
Heavy-Duty Carbon Steel Switch Assemblies with External Magnet – NEMA Rated
Series-1251-1253-1254
From
$
0.00

Can't find the right model?
Use our custom configurator to fine tune your product
Product Overview
PDFs & Manuals
Show Ratings & Reviews
EXAMPLE | 1251 | WT | 7810 | C1 | 40 | 1251-WT-7810-C1-40 Liquid Level Control, weatherproof enclosure, SPDT snap switch, fixed deadband, automatic reset, operating pressure 1250 psig (86 bar) at 100°F (38°C), 1250 psig (86 bar) at 500°F (260°C), side/bottom process connections, 1" NPT/socket weld hubs, minimum specific gravity 0.40. | |
CONNECTION | 1251 | One Horizontal and One Vertical 1" Socket Weld or 1" NPT Combination Hub | |||||
1253 | One Vertical and One Horizontal Flanged Connection | ||||||
1254 | Two Vertical Flanged Connections | ||||||
1254T | |||||||
ENCLOSURE | G | General Purpose, NEMA 1 | |||||
WT | Weatherproof, NEMA 3R, 4, 4X | ||||||
E | Explosion-proof, NEMA 7, 9, Class I Groups B, C, D, Class II Groups E, F, G | ||||||
EV | Explosion-proof/Vapor-proof, NEMA 7, 9, Class I Groups B, C, D, Class II Groups E, F, G | ||||||
CIRCUITS (for electrical circuits see charts A & B below) |
48XX | Single Stage Mercury Switch, see chart A | |||||
48XX-XX | Two Stage, Mercury Switch, see chart A | ||||||
78XX | Single Stage, Snap Switch, see chart B | ||||||
78XX-XX | Two Stage, Snap Switch, see chart B | ||||||
78XXHM | Hermetically Sealed Snap Switch, see chart B | ||||||
98XX | Single Stage, High Capacity DC Snap Switch, use heat fins (HF) if process temperature exceeds 350°F (177°C), do not exceed 450°F (232°C), see chart B | ||||||
98XX-XX | Two Stage, High Capacity DC Snap Switch, use heat fins (HF) if process temperature exceeds 350°F (177°C), do not exceed 450°F (232°C), see chart B | ||||||
CHAMBER MATERIAL | C1 | Carbon Steel Body | |||||
C216 | 316SS Body | ||||||
HFC1 | Heat Fins & Carbon Steel Body | ||||||
HFC216 | Heat Fins & 316SS Body (1251, 1253 only) | ||||||
MINIMUM SPECIFIC GRAVITY |
40 | 0.40 Specific Gravity (1251 only) | |||||
140 | 0.40 Specific Gravity & 150# Flange (1253, 1254 only) | ||||||
340 | 0.40 Specific Gravity & 300# Flange (1253, 1254 only) | ||||||
640 | 0.40 Specific Gravity & 600# Flange (1253, 1254 only) | ||||||
OPTIONS | STW | SS Tag Wired | |||||
01 | Breather Only (E-Housing only) | ||||||
02 | Drain Only (E-Housing only) | ||||||
12 | Breather & Drain (E-Housing only) | ||||||
23720 | Fungus Proofing |
CHARTS A & B - ELECTRICAL CIRCUITS AND RATINGS
SWITCH TYPE | SWITCH ACTION | ELECTRICAL RATINGS IN AMPS | ORDERING CODE | |||||||
AC | DC | SINGLE STAGE | TWO STAGE | |||||||
120V | 240V | 440V | 30V | 125V | 250V | LOWER | UPPER | |||
CHART A Mercury Contacts |
SP-ST open on level FALL | 10 | 5 | 3† | 10 | 5 | -4820 | -4820 | -21 | |
SP-ST open on level RISE | 10 | 5 | 3† | 10 | 5 | -4821 | -4821 | -20 | ||
SP-DT one switch | 4 | 2 | 1† | 4 | 2 | -4810 | -4810 | -10 | ||
SP-DT two switches E.I.* | 10 | 5 | 3† | 10 | 5 | -4815 | -4815 | -15 | ||
DP-ST two switches E.I.* open on level FALL | 10 | 5 | 3† | 10 | 5 | -4814 | -4814 | -13 | ||
DP-ST two switches E.I.* open on level RISE | 10 | 5 | 3† | 10 | 5 | -4813 | -4813 | -14 | ||
DP-DT two SP-DT switches | 4 | 2 | 1† | 4 | 2 | -4806 | -4806 | -06 | ||
CHART B snap action contacts |
SP-DT one switch | 12 | 5 | 3† | 0.5** | 0.25** | -7810 | -7810 | -10 | |
DP-DT two SP-DT switches | 12 | 5 | 3† | 0.5** | 0.25** | -7806 | -7806 | -06 | ||
SP-DT one hermetically sealed switch | 5 | 5 | 5** | -7810HM | -7810HM | -10HM | ||||
DP-DT two hermetically sealed SP-DT switches | 5 | 5 | 5** | -7806HM | -7806HM | -06HM | ||||
DP-DT two SP-DT switches | 10 | 3 | 10‡ | 3‡ | -9806 | -9806 | -06 | |||
SP-DT one switch | 10 | 3 | 10‡ | 3‡ | -9810 | -9810 | -10 |
‡10 amp inductive (polarized) at 125 VDC.
*Electrically Independent.
**Resistive.