Need assistance? Call us: 1-800-663-4209
RD9900-Series
Paperless Recorder Data Acquisition System w/ 6 or 12 Inputs
Models In Stock
- 6 or 12 Point Models Available (12 Point Shown)
- Clear 5.6' TFT Color LCD Display
- Large Capacity of Data Memory and Various Recording Method
- Multi-Points Recording with High-Speed/ Accuracy
RD9900-Series
From
$
4,338.52
Models In Stock
Product Overview
- Accuracy Detail Reference Junction Compensation Accuracy: Type K, E, J, T, N, Platinel II; ±0.5°C or less; R, S, NiMo-Ni, CR-AuFe, WRe5-WRe26, W-Wre, U, L; ±1.0°C or less
- Case Material Steel
- Data Interface Ethernet, USB
- Data Interface Note Communication interface for high-order instruments RS232C/RS485 switchable , Ethernet and USB equipped as standard; Transfer Systems: Bulk transfer, control transfer; Communication Contents: File transfer by virtual drive connections; Number of Logging Files: 250/numbers of used groups; Logging Data: Measured data; file name (group name), time of day, month and year of recording start, tag, measured data, alarm status/types; Recording Cycle: Up to 3 groups of 12 points/group can be programmed for 100, 200 and 500 ms recording; 5 groups of 44 points/group for recording with 1s or more (total of 100 points programming possible)
- Dielectric Strength Dielectric Strength Between Channels: 1000 Vac or more between each channel (high strength semiconductor relay used)
- Display Note TFT color LCD, LCD Back Light: Auto/manual OFF function LCD Brightness: 4 levels adjustment Display Types: Measured Data Display: Trend screen, data screen, bar-graph screen Historical Trend Display: Simultaneous display with real-time trend is available Information Display: Alarm display, marker list, file list Setting Screen: Alarm, computation, memory, system, maintenance, communication, etc. Trend Screen: 12 colors selectable Display Screen: 5 screens (5 groups) Display Points: Maximum 44 points/screen/ Time Axis Direction: Vertical or horizontal Line Width: 1/3/5 dot selectable Scale Display: 4 scales Tag/Data Display (Show/hide selectable) Data Screen: Display screen, 5 screens (5 groups) Display Points: Maximum 44 points/screen Display Contents: Measured value, channel/tag, unit, alarm status Bargraph Screen: 12 colors selectable Display Screen: 5 screens (5 groups) Display Points: Maximum 44 points/screen Display Direction: Vertical or horizontal Scale Display: 1 scale Information Display: Alarm Display (Alarm activation/released history display) Marker List File List (Group data file list display)
- Display Size 142 mm (5.6 in)
- Display Type LCD
- Electrical Connection Note Power Terminals/Protective Conductor Terminals/Communications Terminals: M4.0 Measuring Input Terminals/Alarm Output Terminals/Remote Contact Terminals: M3.5
- Enclosure Color Gray
- Features Computation Points: 44
- Height 144 mm
- Impedance Input 1 MΩ
- Input Note DC Voltage, Thermocouple Input; Approximately 1 MΩ; Signal Source Resistance: Thermocouple Input (Burnout Disable)/DC Voltage Input (±2V or less): 1 kΩ or less, DC Voltage Input (±5 to ±50V): 100 Ω or less, Resistance Thermometer: Per wire 10 Ω or less (same resistance for 3 wires);Max Rating: DC voltage input (±2V or less)/thermocouple input (burnout disable), ±10 Vdc
- Input Voltage ± 60 Vdc
- Insulation Resistance 20 MΩ @ 500 Vdc
- Length 204 mm
- Measurement Type Universal
- Memory 32 MB to 2 GB Capacity: Compact Flash; 128 MB Compact Flash Card is included as Standard
- Memory Note Compact Flash card, 32 MB to 2 GB Capacity; 128 MB Compact Flash Card is included as Standard
- Mounting 1/2 DIN Panel Mount
- Operating Temperature, Max 60 °C
- Operating Temperature, Min -20 °C
- Relative Humidity 5 to 90% RH
- Relative Humidity Note Reference Operating Condition: 45 to 65% RH Normal Operating Condition: 20 to 80% RH Transportation Condition: 5 to 90% RH (note: no dew condensation)
- Sampling Rate 10 Hz (10 updates/second)
- Series ID RD9900-Series
- Storage Temperature, Max 60 °C
- Storage Temperature, Min -20 °C
- Supply Power Note 100 to 240 Vac (universal power supply); 50/60 Hz,Maximum Power Consumption: 50 VA (DO: all points ON, 240 Vac),Reference Operating Condition:,Power Voltage: 100 Vac, ±1.0%,Power Frequency: 50/60 Hz ±0.5%,Normal Operating Condition:,Power Voltage: 90 to 264 Vac,Power Frequency: 50/60 Hz ±2%;Power Failure Protection: Setups and data are backed up by flash memory Clock: Lithium battery backs up RAM (minimum 5 years)
- Supply Power Type AC
- Supply Voltage 100 to 240 Vac
- Vibration Resistance 10 to 60 Hz, 0.5 G (4.9 m/s²) or less ; Impact: 40 G (392 m/s²) or less
- Warm Up Time Longer than 30 minutes
- Weight 2.2 kg
- Width 144 mm
Supported Applications
The Omega RD9900 Series is a network-compatible paperless recorder designed for data management, research and development, and remote or wide-range monitoring. The system supports intranet and internet environments to enable web browser-based display on multiple computers, FTP transfer of data files, and e-mail notifications.
Operating Conditions & Performance
The RD9900 Series features a 144 mm (5.67") TFT color LCD with high-speed sampling at approximately 100 ms for all points. Measurement inputs include thermocouples, DC voltage, and resistance thermometers. Accuracy specifications are defined by input type: Type K, E, J, T, N, Platinel II offer ±0.5°C or less; R, S, NiMo-Ni, CR-AuFe, WRe5-WRe26, W-Wre, U, L offer ±1.0°C or less.
Operating conditions are rated for an ambient temperature of 0 to 50°C and humidity of 20 to 80% RH (normal operating). Storage and transportation ranges extend from -20 to 60°C with a maximum vibration rating of 10 to 60 Hz, 0.5 G (4.9 m/S²) or less.
Recording Capacity
Data is stored in internal flash memory (4 MB capacity) and external CompactFlash cards ranging from 32 MB to 2 GB. Recording duration varies by channel count, sampling cycle, and card size:
- 6 Channels: At a 0.1 sec recording cycle with a 2 GB CF card, the recorder supports up to 101 days of storage.
- 12 Channels: At a 0.1 sec recording cycle with a 2 GB CF card, the recorder supports up to 50.6 days of storage.
Electrical Isolation & Safety
The unit provides dielectric strength between channels of 1000 Vac or more using high-strength semiconductor relays. Insulation resistance is rated at 20 MΩ or more at 500 Vdc for primary/secondary terminals and protective conductor terminals.
Configuration Options
The series offers configurable measurement points, communication interfaces, alarm outputs, and power options to meet specific installation needs.Measurement Points & Sampling Rate
- RD9906: 6-point input / 100 ms sampling rate.
- RD9912: 12 point input / 100 ms sampling rate.
Communication Interfaces
Ethernet and USB are equipped as standard. Optional communication interfaces include the RD9900-C24, which provides a switchable High order RS-232C/RS-485 interface with Low order RS-485.
Alarm & Output Options
- RD9900-AL12: 12-point mechanical relay alarm output (contact capacity: 100 Vac 0.5 A, 240 Vac 0.2 A).
- ZAILA Software: RD9900-ZAILA data analysis software is available as an option.
Housing & Mounting
The recorder features a steel case with ABS resin door frame, designed for panel mounting. Dimensions are 203.6 mm (8.02 in) width x 161 mm (6.34 in) height x 137 mm (5.39 in) depth.Key Product Differences
The primary distinction between models is the number of measuring points: RD9906 supports 6 channels, while RD9912 supports 12 channels. Both variants share identical display specifications, including a maximum of 44 points per screen across 5 groups (screens), and support for trend, data, bar-graph, alarm, marker list, file list, and setting screens.Input configurations allow burnout detection with selectable UP/DOWN disable for thermocouple and resistance thermometer inputs. Scaling is programmable for DC voltage/current ranges. Digital filtering utilizes a programming FIR filter common to all points.
PDFs & Manuals
Accessories
accessories
Show Ratings & Reviews
Can this recorder be outfitted to measure humidity in addition to temperature? If yes, what probe is recommended and how do you program the device?
Hi Yonas,
The RD9906 accepts TC, RTD, and voltage signals. Please forward request to TEMP@OMEGA.COM for assistance selecting humidity sensor for your application.
Best regards
OMEGA
Date published: 2023-06-18
Can temp resolution be set to 0.01C? Our current system from Yokogawa has minimum resolution of 0.1C which is not fine enough.
Thank you for the inquiry. Resolution is limited to 0.1 for temperature inputs. Exception is 1 degree for platinum and tungsten TC's.
Best regards
OMEGA
Date published: 2022-12-05
what are the temperature ranges it reads?
Thank you for the inquiry. Manual page 96 of the manual provides the available sensor types and ranges.
https://assets.omega.com/manuals/M4450.pdf
Best regards
OMEGA
Date published: 2024-05-06
Is there a procedure for field calibration you can provide? Thanks Bruce
Hi Bruce18,
Thank you for the inquiry. Please refer to chapter 16 of the operation manual.
Best regards
OMEGA
Date published: 2022-03-03
Does Omega buy back these machines? Thanks
Thank you for your question. Omega does not buy back any products.
Date published: 2022-07-05