Product Overview
  • Accuracy ± 0.25 %
  • Accuracy Class 0.1% to 0.25%
  • Accuracy Detail ± 0.25% RSS FS at constant temperature (includes linearity, repeatability and hysteresis)
  • Additional Features 1 None
  • Cavity Volume 4.4 CC positive port, 1.3 cc negative port
  • Compatible Meters DP41-E, DP25B-E, DP-7700
  • Compensated Temperature, Max 65 °C
  • Compensated Temperature, Min -1 °C
  • Electrical Connection Screw Terminal w/ 22.2 mm (0.875") conduit opening
  • Electrical Output 4 to 20 mA
  • Enclosure Ratings IP65, NEMA Type 4
  • Hysteresis 0.10% FS
  • Line/Static Pressure 250 psig
  • Linearity Error ± 0.20%
  • Loop Resistance, Max 1000 Ω
  • Operating Temperature, Max 80 °C
  • Operating Temperature, Min -18 °C
  • Output Signal Current
  • Measurement Pressure Type Differential
  • Process Connection Size 1/4 in
  • Process Connection Type NPT Female
  • Repeatability Error ± 0.05% FSO
  • Response Time 50 ms
  • Response Time Note 50 ms (water)
  • Sensing Element Capacitive
  • Series ID PX2300
  • Supply Power Note 24 Vdc nominal Max: 30 + 0.004 x (loop resistance Ω) Vdc Min: 11 + 0.02 x (loop resistance Ω) Vdc
  • Supply Voltage 24 Vdc
  • Thermal Effect on Zero error, Max <± 0.02% FS/°F , <± 0.02% FS/°F
  • Weight 410 g

Supported Applications

The Omega PX2300 Series consists of high-output, low differential pressure transducers designed for wet-to-wet measurement. These units are compatible with most media ranging from dry air to corrosive liquids and are intended for industrial applications where dependability in harsh environments is required. The series is specifically noted for measuring pressure drop across filters and other process devices.

Important usage constraints include:

  • Patient-connected prohibition: These products are not designed for use in, and should not be used for, patient-connected applications.
  • High line pressure configuration: For differential pressure measurements at high line pressures (250 psig max.), it is recommended to install the sensor with a valve in each line plus a shunt valve across the high and low pressure ports.

Operating Conditions & Performance

The PX2300 Series delivers 4 to 20 mA output signals with an accuracy of ±0.25% RSS FS at constant temperature (includes linearity, repeatability, and hysteresis). The series supports a maximum line pressure rating of 250 psig.

Performance is influenced by environmental conditions:

  • Ambient Temperature: -1 to 65°C (30 to 149°F).
  • Process Temperature: -18 to 86°C (0 to 176°F).
  • Response Time: 50 ms (water).

The unit accuracy is affected during vibration, shock, and acceleration conditions. Specific gravity effects on zero shift are documented in the series data: for ranges ±0.5 psid through 2.0 psig, the effect is -2% FS per g with the high pressure port face up and +2% FS per g face down; for all other ranges, the effect is -1% FS per g (face up) or +1% FS per g (face down).

Zero shift may occur when high differential pressure is applied. The shift can be as much as ±10% FS with overpressure applied to the low port and may be recovered by a positive overpressure.

Configuration Options

The series offers configurable measurement ranges in both uni-directional (DI) and bi-directional (BDI) formats. The available model numbers follow the pattern PX2300--.

  • Uni-directional Ranges: 0 to 1 psid, 0 to 2 psid, 0 to 5 psid, 0 to 10 psid, 0 to 25 psid, 0 to 50 psid, and 0 to 100 psid.
  • Bi-directional Ranges: ±0.5 psid, ±1 psid, ±2.5 psid, ±5 psid, ±10 psid, ±25 psid, and ±50 psid.

The transducers feature 1/4-18 NPT internal fittings for both high and low pressure ports. Wetted materials include 17-4 stainless steel, 300 series stainless steel, FKM (Viton), and silicone O-rings. The electronics are housed in a NEMA 4 (IP65) enclosure with an overall weight of 410 g (14.4 oz).

Electrical specifications include:

  • Power Supply: 24 Vdc nominal; minimum and maximum limits depend on loop resistance.
  • Load Resistance: 0 to 1000 Ω.
  • Electrical Connection: Internal barrier strip with a 22.2 mm (0.875") conduit opening.

The series is calibrated with the diaphragm in the vertical position (pressure ports horizontal). For other orientations, zero adjustment is required. Metric thread adaptors and snubbers are available as options.

Key Product Differences

Variants within the PX2300 Series differ primarily by their measurement range directionality and span:

  • Uni-directional (DI): Models such as PX2300-1DI, PX2300-5DI, etc., measure from 0 to a positive psid value.
  • Bi-directional (BDI): Models such as PX2300-0.5BDI, PX2300-5BDI, etc., measure symmetric ranges around zero (e.g., -5 to 5 psid).

All variants share the same NEMA 4 (IP65) enclosure rating, wetted materials, and electrical output characteristics. The series carries CE approval and a 1 YEAR WARRANTY.

Accessories

Static Pressure Sensors for Manometers & Gages across Air Filters
From $2.55
0 In Stock
Rated 3 out of 5 by from PX2300 This item (PX2300) need to have a calibration certificate so that the user know the accuracy of the instrument.
Date published: 2016-12-19
Rated 5 out of 5 by from Excellent Customer Service Excellent Customer Service Excellent Customer Service
Date published: 2026-02-04
  • y_2026, m_9, d_8, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_US, sid_PX2300-100DI, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 35ms
  • REVIEWS, PRODUCT

Is it possible to order this customized to provide a 0-5VDC electrical output signal?

Asked by: PD Engineer
There is no 0 to 5VDC version of the transmitter available. You can use an external 250 ohm to convert the 4 to 20mA to a 1 to 5VDC
Answered by: Applicatrions Engineer JK
Date published: 2021-09-10

I need details around the mounting bracket for this component (PX2300)

Asked by: jenkiwo
Thank you for your inquiry, The PX2300 Series is supplied with a mounting bracket and two (2) 6-32 x 3/8 hex head screws. First attach bracket to mounting location using holes or band clamp notches available on large section of the bracket. Next, attach the transmitter to bracket by using the two 6-32 x 3/8&rdquo; hex head screws and the two tapped holes located on the underside of the transmitter.
Answered by: rkent
Date published: 2022-08-17

Hello, I just ordered PX2300-1DI and now I want to covert output current into the output pressure. With this regard, could you please share a data sheet/table/ formula for the current to pressure conversion?

Asked by: KM03
Thank you for your inquire. This is a linear output. You would take the output range and divide it by the pressure range to get the output per psi.
Answered by: application engineer je
Date published: 2022-02-04

Hello, I want to use this transducer just as a regular gauge pressure transducer. I.e. I have one inlet for water which gauge pressure I want to measure. I'm going to leave the other inlet open to atmosphere. Will this work?

Asked by: nepomnyi
Yes it will. If you leave the low port open to the atmosphere the unit will act as a 0 to 1 PSIG range sensor
Answered by: Applicatrions Engineer JK
Date published: 2022-08-19

Does the PX2300-2DI come with a calibration certificate?

Asked by: Max1
The PX2300 Series differential sensor do not normally come with any certification. We may be able to offer a NIST certification at an additional charge. You would need to contact our Sales Dept at sales@omega.com
Answered by: Applicatrions Engineer JK
Date published: 2021-04-15
  • y_2026, m_9, d_8, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_5
  • loc_en_US, sid_PX2300-100DI, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 67ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration