1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here
PR-10
RTD Probe with Insulated Wire and Shrink-Tube Support
Models In Stock
- Low temperature range: -50 to 250°C (-58 to 482°F)
- High temperature range: -50 to 450°C (-58 to 842°F)
- Extreme temperature range: -200 to 600°C (-328 to 1112°F)
- 316 SS probe with class A RTD accuracy and configurable options
PR-10
From
$
35.02
Models In Stock
Can't find the right model?
Use our custom configurator to fine tune your product
Product Overview
- Accuracy Class A
- Accuracy Detail Class A from -100 to 450°C (-148 to 842°F); or else Class B
- Cable Material PFA
- Electrical Connection Stripped Leads
- Enclosure Ratings IP67
- Insulation PFA
- Nominal Resistance/Curve Note 100 Ω at 0°C standard; TCR = 0.00385 Ω/Ω/°C standard
- Probe Type RTD Probe with Insulated Wire and Shrink Tube Support
- Sheath Material 316 Stainless Steel
- Shock IEC 60068-2-27; 50g/11ms (15 probes tested together) Duration: 1 day
- Temperature Coefficient 0.00385Ω/Ω/°C
- Temperature Coefficient Note α=0.00385Ω/Ω/°C
- Temperature Probe Style Immersion Probe
- Temperature Sensor Type RTD
- Vibration IEC 60068-2-6; 5 to 2000 Hz sweep rate, one active per minute;10 sweep cycles; acceleration 5g (15 probes tested together) Duration: 1 day
- Wire Gauge 26 AWG
- Wire Termination Temperature, Max 250 °C
The Omega PR-10 Series is a durable RTD probe with insulated wire, designed for reliable and accurate temperature measurement in a wide range of applications. Built with a stainless-steel probe and insulated lead wires, it provides a dependable solution for monitoring temperatures in liquids, solids, and industrial equipment.
Easy to install and resistant to wear, the PR-10 is a versatile choice for engineers, technicians, and OEMs who need consistent performance in demanding environments. Its shrink-tube support helps protect the probe from strain, ensuring long service life and dependable operation.
Backed by the trusted Omega brand, the PR-10 combines quality construction with the accuracy needed for HVAC, process control, laboratory, and industrial monitoring applications.