Skip to search Skip to main content Skip to navigation

1-800-663-4209 | Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

OS550A

Thermomètre infrarouge/émetteur avec affichage, double alarme et sortie analogique

Infrared Thermometer/Transmitter with Display, Dual Alarm and Analog Output
  • Visual and Audible High and Low Alarms with Red LED Indication (OS551A has High Alarm only)
  • Voltage Alarm Outputs to Drive External Relays
  • Fast 100 msec Response Time
  • Two-Way RS232 Communication Available
Infrared Thermometer/Transmitter with Display, Dual Alarm and Analog Output OS550A OS550A
loading all models
L'aperçu du produit
  • Accuracy Detail ± 1% rdg or 1.7°C (3°F),whichever is greater; 25°C ambient, 0.95 emissivity
  • Cable Length 4.5 m
  • Data Interface RS232
  • Display Yes
  • Emissivity, Max 1
  • Emissivity, Min 0.1
  • Emissivity Note 0.10 to 1.00 in 0.01 steps
  • Enclosure Ratings IP65, NEMA Type 4
  • Enclosure Ratings Note NEMA 4 (IP65); sensor head and plastic or aluminum electronics enclosure
  • Intrisically Safe None
  • Laser Beam Diameter 5 mm
  • Laser Classification Class 2
  • Laser Operating Distance 12 m
  • Laser Output false
  • Laser Power <1 mW
  • Laser Wavelength Color 650 nm
  • Operating Temperature, Max 50 °C
  • Operating Temperature, Min 0 °C
  • Output Detail 1 mV/degree, 0 to 5 Vdc or 4 to 20 mA
  • Output Signal Current
  • Sensor Diameter 41 mm
  • Sensor Length 109 mm
  • Spectral Response, Min 8 μm
  • Supply Current 80 mA
  • Supply Voltage 8 to 24 Vdc
  • Weight 0.45 kg
  • Weight Note 0.45 kg (12 oz) sensing head; 1.2 kg (42.3 oz) plastic case

This item has been discontinued

OMEGA's OS550A Series (Upgrade from OS550 Series) industrial, high performance, economical thermometer/transmitter offers a wide choice of temperature ranges, optical fields of view and 3 analog outputs (1 mV/degree, 4 to 20 mA, and 0 to 5 Vdc) to feed directly into panel meters, recorders, temperature/process controllers, data loggers, data acquisition systems, or other process instrumentation. Since the OS550A Series infrared thermometers do not use chopper motors or vibrator mechanisms, they can be mounted in any position and in hostile environments without suffering any loss in performance.

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

OS551A-MA-5....is there an equivalent that can be used instead of this unit...? Pls advise.....also is it still available for ordering...?

Asked by: Bob8900
The OS550A series is no longer sold and the OSAO-Series is a good product to review as an alternative.
Answered by: ApplicationsEngineerANB
Date published: 2021-06-03
  • y_2025, m_10, d_7, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_CA, sid_OS554A-MA-5, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 8ms
  • QUESTIONS, PRODUCT
fr-CA
en
Enregistrer la configuration