Need assistance? Call us: 1-800-663-4209
FP5060-Series
Micro-Flow Polypropylene Sensors For Low Flow Applications
- Measures Flow Rates As Low As 0.03 GPM, 0.11 LPM
- Splash-Proof
- All Plastic Construction for Superior Chemical and Corrosion Resistance
Product Overview
- Longueur du câble 25 m
- Type d'affichage Aucune
- Puissance électrique 10 mA
- Hauteur 1.42 in
- Longueur 3.96 in
- Erreur de Linéarité ±1 %
- Montage Surface horizontale ±30°
- Pression de Fonctionnement, max 80 psi
- Température de fonctionnement, max 80 °C
- Température de fonctionnement, min 0 °C
- Détails de la sortie Transistor NPN à collecteur ouvert, capacité de charge maximale de 10 mA
- Chute de pression maximale 25 psi
- Erreur de Répétabilité 0,005
- ID de série FP5060-Series
- Échelle de viscosité 0 à 20 cPs
- Débit volumétrique, max 2.6 l/min
- Débit volumétrique, min 0.11 l/min
- Poids 9.6 kg
- Width 3.2 in
Supported Applications
The Omega FP-5060 Series Micro-Flow Sensors are designed for measuring low flow rates in clean fluids. These sensors generate pulses proportional to flow volume and are suitable for applications requiring precise flow monitoring of clean process liquids, regardless of fluid color.
Operating Conditions & Performance
The series operates within a process temperature range of 0 to 80 °C (32 to 176 °F) with a maximum pressure rating of 5.5 bar (80 psi). Accuracy is specified as ±1% of full range, and repeatability is 0.5% of full range.
Measurement ranges vary by model:
- FP-5061 and FP-5062: 0.11 to 2.6 lpm (0.03 to 0.7 gpm)
- FP-5063: 1.13 to 12.11 lpm (0.3 to 3.2 gpm)
The sensors are suitable for clean fluids only; suspended solids will cause mechanical failure.
Configuration Options
The FP-5060 Series offers configurable process connections and flow ranges across three primary models:
- Process Connections: ¼ in. NPT (male) or ISO 7/1 - R¼ (male)
- Housing Material: Polyphenylene sulfide
- Wetted Materials:
- Sensor body and cover: 40% glass filled Polyphenylene Sulfide
- Rotor: PEEK, natural, unfilled
- O-rings (Rotor and Cover): Viton® / FKM
- Output Signal: Open-collector NPN transistor, 10 mA max sink
- Power Supply: 5 to 24 VDC, regulated @ 10 mA maximum
- Cable Length: 7.5 m (25')
- Electrical Connection: 2-conductor twisted pair w/shield (Belden 8451)
The series supports horizontal surface mount installation within ±30° for optimum performance; vertical mounting is not recommended. Accessories include the DPF701 rate or total panel meter.
Key Product Differences
Differences between models are defined by port type and flow range:
- FP-5061: ¼ NPT connection; Flow Range: 0.11 to 2.6 LPM (0.03 to 0.7 GPM)
- FP-5062: ISO 7/1-R¼ connection; Flow Range: 0.11 to 2.6 LPM (0.03 to 0.7 GPM)
- FP-5063: ¼ NPT connection; Flow Range: 1.13 to 12.11 LPM (0.3 to 3.2 GPM)
Pulse output rates differ by model, with FP-5061 and FP-5062 generating 9950 pulses per U.S. gallon (2629 pulses per liter), while the higher-flow FP-5063 generates 3160 pulses per U.S. gallon (834.9 pulses per liter).