Good Quality
I'm really happy to have one and I need more... but unfortunately it's very hard to find OMEGA products in IRAN
Date published: 2018-01-23
Rated 4 out of
5
by
Rishabh from
Omega D8400
Reliable DAQ. Just a note that it the software to configure the Channels is not easily or readily available, and there is no manual that goes to explain how to use the software
Date published: 2026-03-12
I have a 4-20mA three-wire Omega LVIT - will this interface work with that? I assume the LVIT (+) would go to a CH (+) but I don't understand what would go in the CH (-) side. Would the LVIT and this share the same power supply or do I need one for each?
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM
Date published: 2022-07-21
Can I use this DAQ with Labview? are there drivers available?
Sorry but the device cannot be used with Labview.
Date published: 2022-07-15
Can DS8400 be interfaced to a linux system? i.e will the system detect the device as as virtual COM port? any specific USB serial drivers required?
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@dwyeromega.com
Date published: 2023-12-15
What compatible software from Omega can be purchased to fit this product?
Hello, thank you for your question. Complimentary Utility Software is included with each module. The software is compatible with Windows operating systems and distributed on CDROM. The Utility Software simplifies configuration of all user selectable options such as device address, baud rate and filtering constants. The latest version of our software is always available on our web site. Besides the utility software, we don't have any other program design for this unit.
The D8000 series USB interface modules connect to a host computer using a USB interface cable and they communicate using a virtual serial communications port using the Modbus RTU protocol.The Modbus RTU protocol is used to read and write data values to the D8000 series modules. The Modbus RTU protocol is a serial protocol and communicates with external devices through serial ports. The Modbus RTU protocol is widely recognized throughout the data acquisition industry and is supported by almost all commercial process control programs.
Date published: 2021-02-03
I cannot find this utility software anywhere for the D8100 series. I found software for D6000 series but when I try to select the correct module type the D8100 doesn't show up and so I cannot use this software.
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM
Date published: 2023-01-25
Is it possible to connect an S-Beam load cell with 2mv/V output?
Thank you for your question. The correct model for the load cell is D8100. Make sure you power the load cell per specification because D8100 does not provide excitation.
Date published: 2022-11-30
Does the D8400 model support 4-20mA output pressure transducers such as the PX309-500GI?
Thank you for your question. Yes it will.
Date published: 2023-01-12
Do you provide some kind of API for software integration?
We do not provide an API for this device.