Models In Stock
- Panel-mount variable-area flow meter calibrated specifically for oxygen service
- Accuracy ±5% FS, repeatability ±0.25%, with turndown ratio of 10:1
- Rated up to 200 psi process pressure, max temperature ~121 °C for robust application
- Wetted materials include 316 SS or aluminum, back-plate acrylic, panel-mount style for easy integration
FLD-Oxygen-Series
From
$
416.58
Models In Stock
Product Overview
- Accuracy ± 5 %
- Back Plate 1/8" thick white acrylics
- Media Compatibility Inert / non-reactive gases
- Mounting Panel Mount
- Mounting Fittings In Contact With Fluids 316 stainless steel, Aluminum, black anodized
- Number of Tubes 1
- Operating Pressure, Max 200 psi
- Process Connection Size 1/8 in
- Process Connection Type NPT Female
- Process Temperature, Max 121 °C
- Repeatability ± 0.25%
- Scale Direct Read
- Series ID FLD Oxygen-Series
- Turndown Ratio 10:1
Supported Applications
The Omega FLD Series comprises direct read variable area flow meters (rotameters) designed for the measurement of gases and liquids. The series is explicitly documented for metering carrier gases in chromatography, indicating and controlling gases in manufacturing processes, liquid and gas measurement in laboratories and pilot plants, as well as general flow and level indication.
While this specific product listing focuses on Oxygen (O2) calibrated models, the FLD Series architecture supports a broader range of media including Air, Water, Nitrogen (N2), Hydrogen (H2), Carbon dioxide (CO2), Argon (Ar), and Helium (He).
Operating Conditions & Performance
The series delivers standard accuracy of plus/minus 5% of full scale (FS) with a repeatability of plus/minus 0.25%. The useful flow range is specified as a minimum ratio of 10:1, where the minimum flow rate represents 10% of the maximum rate shown for each model.
Performance limits are defined by a maximum operating pressure of 200 psig/13.8 bars and a maximum operating temperature of 121 C (250 F). The meters utilize heavy walled borosilicate glass flow tubes with rib-guided or fluted designs to ensure stable readings.
Oxygen Measurement Ranges
Available Oxygen models are configured for two tube lengths, offering the following maximum flow capabilities:
- 65 mm Tube Length (Models FLDO3301G through FLDO3307ST): Maximum flows range from 1 L/min to 8 L/min and 50 mL/min to 500 mL/min.
- 150 mm Tube Length (Models FLDO3501S through FLDO3507S-HRV): Maximum flows range from 1 L/min to 58 L/min and 250 mL/min to 400 mL/min.
Configuration Options
The FLD Series is configurable across frame materials, float types, valve options, and mounting styles. Models are shipped completely assembled with side plates, a protective magnifying front shield made of polycarbonate resin with a longitudinal lens, a back plate, built-in control valves (unless specified otherwise), and flow tubes.
Construction Materials
- Frames: Aluminum (black anodized) or 316 stainless steel. Note that Oxygen models in this listing are supplied with a 316 SS frame.
- Floats: Options include glass, red sapphire, 316 stainless steel, carboloy, and tantalum. Suffixes denote the float material: G (glass), ST (316SS), C (carboloy), SA (red sapphire).
- O-Rings: Buna O-rings are standard in aluminum/brass models; FKM O-rings are used in stainless steel meters. Perfluoroelastomer and EPR options are available.
Valve & Mounting Options
- Standard Valve: Built-in 6-turn needle valve (inlet mounted standard).
- -HRV Suffix: Adds a 16 turn high resolution non-rising stem metering valve, available for 150 mm meters.
- -NV Suffix: Unit supplied without a valve.
- Mechanical Mounting: Designed for panel mounting with two retaining nuts; requires drilling two 15 mm (0.59 in) holes through panels up to 9.5 mm (0.375 in) thick. Bench mounting is achievable using optional FLTR-1, FLTR-2, or FLTR-3 acrylic tripods.
Special Service Options
- -02CLEAN Suffix: Specifies oxygen cleaning for the unit.
- Fittings: Various materials and styles of fittings are available to suit specific installation needs.
Key Product Differences
The primary distinction within this Oxygen series is tube length, which dictates flow range and physical dimensions. The 65 mm models (FLDO33xx) feature a side view of 47 mm open x 29 mm x 16 mm with an inlet/outlet center distance of 114 mm for the smaller size configuration. The 150 mm models (FLDO35xx) accommodate higher flow rates and have an inlet/outlet center distance of 224 mm.
Model numbers follow a structured guide: FLD[fluid letters][tube/size/range number][float suffix][options]. For example, FLDO3301G indicates an Oxygen meter with a 65 mm tube and glass float, while FLDO3507S-HRV denotes a 150 mm unit with a sapphire float and high-resolution valve.
Valve positioning varies by application: standard inlet mounting is used for gases; liquid applications may utilize valves at inlets or outlets (top); vacuum services require valves mounted at the outlet. If unspecified, meters ship with valves at the inlets.
Show Ratings & Reviews
Rated 5 out of
5
by
FakeSnake from
I got Flow Control...
Omega always has a great selection of products & technical data so you can find what you need...and this was no exception. The right flow range for the job.
Date published: 2018-12-12
Rated 5 out of
5
by
SLaudano from
Quality Product
Meets our needs as expected. Quality product and excellent delivery.
Date published: 2025-02-10
Rated 5 out of
5
by
IA INSTRUMENTS SAC JOSE U from
Rotameter Flow Meter Dwyer Omega FLDN3505C
Is a good product it flow meter Rotameter from Dwyer Omega
Date published: 2025-02-03
Rated 5 out of
5
by
Wm Ed from
Direct Read Flow Meter
Great flow meter and you cant beat the price. I have bought several of these over the years and they always perform well.
Date published: 2024-10-21
Rated 5 out of
5
by
Welders from
Wonderful product
Wonderful product with exact presision, also has an excellent duration
Date published: 2024-05-31
Rated 5 out of
5
by
Kevork from
Hydrogen Flowmeter
Thank you Omega for custom suppling me the Hydrogen Flow meter, which is not available on the market, in a very short time , even beating the estimated time, one again I can't thank you enough. Kevork
Date published: 2024-04-30
Rated 5 out of
5
by
Natalie Fike from
Flow Meter
Great product for measuring liquid or gas. Comes in handy.
Date published: 2024-04-15
For the product FLDN3305G, the readings are in STANDARD LPM?
Thank you for your inquiry. The FLDN3305G has a range of up to 120mL/min. The units on the scale will be in mL/min.
Date published: 2020-04-29
Where do I reed the ball on the FLDA3214G-NV flow meter. The top or the center?
Thank you for your inquiry about the rotameters. The Rule of Thumb is to read the flow rate at the highest and widest part of the float and in this case, a sphere will be the center.
Date published: 2023-08-15
Hi. Can I assume that all FLD series meters are volumetric, or is there an option to order them so that they are standardized?
Thank you for your inquiry. They are calibrated at standard conditions, yet, no options for a calibration certificate.
Date published: 2024-10-07
Ordered an FLDA3420C-NV rotameter. Per spec sheet it has a max flow of 10 L/min. But now see the website says the units are SCFM and the readings on the meter go to 10. Which is the correct measurement unit?
Thanks for your question?
The part number, FLDA3420C-NV, rota-meter with no valve has been confirmed to have a max flow capacity of 10 LPM.
Date published: 2019-07-15
Is the connection 1/8 pipe size? or 1/8'' Outer Diameter?
Thank you for your inquiry. The process connection is 1/8 inch NPT
Date published: 2024-11-20
Is there an option available that can be sanitized in place using peroxyacetic acid?
Thank you for your inquiry. If you would like to use the acid in question to clean, please consult a Chemical compatibility handbook to determine if the wetted materials are chemically compatible.
Date published: 2025-01-23
Certificate Traceable to NIST
Thank you for your inquiry for this rotameter. Unfortunately, there is no option for a NIST certificate for this series, you may consider the FL-3600, 3700, 3800, and 3900 series.
Date published: 2021-01-26
How do I read the flow meter / take the reading of FLDA3212ST model? Do I read the float at the top, middle or bottom? The model we got is FLDA3212ST
Thank you for your inquiry about the rotameters. The Rule of Thumb is the highest and widest part of the float.
Date published: 2023-03-11