FMA6000-Series
Multi Parameter Mass Flow Meter With Flow Totalizer
- Multi-Drop Capability of Up to 256 Units (for RS-485 Option)
- Stores Calibration Data for Up to 10 Different Gases
- Supports 10 Different Engineering Units Including User Defined
- Programmable 12 Digits Totalizer Indicates Total Gas Volume
FMA6000-Series
From
$
2,970.18
Product Overview
- Accuracy ± 1 %
- Accuracy Detail 0°C to 50°C and 5 to 100 psia (34.5 - 689.5 kPa): ± 1% of full scale (F.S.)
- Additional Features 1 2 SPDT 1A Relay, Multi-parameter Display
- Altitude Sensitivity Incremental deviation of up to 1% from stated accuracy, after re-zeroing
- Calibration NIST 10-Point Certificate
- Circuit Protection Reverse polarity, Current Limit, Resettable Fuse
- Data Interface RS485
- Data Interface Note The digital interface operates via RS485 (optional RS232 is available)
- Display Note 128 x 64 graphic LCD with backlight (up to 8 lines of text). User selectable backlight saver.
- Display Type LCD
- Electrical Output 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc
- Enclosure Ratings Inst. Level II/Poll. Degree II (IEC 60664)
- Humidity Range Up to 70%
- Leak Rate Under Vacuum less than 10^⁻9 cc He/s
- Materials, Wetted 316 Stainless Steel, 416 Stainless Steel, FKM
- Media Compatibility Clean dry air / inert gas, HVAC / room air, Inert / non-reactive gases, Oxygen
- Operating Pressure, Max 100 psi
- Operating Pressure, Min 0 psi
- Operating Temperature, Max 50 °C
- Operating Temperature, Min -10 °C
- Output Detail Linear 0-5 Vdc (3000 ohms min load impedance); Linear 0-10Vdc (6000 ohms min impedance); Linear 4-20 mA (500 ohms maximum loop resistance). Maximum noise 20mV peak to peak (for 0-5 Vdc output).
- Output Signal Current, Voltage
- Pressure Accuracy ± 1 %
- Pressure Coefficient 0.01% FS/psi
- Pressure Drop, Max 0.04 psi
- Process Connection Type Compression Fitting
- Process Temperature, Max 50 °C
- Process Temperature, Min 0 °C
- Repeatability ± 0.15%
- Response Time 300 ms
- Response Time Note 300ms time constant; approximately 1 second to within ± 2% of set flow rate for 25% to 100% of full scale flow.
- Series ID FMA6000-Series
- Supply Power Note May be configured for three different options: Bipolar ± 15Vdc (± 200 mA maximum); Unipolar +12Vdc (300 mA maximum); Unipolar +24Vdc (250 mA maximum); Circuit boards have built-in polarity reversal protection. Resettable fuses provide power input protection
- Supply Voltage Bipolar ± 15Vdc, Unipolar 12Vdc to 24Vdc
- Temperature Accuracy ± 1 °C
- Temperature Coefficient 0.15% FS/°C
- Volumetric Flow Rate, Min 0.2 SCCM
- Weight 2.2 lb
Supported Applications
The Omega FMA6000 Series, comprising the FMA6600 and FMA6700 Multi-Parameter Digital Mass Flow Meters, is designed for clean gas applications. These instruments measure flow, pressure, and temperature with digital display capabilities.
- Clean gases only
- Applications requiring simultaneous measurement of flow, pressure, and temperature
The series includes a specific warning regarding oxygen service: FMA6600/6700 transducers should not be used for monitoring OXYGEN gas unless specifically cleaned and prepared for such application.
Operating Conditions & Performance
Performance parameters are defined by the measurement ranges and pressure limits documented in the series manual. The FMA6700 Multi-Parameter versions have a maximum operating pressure of 100 PSIA (6.8 bars); applying pressure above this limit for extended periods will seriously damage the pressure sensor.
- Burst Pressure: 200 PSIA (13.6 bar)
- Measurement Ranges: Includes configurations for 0 to 50 LPM, 15 SLPM to 50 SLPM, and ranges of 60 LPM or greater.
The series is not intended for use with liquids. Media compatibility is restricted to clean gases unless specific preparation steps are followed for oxygen service.
Configuration Options
The FMA6000 Series offers configurable process connections and electrical interfaces tailored to different flow rates and system integration needs.
- Process Connections: 1/4 inch for flows of 50 LPM or less; 3/8 inch for flows of 60 LPM or greater. Optional 1/8 inch inlet and outlet compression fittings are available.
- Electrical Connection: 25 pin 'D' connector
- Output Signals: Available in 0-5 Vdc, 4-20 mA, or RS485/RS232 formats.
- Power Supply: Requires ±15Vdc (bipolar power supply).
The series includes models with flow totalizer functionality and programmable settings. The FMA6700 variants specifically provide multi-parameter measurement capabilities including pressure sensing.
Key Product Differences
The series is divided into two primary model families: the FMA6600 and FMA6700 lines, distinguished by their parameter sets. The 36 enabled SKUs span both families with part numbers ranging from FMA6601 to FMA6618 and FMA6701 to FMA6718.
- FMA6600 Series: Digital mass flow meters focused on flow measurement within the specified ranges.
- FMA6700 Series: Multi-parameter versions that measure flow, pressure, and temperature. These models are subject to the 100 PSIA (6.8 bars) maximum operating pressure limit for the gas line.
All variants in this series carry CE approval certification.