TX93-94-95-Series-Tx
Miniature Head Mount Temperature Transmitters
Models In Stock
TX93-94-95-Series-Tx
From
$
225.68
Models In Stock
Product Overview
- Accuracy ± 0.1 %
- Accuracy Detail ±0.1% FS (includes effects of linearity, hysteresis and repeatability)
- Bandwidth 3 dB @ 3Hz
- Calibration Trimpot
- Electrical Output 4 to 20 mA
- Hysteresis ±0.1%
- Linearity ±0.1%
- Loop Resistance, Max (Vs-8V)/0.02A
- Operating Temperature, Max 85 °C
- Operating Temperature, Min -25 °C
- Repeatability ±0.1%
- Series ID TX93-94-95-Series-Tx
- Setup Controls Trimpot
- Storage Temperature, Max 125 °C
- Storage Temperature, Min -65 °C
- Supply Power Note 8 to 35 Vdc; 24 Vdc recommended
- Supply Power Type DC
- Supply Voltage 8 to 35 Vdc
- Zero Setting Adjustable Range ±25%
Supported Applications
The Omega TX93, TX94, and TX95 series are miniature head mount temperature transmitters designed for thermocouple (J, K, T, or E), RTD (100 Ω Pt, alpha = 0.00385), and voltage input applications. These non-isolated units eliminate long runs of costly field wiring by transmitting a signal that reduces noise pickup, voltage drops, and cold junction errors. The series is intended for use with ungrounded probes.
Operating Conditions & Performance
The transmitters provide an output range of 4 to 20 mA dc with ±0.1% FS accuracy (includes effects of linearity, hysteresis and repeatability). Frequency response is specified at 3 dB @ 3Hz. The ambient temperature operating range is -25 to 85°C (-13 to 185°F), while the storage temperature range extends from -65 to 125°C (-85 to 257°F).
Measurement ranges vary by model and sensor type:
- Thermocouple (J, K, T, E): Ranges include -40 to 49 °C (-40 to 120 °F), -18 to 93 °C (0 to 200 °F), -18 to 149 °C (0 to 300 °F), -18 to 260 °C (0 to 500 °F), -18 to 399 °C (0 to 750 °F), and -18 to 538 °C (0 to 1000 °F).
- RTD: Ranges correspond to the thermocouple codes listed above.
- Voltage Input: Available in 0 to 60 mV dc and 0 to 10 Vdc ranges.
The units require a supply voltage of 8 to 35 Vdc (24 Vdc recommended) with a maximum loop resistance calculated as Vs - 8V / 0.020. Zero and span adjustment range is ±25%.
Configuration Options
The series offers three primary model families based on input type:
- TX93-(*): Thermocouple transmitter (J, K, T, or E).
- TX94-(*): RTD transmitter (100 Ω Pt, alpha = 0.00385) with a 2-lead configuration.
- TX95-(*): Voltage input transmitter.
The series also includes integrated probe options:
- NB1TX93-(*): NB1 thermocouple probe, 305 mm (12") L, 6 mm (¼") OD, ungrounded junction, with a 304 SS sheath and TX93 transmitter.
- PRTX94-(*): PR-12 RTD probe, 305 mm (12") L, 6 mm (¼") OD, with a 304 SS sheath and TX94 transmitter.
The physical dimensions are 1.90 H x 4.45 cm D (0.75 x 1.75"), where height includes the terminal strip electrical connection. The unit weight is 30 g (1 oz). Mounting options include a DIN rail mounting adaptor (TX90-DIN) and various power supplies such as regulated PSR-24S, PSR-24L, PSR-24L-230, or unregulated PSU-93.
Key Product Differences
The TX93 models output a signal proportional to the mV output of the thermocouple and are not linearized to temperature. The series distinguishes between standalone transmitters (TX93/94/95) that mount in a protection head and complete probe assemblies (NB1TX93, PRTX94). Range codes inserted into the model number define the specific measurement span for each sensor type.
PDFs & Manuals
Accessories
accessories
installation hardware
signal conditioners
Show Ratings & Reviews
Does the TX94-1 come pre calibrated or must I calibrate per table 4-1 in manual?
Hi Lucky,
Thank you for the inquiry. These come pre-calibrated. No need for extra adjustments.
Best regards
OMEGA
Date published: 2023-04-26