Models In Stock
  • 130+ Gas Calibrations, Including: He, O2 , Neon, N2O, N2, Air, Argon, CO, CO2, Methane, Ethane, Propane, Butane, Acetylene, Ethylene, H2
  • Pressure, Temperature, Volumetric Mass Flow Simultaneously Displayed
  • Easy Operator Push Button Interface
  • NIST Traceability Standard
FMA2600-FVL2600-Series
From $ 2,564.21
Models In Stock
Mass Flow Controllers with 20+ Gas Select Function FMA2600-FVL2600-Series FMA2600-FVL2600-Series
loading all models
Product Overview
  • Accuracy ± 0.8 %
  • Accuracy Detail ± (0.8% of reading + 0.2%FS)
  • Additional Features 1 Power Supply Included
  • Calibration NIST Certificate
  • Data Interface RS232
  • Display Type LCD
  • Electrical Connection 8-pin mini DIN
  • Excess Flow Rate 2.4% FS
  • Height 3.9 in
  • Humidity Range 0 to 100% RH non-condensing
  • Input Control Signal 0 to 5 Vdc
  • Materials, Wetted Aluminum, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel
  • Media Compatibility Clean dry air / inert gas, HVAC / room air, Inert / non-reactive gases, Oxygen
  • Operating Pressure, Min 0 psi
  • Operating Pressure Note 145 psig To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flow meters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig
  • Operating Temperature, Max 50 °C
  • Operating Temperature, Min 0 °C
  • Measurement Pressure, Min 5 psi
  • Repeatability ± 0.2%
  • Response Time 100 ms
  • Series ID FMA2600-FVL2600-Series
  • Span Shift 0.02% FS/°C/atm
  • Turndown Ratio 200:1
  • Volumetric Flow Rate, Min 0.0025 SCCM
  • Width 1.1 in

Supported Applications

The Omega FMA-2600/FVL-2600 Series comprises mass and volumetric gas flow controllers designed for clean gases. These instruments utilize differential pressure across an internal laminar flow element (LFE) to determine volumetric flow, applying the Poiseuille equation while using separate absolute temperature and pressure sensors to correct rates to standard conditions. The series supports 130+ gas calibrations including pure and mixed gases, with capability for custom live gas blend programming storing up to 20 user-defined blends.

Operating Conditions & Performance

The FMA-2600A Series operates within an ambient temperature range of -10 to 50°C (14 to 122°F) and a humidity rating of 0 to 100% RH, non-condensing. Accuracy is specified as ±(0.8% of reading + 0.2%FS), with repeatability at ±0.2% FS and a turndown ratio of 200:1. Control response time is 100 ms (50 to 100 ms typical). The maximum pressure rating is 145 psig; for volumetric mode operation near atmosphere, the recommended maximum operating pressure is 15 psig.

Minimum differential pressure requirements vary by range: 5 SLM and under requires 5 psid; 10 to 250 SLM requires 15 psid; 500 SLM requires 5 psid; and 1500 SLM requires 10 psid. Zero shift is specified as 0.02%/ATM FS/°C, with span shift at 0.02%/ATM FS/°C.

Measurement Ranges

The series covers full scale ranges from 0.5 SCCM to 3000 SLM. Specific per-model full scales include:

  • SCCM: 0.5, 1, 2, 5, 10, 20, 50, 100, 200, 500
  • SLM: 1, 2, 5, 10, 20, 50, 100, 250, 500, 1000, 2000, 3000

Configuration Options

The series offers configurable output signals and communication protocols. Standard outputs include 0 to 5 Vdc and RS232 communications (RS485 is optional). Optional analog configurations provide 4 to 20 mA, two 4 to 20 mA outputs (-I2), or two 0 to 5 V outputs (-V2). An optional 4 to 20 mA input (-IN) replaces the standard 0 to 5 Vdc control signal.

Process Connections and Wetted Materials

Process connections vary by flow range:

  • 10-32 thread: 0.5 to 50 SCCM models
  • 1/8 FNPT: 100 SCCM to 20 SLM models
  • 1/4 FNPT: 50 to 100 SLM models
  • 1/2 FNPT: 250 SLM model
  • 3/4 FNPT: 500 to 2000 SLM models
  • 1-1/4 FNPT: 3000 SLM model

Models with the positive shut-off valve option (-P) feature 1/4" welded male VCR fittings. Wetted materials include 303 and 302 SS, FKM, heat cured silicone RTV (rubber), glass-reinforced PPS, heat cured epoxy, aluminum, gold, silicone, and glass. For ranges greater than 250 SLM, 416 SS and nickel replace brass.

Power Supply

Units require 12 to 30 Vdc for models up to 20 SLM (typical supply current 0.250 A) and 24 to 30 Vdc for units 50 SLM and larger (typical supply current 0.75 A).

Key Product Differences

The series includes specific model families distinguished by output configuration, valve integration, and measurement mode:

  • FMA-26XXA Base Models: Standard mass flow controllers with 0 to 5 Vdc input/output and RS232.
  • -I Suffix: Adds optional 4 to 20 mA output (standard remains 0 to 5 V).
  • -I2 Suffix: Provides two 4 to 20 mA outputs.
  • -V2 Suffix: Provides two 0 to 5 V outputs.
  • -IN Suffix: Replaces standard input with optional 4 to 20 mA input.
  • -VOL Suffix: Sets volumetric flow rate as the standard output and control loop setpoint.
  • -P (Valve) Option: Integrates a positive shut-off valve; available on models up to 20 SLM with 1/4" welded male VCR fittings.
  • -T or -P (Output Scale): Alternate secondary output scales for temperature (-T) or pressure (-P).
  • -SCFH Option: Units scaled in SCFH; requires specification of desired range.
  • -TOT Option: Adds a totalizer with 6-digit counter resolution (e.g., liters at 1/100 liter or 1 liter).

The series supports multi-drop configurations allowing up to 26 units on one serial connection over distances of 46 m (150'). Standard calibrations are performed for air @ 5 psig (0 to 1 LPM), 15 psig (2 to 10 LPM), 30 psig (20 to 100 LPM), and 50 psig (200 LPM and greater) at ambient 25°C (77°F).

Accessories

cables

RPL SINGLE 6'8-PIN MINI DIN CB
$78.67 / each
4 In Stock
8-PIN M MINI-DIN SINGLE 25'
$148.81 / each
0 In Stock
8 PIN M MINI-DIN DBL END 25'
$176.50 / each
0 In Stock
8-PIN M MINI DIN DOUBLE 6'
$94.42 / each
1 In Stock
6'' MALE 8PIN DIN CBL TO DB-9
$90.60 / each
0 In Stock
8 PIN M MINI-DIN RIGHT ANGLE
$95.68 / each
0 In Stock

installation hardware

Multi-Drop Box
$424.41 / each
0 In Stock
This item is discontinued. Please contact Technical Sales Team for assistance.
BLACK NYLON THREAD ADPT 10/PK
$10.28 / each
0 In Stock
BLACK NYLON THREAD ADPT 10/PK
$10.31 / each
19 In Stock
NATURAL POLY THREAD ADPT 10/PK
$10.28 / each
0 In Stock
This item is discontinued. Please contact Technical Sales Team for assistance.

meters/controllers

24VDC UNIV PS W/ALL INTER ADPT
$141.63 / each
3 In Stock
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 7ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

What is the minimum inlet pressure for the 0-5 SLPM model?

Asked by: jr454
Thank you for your inquiry. The minimum pressure required is 2 PSI
Answered by: Applications Engineer JJC
Date published: 2024-04-26

Is there an option to prevent electrical noise via user-selectable mitigation level?

Asked by: jmadvint
Thank you for your inquiry. Please compose an email to flow@omega.com and desribe the issue or concern about electrical noise the flow controller may be exposed or currently being exposed and have our Design Team respond.
Answered by: Application Engineer JC
Date published: 2023-10-09

I am interested in using Modbus protocol via RS232 to read data from this instrument. What register address correspond to what type of data (ie Mass flow, Volumetric flow, Pressure and Temperature)?

Asked by: AI70
Thank you for your inquiry. Please refer to the manual that is available for MODBUS communication protocol and is found on the mass flow meter Product Page, FMA-1600A.
Answered by: Applications Engineer JJC
Date published: 2024-02-05

Is this tolerant of 100ppm SO2 or NO2?

Asked by: AGCQ
Thank you for your inquiry. This controller can handle the corrosive gases in question, yet, you will need to purchase the '-LSS' version that is a custom part number which will be chemically compatible.
Answered by: Applications Engineer JJC
Date published: 2023-12-01

Is there another version on serial communication protocol for the FMA-2600 series that does not involve the HyperTerminal?

Asked by: shep25
Thank you for your inquiry! Unfortunately, we do not offer any software with these units and with HyperTerminal not being included in newer Windows versions another program will be needed. Putty may be used as an alternate if HyperTerminal is not available
Answered by: Application Engineer JM
Date published: 2022-06-13

We have a FMA-2616A Mass Flow controller. Can we change the upstream valve configuration to downtream ourselves? Is there an introduction to the relevant operations? Is there a greater risk of damage to the instrument in such operations?

Asked by: herc
Thank you for your inquiry. The mass flow controller can work in vacuum conditions and it is recommended to have it returned via the Customer Care Group at CSReturns@omega.com and request to have the existing controller be used in vacuum conditions. The valve must be physically placed downstream of the flow to control accurately.
Answered by: Application Engineer JC
Date published: 2023-04-17

Do you have the distance from the center of the gas inlet hole to the edge of the device? I can attach a diagram showing which dimensions I need if there is a way to do that

Asked by: AGCQ
Thank you for your inquiry about the mass flow meter. Please forward that picture or drawing to flow@omega.com for the distance you described.
Answered by: Application Engineer JC
Date published: 2023-01-27

Are the FMA-2600 series mas flow controllers rated for vacuum use?

Asked by: joe simon
Thank you for your inquiry about the mass flow controllers. Yes, it can, yet, the valve must be ordered with the valve on the down stream side of the controller and will have a suffix, '-DS.' to reflect. If not found on the website, please email flow@omega.com to request a quote for a controller with the '-DS.'
Answered by: Application Engineer JC
Date published: 2023-04-17
  • y_2026, m_8, d_7, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_8
  • loc_en_US, sid_FMA-2601A, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 13ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration