Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

FMAA2000-Series

Mass Controllers With Or Without Integral Display

Models In Stock
  • ± 1% Accuracy
  • Linear Output
  • Low Cost
  • Thermal Technology
FMAA2000-Series
From $ 977.93
Models In Stock
Mass Controllers With Or Without Integral Display FMAA2000-Series FMAA2000-Series
loading all models
Product Overview
  • Accuracy ± 1 %
  • Accuracy Detail ± 1% of full scale including linearity
  • Additional Features 1 Power Supply Included
  • Calibration NIST 5-Point Certificate
  • Electrical Connection Sub-D Male Miniature Connector
  • Electrical Output 4 to 20 mA, 0 to 5 Vdc
  • Height 6.05 in
  • Leak Rate Under Vacuum less than 10^⁻⁶ cc He/s
  • Length 3.8 in
  • Operating Pressure, Min 0 psi
  • Operating Temperature, Max 50 °C
  • Operating Temperature, Min 0 °C
  • Output Detail Linear 0 to 5 Vdc, 1000 Ω min load, 4 to 20 mA, 500 Ω loop resistance
  • Output Signal Current, Voltage
  • Pressure Coefficient 0.01% FS/psi
  • Process Connection Size 1/4 in
  • Repeatability ± 0.15%
  • Required Pressure, Min 1 psi
  • Response Time 5 sec
  • Series ID FMAA2000-Series
  • Supply Power Note 24 Vdc @ 150 mA, 115 Vac, 220 Vac with AC adaptor
  • Temperature Coefficient 0.05% FS/°C
  • Turndown Ratio 100:1
  • Volumetric Flow Rate, Min 0.01 SCCM
  • Weight 2.75 lb
  • Width 1.5 in

Supported Applications

The Omega FMA-A2000 Series comprises electronic mass flow meters and controllers designed for clean gases. Utilizing capillary-type thermal technology, the series directly measures gas mass flow without requiring temperature, pressure, or square root corrections. The product overview identifies these units as suitable for OEM, laboratory, and process control applications.

Omega calibrates FMA Series instruments to NIST standards for a specific gas and range selected by the customer; K Factors can be used to measure other gases. Engineering units may be displayed in mass units such as Gr/s, LB/H, or Kg/H, or in volumetric units referenced to standard pressure and temperature (e.g., SCCM, SLPM, SCFH). Standard reference conditions are 70°F and 29.92" Hg or 21°C and 760 Torr.

Operating Conditions & Performance

The series operates within an ambient temperature range of 0 to 50°C (32 to 122°F). A warning note specifies a maximum operating temperature of 150 F. Maximum gas pressure ratings are defined by the body material: Polyacetal models support up to 250 psig, while 316 Stainless Steel models support up to 500 psig.

Performance specifications include an accuracy of ±1% of full scale including linearity and a repeatability of ±0.15% full scale or better. The response time is documented as 5 seconds in the series data sheet, while the family manual notes a range of 1-2 second.

Media compatibility covers most non-corrosive gases; users are advised to check wetted materials against specific gas requirements. Capillary mass meters are susceptible to clogging from entrained particulate, and upstream filtration (50 - 100 micron) is recommended if the line or gas contains such contaminants.

Configuration Options

The FMA-A2000 Series offers configurable options across measurement ranges, body materials, display presence, and control functionality. The series supports a wide envelope of flow rates:

  • SCCM Ranges: 0 to 10 SCCM through 0 to 500 SCCM.
  • SLM Ranges: 0 to 1 SLM through 0 to 75* SLM and up to 0 to 100* SLM (FMA-A2100/2300 Series only).

Housing materials are available in Polyacetal or 316 Stainless Steel. Wetted materials include Plastic Model (POM), 316 SS, and 17-4SS for flow bodies. Elastomers are standard FKM with optional Buna, Perfluoroelastomer, or EPDM.

Electrical interfaces utilize a 9-pin sub-D connector. Output signals are available as Linear 0 to 5 Vdc or 4 to 20 mA (with minimum load resistance of 1000 Ω and loop resistance of 500 Ω). Power supply is included, supporting standard 24 Vdc @ 150 mA; optional configurations support 12/15 VDC / 115 or 220 VAC with an AC adapter. A replacement socket plug-in power supply (FMA-200PWA) for 90 to 260 Vac is available as an accessory.

Process connections include a standard ¼" FNPT; stainless steel models feature a ¼" compression fitting. Accessories such as the SSLK-14-14 (316 SS compression fitting ¼ NPT for ¼" OD tube) are offered.

Key Product Differences

The series distinguishes between meters and controllers, with or without integral displays:

  • FMA-A21 Series: Mass flow meter without display. Ranges from 0 to 10 SCCM to 0 to 100 SLM.
  • FMA-A23 Series: Mass flow meter with integral LCD display. Ranges from 0 to 10 SCCM to 0 to 100 SLM.
  • FMA-A22 Series (-SS): Mass flow controller without display, featuring an electromagnetic proportional control valve (normally closed). Available in 316 SS body. Ranges from 0 to 10 SCCM to 0 to 50 SLM.
  • FMA-A24 Series (-SS): Mass flow controller with integral display and control valve. Available in 316 SS body. Ranges from 0 to 10 SCCM to 0 to 50 SLM.

All controller flow ranges specified are for nitrogen or air at 20 psig; a correlation factor is required when used with other gases. For optional 316 stainless steel bodies, the suffix "-SS" is added to the model number (standard on FMA-A22 and FMA-A24 controllers). A 10-point NIST calibration certificate is available by adding the suffix "-NIST10".

Accessories

meters/controllers

FOR 90 TO 260 VAC OUTPUT
$155.35 / each
1 In Stock
Rated 5 out of 5 by from Great for QC or R&D This is our 2nd flow meter of this style. The readings from old one match the new one. Good gage repeatability. Works great for checking air pumps. The display is good when you don't want hook up the analog output. Just keep the water drops away and make sure that you warm it up for 5 minutes.
Date published: 2016-10-04
Rated 5 out of 5 by from ok Everything it's ok with de cudalimeters. We purchased them with shipping to Chile
Date published: 2025-10-10
Rated 5 out of 5 by from Controls and Electrical Engineer It is a nice unit and preforms as described the calibration and accuracy, are spot on.
Date published: 2023-08-24
Rated 5 out of 5 by from Omega FMA-A2300 Very accurate equipment, practical and easy to use
Date published: 2023-07-28
Rated 5 out of 5 by from Reliable Instrument Reliable instrument. Easy to use. Good value too. Great customer service.
Date published: 2023-04-29
Rated 5 out of 5 by from We use these with leak test decay test fixtures Works very well, and comes calibrated ready to use
Date published: 2022-11-03
Rated 5 out of 5 by from This Mass Flowmeters works as descibed Simple to connect. Reliable reading. Recommend it for simple applications.
Date published: 2020-04-06
  • y_2026, m_9, d_10, h_11
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_7
  • loc_en_US, sid_FMA-A2100, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 2ms
  • REVIEWS, PRODUCT

Hello, Is there an interface to communicate with the device through the 9-pin sub-D connector ? I'd like to record the data from the flow meter. Do you have additional doc about that please ? Thanks in advance

Asked by: Bobette
Thank you for your inquiry. Yes, as per the FMA-A2000 series manual, use PINS 3 & 8 for the 4 to 20 mA output OR PINS 4 & 8 for the 0 to 5 voltage output of you choice or preference.
Answered by: Applications Engineer JJC
Date published: 2025-03-29

Hi have a FMA-A2310 unit and when plugged in the display flashes on and off. What could be the problem?

Asked by: Jonchen
Thank you for your inquiry. Please e-mail us at flow@omega.com and we can help you troubleshoot this meter.
Answered by: AS Engineer
Date published: 2020-10-29

Mass flow meters measuring liquids 120 degree's. water glycol. pressure's 800 psi. Up to 1200 psi. Factory aluminum foundry diecasting. CNC machining. Tough factory environment. Would like to talk to a engineer familiar with type engineering experience.

Asked by: Tazzer
Thank you for your inquiry. Unfortunately, Omega's mass flow meters are only for gases, not liquids.
Answered by: Application Engineer JC
Date published: 2023-04-17

Can this flow meter operating with the helium at cryogenic temperatures?

Asked by: Engineer101
Thank you for your inquiry. Unfortunately no. The minimum gas temperature is 32 degrees F.
Answered by: ASE HPO
Date published: 2023-06-05

We have an FMA-A2307 that after it turns on and eventually zeros, drifts between 0.01 to -0.02. We had it calibrated one year ago. When we put a flow on it which ranges from 0 to 0.30 LPM, it takes a while to get to a constant number.

Asked by: bobbygct
Thank you for your inquiry! Yearly calibrations are recommended for these units and if this is a recent development another calibration may be needed. More details may be needed to diagnose this issue. Please contact us at flow@omega.com so that we can troubleshoot this issue.
Answered by: Application Engineer JM
Date published: 2021-12-16

do this FMA-A2310 unit come with calibration certification

Asked by: Ldmc
Yes, NIST calibration certificate is standard.
Answered by: AEHPO
Date published: 2024-11-20

Is the flow meter able to measure flow rates of air at rough vacuum pressures? I'd like to mount it inline with the inlet of a vacuum pump and measure the actual air flow rate the pump is drawing at line pressures around 10 mbar.

Asked by: jman
Thank you for your inquiry about the mass flow meters. Yes, this family of flow meters can measure in a vacuum application/condition and you have sufficient pressure to pull the air thru to measure.
Answered by: Application Engineer JC
Date published: 2023-06-27

are there water mesurements in lbs ?

Asked by: cris
This flowmeter is strictly only for gas flow. Cannot run water through it.
Answered by: AE HPO
Date published: 2023-08-04
  • y_2026, m_9, d_9, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_10
  • loc_en_US, sid_FMA-A2100, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 12ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration