Series-MAO

Manual Analog Override Switch, Alarm

  • Manual override for analog control: The ACI MAO installs between a controller and actuator to provide adjustable manual analog override when needed.
  • Supports two independent outputs: Routes two analog signals in normal operation and allows each output to be switched from automatic to manual independently.
  • Ideal for actuator troubleshooting: Useful for temporary override during controller issues, actuator checkout, linkage testing, and system commissioning.
  • Flexible signal compatibility: Selectable output ranges include 0-5 VDC, 0-10 VDC, 0-15 VDC, and 0-20 mA for common BAS control applications.
  • Alarm feedback during override: Provides an alarm contact output to indicate when manual override is active, helping operators identify overridden equipment.
  • Adjustable field control: Potentiometers allow technicians to vary each manual output signal directly during setup or service.
  • Panel-friendly installation: Compact snap-track mounted board with 45° captive screw terminals supports clean installation in control panels.
  • Reliable interface design: Operates on 24 VAC or 24 VDC power and includes RoHS2 and WEEE approvals for building automation projects.
Series-MAO
From $ 218.00
Manual Analog Override Switch, Alarm Series-MAO Series-MAO
loading all models
Product Overview
  • Accuracy ± 4 %
  • Alarm Note Optional Resistive Alarm Output: 3 Watts or 2A maximum (state resistance value when ordering), Alarm Output Current Rating: 2A maximum
  • Analog Input Note Override Analog Input Voltage Range: 0-24 VDC (Manual Mode); Override Analog Input Current: 2A maximum (Manual Mode); Override Analog Input (Selectable) Range (@ Impedance): 0-5 VDC @ 250Ω minimum 0-10 VDC @ 500Ω minimum 0-15 VDC @ 750Ω minimum 0-20 mA @ 750Ω maximum
  • Analog Output Note Override Analog Output Voltage Range: 0-24 VDC; Override Analog Output Current: 2A maximum or same as override input (Auto Mode)
  • Applications Building and Maintenance, Control Panel
  • Approvals RoHS2, WEEE
  • Control Output NO/NC
  • Height 1.25 in
  • Length 3.75 in
  • Materials PVC
  • Operating Humidity 10 to 95% RH, non-condensing
  • Operating Temperature, Max 120 °F
  • Operating Temperature, Min 35 °F
  • Series ID Series-MAO
  • Storage Temperature, Max 150 °F
  • Storage Temperature, Min -20 °F
  • Supply Current 100 mA
  • Tightening Torque 0.5 Nm (Minimum); 0.6 Nm (Maximum)
  • Weight 0.29 lb
  • Width 3.25 in
  • Wire Gauge 26 to 16 AWG
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 2ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 4ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration