Need assistance? Call us: 1-800-663-4209
DMD-475-Series-Sig-Cond
Isolated Strain Amplifier/Conditioner for Bridge-type Inputs
- 700 V I/O Isolation
- 1100 V Line Isolation
- Power for Four 350 Ohm Load Cells, Fixed 10 V or Variable 5 to 10 Vdc
- Adjustable Gain and Offset
DMD-475-Series-Sig-Cond
From
$
953.35
Product Overview
- Accuracy ± 0.15 %
- Capacitance 60 pF
- Compliance Voltage 20 Vdc
- Current Output 5 mA
- Excitation Voltage Note Voltage Range: 5 to 10 Vdc Current Output: 120 mA max Line and Load Regulation: 0.02% max Output Noise: 1 mVrms max (120 Hz) Temp Coefficient: 60 ppm @ 10V, 100 ppm max
- Gain Range 200 to 2000
- Height 73 mm
- Input Range 5 to 50 mV
- Input Resistance 1000 MΩ
- Input Type Voltage
- Isolation AC Line: 1100 Vrms, 60 pF, Input to Output: 700 Vdc and 60 pF
- Length 96 mm
- Linearity ± 0.005%
- Long Term Stability Temperature: 0.005%/°C
- Operating Temperature, Max 55 °C
- Operating Temperature, Min -25 °C
- Response Time 35 ms
- Response Time Note 10 to 90% = 35 ms
- Series ID DMD-475-Series-Sig-Cond
- Storage Temperature, Max 85 °C
- Storage Temperature, Min -25 °C
- Supply Power 120 Vac
- Supply Power Note 115 Vac ± 10 Vac standard or 220 Vac ± 10% 50/60 Hz optional
- Supply Power Type AC
- Tare Adjustment -3 to 25 mV
- Weight 510 g
- Width 51 mm
- Zero Setting Adjustable Range 0 to 2 V
Supported Applications
The Omega DMD-470 Series consists of AC-powered signal conditioning modules designed for bridge-type sensors, strain gages, and load cells. These isolated amplifiers provide triple-isolated voltage or current outputs to interface with data acquisition systems.
Operating Conditions & Performance
The series accepts input ranges from 5 to 50 mV for a full-scale output of either 0 to 10 Vdc or 4 to 20 mA. Excitation is provided as fixed 10V or variable 5 to 10 Vdc via 6-Wire Bridge Connections. The response time (10 to 90%) is specified at 35 ms.
Operating ambient temperature ranges from -25 to 55°C (-13 to 131°F), with a storage temperature range of -25 to 85°C (-13 to 185°F). Electrical isolation ratings include 1100 Vrms (60 pF) for AC output and 700 Vdc (60 pF) from input to output.
Configuration Options
The DMD-470 Series offers configurable power supplies, output types, and accessories. Both models feature dual zero/tare functions; the tare function allows up to 68% of the input to be offset while maintaining full output span.
Power Supply Options
- 115 Vac ±10 Vac (standard)
- 220 Vac ±10% 50/60 Hz (optional)
- DC powered variants available for specific models
Output Signal Types
- DMD-475: Isolated voltage output, 0 to 10 Vdc
- DMD-476: Isolated current outputs, including 4 to 20 mA and 0 to 20 mA
Accessories
- POWER CORD-SE: Power cord with stripped end termination
Key Product Differences
The series distinguishes between voltage and current output models. The DMD-475 provides a 0 to 10 Vdc voltage output, while the DMD-476 is configured for isolated current outputs (4 to 20 mA or 0 to 20 mA). Model numbers indicate power supply configuration: standard units operate on 120 Vac, with suffixes such as "-220V" denoting 220 Vac operation and "-DC" indicating DC-powered versions. Physical dimensions for the enclosure are 96 L x 51 W x 73 mm H (3.75 x 2 x 2.87") with a weight of 510 g (18 oz).
PDFs & Manuals
Show Ratings & Reviews
Does this allow you to either calibrate and/or shunt the gauge and can you use them in 1/4 and 1/2 bridge mode?
You can use a shunt cal resistor to calibrate this unit. It's is designed for a full bridge input. You would have to complete the bridge externally.
Date published: 2021-07-27