Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

OM-CP-RHTEMP1000IS-Lgr

Intrinsically Safe Temperature and Humidity Data Logger

Models In Stock
  • Certified Intrinsically Safe
  • SGS Certified to meet FM3600 and FM3610 standards
  • Software Battery Life Indicator
  • 316 Stainless Steel Enclosure
OM-CP-RHTEMP1000IS-Lgr
From $ 599.34
Models In Stock
Intrinsically Safe Temperature and Humidity Data Logger OM-CP-RHTEMP1000IS-Lgr OM-CP-RHTEMP1000IS-Lgr
loading all models
Product Overview
  • Additional Features 1 SGS, FM, Intrinsically Safe
  • Battery life up to 2 yr
  • Battery Size and Type Alkaline
  • Calibration Digital calibration through software
  • Data Interface USB
  • Data Interface Note OM-CP-IFC400 or OM-CP-IFC406
  • Materials 316 Stainless Steel/Radel
  • Measurement Type Humidity, Temperature
  • Memory 32767
  • Number of Measurements 2
  • Operating Temperature, Max 80 °C
  • Operating Temperature, Min -40 °C
  • Real Time Recording May be used with PC to monitor and record data in real time
  • Relative Humidity Accuracy ± 3% RH
  • Relative Humidity Accuracy Note 25 %RH to 75 %RH +20 °C to +40 °C (68 °F to 104 °F) Hysteresis Error 1 % typical, 3 % Maximum
  • Relative Humidity, Max 1
  • Relative Humidity, Min 0%
  • Relative Humidity Resolution 0.001
  • Relative Humidity Sensor Type Capacitive Polymer
  • Samples,Max 32768
  • Sampling Rate 1 Hz (1 update/second)
  • Sampling Rate Note 1 reading every second to 1 every 24 hours.
  • Series ID OM-CP-RHTEMP1000IS-Lgr
  • Software Compatibility Windows XP SP3/7/8/10
  • Start Modes Adjustable Delay Start
  • Supply Power Type Battery
  • Temperature Measurement, Max 80 °C
  • Temperature Measurement, Min -40 °C
  • Temperature Measurement Note -40°C to +80°C(-40 °F to +176°F)
  • Temperature Resolution 0.01 °C
  • Temperature Sensor Type RTD
  • Temperature Sensor Type Note Resistance Temperature Detector(RTD)
  • Time Accuracy 16 sec/month
  • Weight 68 g

Supported Applications

The OM-CP-RHTEMP1000IS-A2 is an intrinsically safe temperature and humidity data logger designed for hazardous locations. Its 316 stainless steel enclosure, fast response and intrinsically safe certification make it suited to demanding, potentially explosive environments where both temperature and humidity must be documented.

  • EtO sterilization processes.
  • Environmental studies.
  • Hazardous locations certified as Class 1 Division 1 Group ABCD and Class 1 Division 2 Group ABCD, Temperature Class: T4A.

Operating Conditions & Performance

Temperature is measured by a Resistance Temperature Detector (RTD) and humidity by a Capacitive Polymer sensor over the following ranges:

  • Temperature: -40 °C to +80 °C (-40 °F to +176 °F)
  • Humidity: 0 %RH to 100 %RH (non-condensing)

Temperature resolution is 0.01 °C (0.018 °F) with a calibrated accuracy of ±0.5 °C (0 °C to ±50 °C), ±0.9 °F (32 °F to 122 °F). Humidity resolution is 0.1 %RH with a calibrated accuracy of ±3.0 %RH maximum. The specified accuracy range is 25 %RH to 75 %RH, +20 °C to +40 °C (68 °F to 104 °F) with a Hysteresis Error of 1 % Typical, 3 % Maximum.

The logger holds 32,768 Readings and records at a reading rate of 1 reading every second up to 1 reading every 24 hours, and may be used with a PC to monitor and record data in real time. It is powered by a Tadiran TL-2150 3.6V lithium battery, included and user replaceable in a non-hazardous location, with a battery life of 2 years typical at 15 minute reading rate. Data is date and time stamped in °C, °F, K, °R; %RH, mg/mL, Dew Point, and time accuracy is 16 seconds / month across -40 °C to 80 °C.

The enclosure is 316 Stainless Steel/Radel, measuring 1.67 in x 0.97 in dia. (42.3 mm x 24.6 mm dia.) and weighing 2.4 oz (68 g). The device is not rated for submersion; do not submerge this product to retain the IS rating. Approvals include CE, FM Class 3600, Rev. Jan 2018, FM Class 3610, Rev. Jan 2018, CAN/CSA-C22.2 No. 60079-0:15 and CAN/CSA-C22.2 No. 60079-11:14.

Configuration Options

This series is a single logger configuration, the OM-CP-RHTEMP1000IS-A2, combining an RTD temperature channel and a Capacitive Polymer humidity channel in one intrinsically safe stainless steel housing. Its capabilities and workflow options include:

  • Programmable recording: software programmable immediate or delay start, up to 24 months in advance, with digital calibration through software and calibration date automatically recorded within the device.
  • Process analysis: Sterilization Units and Pasteurization Units lethality equations are available within the software.
  • Data retrieval: the OM-CP-IFC400 docking station connects a single logger by USB cable, while the OM-CP-IFC406 is a 6 Port, Multiplexer docking station for reading multiple loggers.
  • Battery: the OM-CP-BAT113 is the replacement 3.6 V lithium battery, user replaceable in a non-hazardous location.

Key Product Differences

The series is ordered from the following model and accessories:

  • OM-CP-RHTEMP1000IS-A2 - Intrinsically Safe Temperature and Humidity Data Logger.
  • OM-CP-IFC400 - Docking station with USB cable.
  • OM-CP-IFC406 - 6 Port, Multiplexer docking station with USB cable.
  • OM-CP-BAT113 - Replacement 3.6 V lithium battery.

Accessories

accessories

DOCKING STATION/USB CBL/SW CE
$219.44 / each
22 In Stock
MULTIPLEX DL INT-140 SERIES CE
$1,014.99 / each
3 In Stock

consumables

LITHIUM BATTERY 3.6V FOR IS LOGGERS
$34.16 / each
0 In Stock
Rated 5 out of 5 by from Great product This is a great product that provides a quick and easy solution to monitor different environments for any need, ranging from general data collection to in-depth R&D. The probes are pretty resilient and can survive most anything. The only concern from regular usage is making sure the exterior of the probe is clean if going between different environments.
Date published: 2024-03-28
Rated 1 out of 5 by from Microsoft Defender will not allow me to download I purchased three devices and the communicator. I attempted to download the software multiple time with different PC and had the same issue. Tech support had no support for this issue. Can you please look into this issue or at least send a USB stick or CD.
Date published: 2022-09-02
  • y_2026, m_8, d_4, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_US, sid_OM-CP-RHTemp1000IS-A2, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT

When these items fail, are they able to be repaired or do they need to be replaced?

Asked by: Metrology_Manager
Thank you for your question. Yes, they can be repaired, and it would depend on the condition of the logger if needs to be replaced.
Answered by: Application Engineer PV
Date published: 2023-05-19

Is this unit acceptable for use within an MRI room ( magnetic resonance imaging ) ?

Asked by: Joe Mccammitt
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@dwyeromega.com
Answered by: PLVENG
Date published: 2025-01-31

I purchased three of these devices with the communicator and now I can't use them...?

Asked by: Grady
Hello, thank you for your question. We will gladly help you with troubleshooting your specific situation but we will be needing more details. The best way to proceed is to give us a call at 1-800-872-9436 and ask for the Data Acquisition group, or you could also send an email to das@omega.com.
Answered by: DA Engineer
Date published: 2022-09-02

Microsoft Defender will not allow me to download this software. I've tried from multiple PC's with the same outcome. Can you please lok into this issue or offer a download USB or CD when purchasing these devices.

Asked by: Grady
This seems like an isolated issue since all our customers are using the same download link and are not having trouble downloading and installing the software. Please make sure you are logged as the administrator of the computer and you are allowed to make changes to it. If the problem persists, then please direct any further questions to our technical support team at das@omega.com and we will gladly help you resolve this.
Answered by: DA Engineer
Date published: 2022-09-02
  • y_2026, m_8, d_3, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_4
  • loc_en_US, sid_OM-CP-RHTemp1000IS-A2, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 3ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration