Models In Stock
  • Low temperature range: -50 to 250°C (-58 to 482°F)
  • High temperature range: -50 to 450°C (-58 to 842°F)
  • Extreme temperature range: -200 to 600°C (-328 to 1112°F)
  • Corrosion-resistant cast iron protection head
PR-12
From $ 60.26
Models In Stock
Industrial RTD (PT100) Probes with Cast Iron Protection Head PR-12 PR-12
loading all models

Can't find the right model?

Use our custom configurator to fine tune your product

Product Overview
  • Accuracy Class A
  • Additional Features 1 Low Temperature
  • Enclosure Ratings IP67
  • Head Material Cast Iron
  • Nominal Resistance 100 Ω
  • Nominal Resistance Note 100 Ω and 1000 Ω at 0°C standard; TCR = 0.00385 Ω/Ω/°C standard
  • Process Connection Size 1/2 in
  • Process Connection Type NPT Male
  • Protection Head NB1 Cast Iron, Screw Cover, Inside Thread, Standard
  • Series ID PR-12
  • Sheath Material 316 Stainless Steel
  • Shock IEC 60068-2-27; 50g/11ms (15 probes tested together) Duration: 1 day
  • Temperature Coefficient 0.00385 Ω/Ω/°C standard
  • Temperature Probe Style N/A
  • Temperature Sensor Type RTD
  • Vibration IEC 60068-2-6; 5 to 2000 Hz sweep rate, one active per minute; number of sweep cycles 10 and acceleration 5g (15 probes tested together) Duration: 1 day

Supported Applications

The Omega PR-12 series consists of Industrial RTD (PT100) Probes with Cast Iron Protection Heads. These probes are designed for temperature monitoring in industrial processes, specifically for installation into large vessels and tanks as well as large pipes.

Operating Conditions & Performance

The PR-12 series utilizes a PT100 Ω or PT1000 Ω platinum RTD element with a TCR of 0.00385 Ω/Ω/°C standard and nominal resistance of 100 Ω and 1000 Ω at 0°C. The wetted sheath material is 316 stainless steel, housed in cast iron protection heads rated IP67.

Process temperature ranges vary by model family:

  • PR-12L (Low): -50 to 250°C (-58 to 482°F)
  • PR-12H (High): -50 to 450°C (-58 to 842°F)
  • PR-12E (Extreme): -200 to 600°C (-328 to 1112°F)

Accuracy specifications are defined by model:

  • PR-12L: Class A conforming to IEC 60751.
  • PR-12H: Class A from -50 to 300°C (-58 to 572°F); or else Class B.
  • PR-12E: Class A from -100 to 450°C (-148 to 842°F); or else Class B.

The series meets vibration and shock ratings per IEC standards. Vibration compliance is tested at IEC 60068-2-6; 5 to 2000 Hz sweep rate, one active per minute; number of sweep cycles 10 and acceleration 5g (15 probes tested together); Duration: 1 day. Shock compliance is tested at IEC 60068-2-27; 50g/11ms (15 probes tested together); Duration: 1 day.

Response Time by Diameter and Model

T90 response times vary based on probe diameter and model family:

  • PR-12L: 1/8" (2.4 sec), 3/16" (2.8 sec), 1/4" (3.25 sec)
  • PR-12H: 1/8" (2.8 sec), 3/16" (4.11 sec), 1/4" (5.41 sec)
  • PR-12E: 1/8" (9 sec), 3/16" (9.8 sec), 1/4" (10.6 sec)

Configuration Options

The PR-12 series is configurable across several dimensions to meet specific installation requirements.

  • Diameters: Available in 1/8, 3/16, and 1/4 inch.
  • Lengths: Standard probe lengths include 2, 3, 4, 6, 9, 12, 18, and 24 inches. Other lengths may be built using the Omega configurator.
  • Process Connection: All models feature a 1/2" NPT mounting thread for installation in thermowells.
  • Electrical Connection: Includes a screw terminal block for insulated copper extension wire.

The series supports replacement probes (without head assembly) and offers a spring-loading option. The spring-loading feature allows the probe to bottom out in a thermowell, providing quicker and more accurate response.

Key Product Differences

The PR-12 series is differentiated by three primary model families based on temperature range capability:

  • PR-12L (Low): Designed for the -50 to 250°C (-58 to 482°F) process temperature range with Class A accuracy.
  • PR-12H (High): Covers the -50 to 450°C (-58 to 842°F) range, offering Class A accuracy from -50 to 300°C (-58 to 572°F), or else Class B.
  • PR-12E (Extreme): Supports the widest envelope of -200 to 600°C (-328 to 1112°F) with Class A accuracy from -100 to 450°C (-148 to 842°F), or else Class B.

Model numbers follow the convention PR-12 followed by temperature range, element type, diameter, length, and options (e.g., PR-12L, PR-12H, PR-12E).

Rated 5 out of 5 by from Customer Service Parts works well for what is required in plywood mill in the envierment
Date published: 2026-02-23
Rated 5 out of 5 by from Our customers insist on Omega Omega RTDs outlast anything on the market. Our customers insist on Omega
Date published: 2024-09-24
Rated 4 out of 5 by from Great RTD RTD Probe was good. It was just as ordered. That it.
Date published: 2024-08-23
Rated 5 out of 5 by from Good Quality Good quality. As advertised. Will work for our needed application.
Date published: 2023-05-31
Rated 5 out of 5 by from Great product at a great price! Received product faster than expected. Product does what is expected.
Date published: 2022-10-27
Rated 5 out of 5 by from Assembly for Client- Food Processing Parts for an assembly are shipped in a timely manner. Our client enjoys the ease of one part on their shelf as a storeroom item.
Date published: 2022-01-20
  • y_2026, m_8, d_2, h_9
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_6
  • loc_en_US, sid_PR-12E-3-100-1-4-12, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT

Need a wiring diagram for this PR-12E-3-100-1/4-6.

Asked by: Eddy B
There isn't a wire diagram to send so the best thing is to call the Temperature group at 800-872-9436 and have an Engineer explain the connections.
Answered by: ApplicationEngineerANB
Date published: 2024-08-28

What are the dimensions of the cast iron RTD head?

Asked by: bzachry
Hi bzachry, Thank you for the inquiry. For details on the protection head; https://assets.omega.com/pdf/hardware/protection-heads/NB_HEPTX_NXT_HEADS.pdf Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2022-06-21

Is the spring-loaded RTD sealed from the process or is a thermowell required to prevent leaking into the cast iron head? PR-12-2-100-1/4-12-E-SL-DUAL

Asked by: RTDsAreMyFavorite
Thank you for your inquiry. Spring-loaded probes are not sealed and would require a thermowell to seal probe to the process.
Answered by: Application Engineer JB
Date published: 2021-09-15

Are the protection heads certified for any hazardous environments, say Class 1 Div 2. Where can I find information on the heads such as UL Listing?

Asked by: Tom S
Hi Tom S, Thank you for the inquiry. We do not offer assembly rated Class 1 Div 2. For questions on the head alone please forward request to TEMP@OMEGA.COM. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2023-10-07

is this RTD are 2-wire or 3-wire?

Asked by: ankur
Thank you for your inquiry. The PR-12 series RTD is available with either 3 wire or a 4 wire configuration.
Answered by: Application Engineer SP
Date published: 2024-03-19

Good day, what is the max operating pressure ?

Asked by: JHax
Hi JHax, Thank you for the inquiry. We do not provide a pressure rating this probe series due to the temperatures they may be exposed to. For pressurized applications please consider use of thermowell. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2024-07-05
  • y_2026, m_8, d_4, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_6
  • loc_en_US, sid_PR-12E-3-100-1-4-12, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 4ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration