TMIS-HEATER
Incoloy Flanged Immersion Heater Severe Corrosive Solutions
- 3, 5 & 6 Inch, 150 lb (68 kg) Stainless Steel Flange
- Rugged 0.475" Diameter Incoloy Sheath Heating Elements for Use in Severe Corrosive Solutions
- 240 and 480 V, 3 Phase
- 2 to 24 kW
TMIS-HEATER
From
$
6,193.98
Product Overview
- Applications Chemicals
- Enclosure Type General Purpose
- Flange 3 in
- Form factor Flanged Immersion
- Heated Medium Corrosive Fluids
- Hole Diameter 2.54 cm
- Number of Circuits 1
- Number of Heating Elements 3
- Number of Phases 3
- Series ID TMIS-HEATER
- Sheath Diameter 0.475 in
- Sheath Material Incoloy
Supported Applications
The Omega TMIS Series consists of flanged immersion heaters engineered for severe corrosive solutions. These units are designed to handle chemical environments more aggressive than those compatible with standard sheath materials, including heavy solution concentrations ranging from 30% to 50%. The series is specifically intended for applications requiring rugged heating elements capable of withstanding harsh media.
Operating Conditions & Performance
The TMIS Series utilizes a 0.475" diameter Incoloy sheath construction, providing the necessary durability for severe service conditions. The heaters operate at an element loading density of 15 W/in² and are available in power ratings from 2 kW to 24 kW. Electrical supply is configured for 240 V or 480 V, 3 phase operation. Safety compliance includes UL Listed and CSA Certified status when equipped with General Purpose or Moisture Resistant enclosures.
Operational safety requires the use of approved pressure and/or temperature limiting controls to ensure safe function in the event of system malfunctions. The series features heavy-duty jumper straps and terminal posts for electrical connections.
Configuration Options
The TMIS Series offers a configurable envelope defined by flange size, power output, and element count. Key selection parameters include:
- Flange Sizes: 3-inch, 5-inch, and 6-inch stainless steel flanges rated at 150 lb (68 kg).
- Power Ratings: Available from 2 kW up to 24 kW depending on the selected configuration.
- Voltage & Phase: Configurable for 240 V or 480 V, 3 phase systems.
- Element Configuration: Designs include 15 W/in² loading with varying element counts (e.g., 3 elements for the 3-inch flange series).
The model number guide follows the format TMIS-<kW><FLANGE_SIZE>L/*/<PHASE>, where voltage is designated by inserting values such as 240 or 480. Larger flange sizes and kW ratings beyond standard listings are available upon request.
Dimensions & Weight
Overall dimensions vary based on the selected power rating and flange size:
- B Dimension (Length): Ranges from 46 cm to 122 cm (18 1/16 inches to 48 1/16 inches).
- N3 Dimension: Fixed at 2.54 cm (1 inch) across configurations.
- Weight: Varies from 7 kg (16 lb) for lower power units up to 50 kg (111 lb) for high-power models.
Wetted Materials & Construction
The wetted materials consist of an Incoloy sheath and a stainless steel flange. The housing material is specified as Stainless Steel Flange, with the enclosure rated General purpose NEMA 1 (other enclosures available).
Key Product Differences
Variations within the TMIS Series are distinguished by flange diameter and corresponding power capacity:
- 3-Inch Flange Models: Offered in 2 kW, 4 kW, and 6 kW ratings with three Incoloy elements.
- 5-Inch Flange Models: Available in 4 kW, 8 kW, and 12 kW ratings utilizing six Incoloy elements.
- 6-Inch Flange Models: Provided in power steps of 8 kW, 12 kW, 16 kW, 20 kW, and 24 kW with twelve Incoloy elements.
Note: Specific model numbers include suffixes indicating voltage (e.g., /240/3P or /480V/3P) to denote the electrical configuration. The series supports custom configurations for larger flange sizes and higher kW ratings not listed in standard tables.