DPI-AL-Series
i-Series 1/32, 1/16, 1/8 DIN, Temperature/Process Meters with Alarm Outputs
- CE, UL Rated
- Universal Inputs
- High Accuracy
- 2 Relay Alarm Outputs
DPI-AL-Series
From
$
384.33
Product Overview
- Accuracy ± 0.5 °C
- Accuracy Detail ±0.5°C temperature; 0.03% rdg
- Additional Features 1 Programmable 3 Color Display
- Alarm modes Band, High/Low, Latch/Unlatch, Normally Open/Closed, Process/Deviation
- Control Output 2 SPDT Relay
- Current Measurement Range 0 to 20 mA
- Display Type Note None
- Height 48 mm
- Impedance Input 10 MΩ for 100 mV, 1 MΩ for 1 or 10 Vdc
- Input Type Themocouple, RTD, Current, Voltage
- Number of Inputs 1
- Operating Temperature, Max 55 °C
- Operating Temperature, Min 0 °C
- Output Detail Alarm 1 and 2 Outputs Relay: SPDT, 250 Vac or 30 Vdc @ 3 A (resistive load)
- Reading Rate 3 samples/sec
- Relative Humidity 90% RH non-condensing
- RTD Type 100/500/1000 Ω Pt sensor, 2-, 3- or 4-wire; α= 0.00385 or 0.00392
- Sampling Rate 3 Hz (3 updates/second)
- Sensor/Transmitter Power 24 Vdc @ 25 mA
- Series ID DPI-AL-Series
- Temperature Stability RTD: 0.04°C/°C ;Thermocouple @ 25°C (77°F): 0.05°C/°C, cold junction compensation ;Process: 50 ppm/°C ;
- Thermocouple Lead Resistance, Max 100 Ω
- Thermocouple Type J, K, T, E, N, R, S, B, C, L
- Voltage Measurement Range 0 to 100 mV, 0 to 1 V, 0 to 10 Vdc
Supported Applications
The Omega DPi-AL Series comprises temperature and process meters with alarm outputs, designed for universal input measurement in industrial environments. These instruments support thermocouple (ITS 90), RTD (ITS 68), analog voltage, and analog current inputs to monitor process variables directly on the front panel.
Documented applications include:
- Process Measurement: Monitoring temperature via J, K, T, E, R, S, B, C, N, L (J DIN) thermocouples and Pt sensors with 2-, 3- or 4-wire configurations.
- Analog Signal Conditioning: Measuring voltage inputs from 0 to 100 mV, 0 to 1 V, and 0 to 10 Vdc; current inputs of 0 to 20 mA (5 Ω shunt).
- Alarm Monitoring: Providing two relay outputs for high/low, above/below, band, latch/unlatch, normally open/normally closed, and process/deviation alarm operations.
Operating Conditions & Performance
The DPi-AL Series operates within an ambient temperature range of 0 to 55°C (32 to 131°F) with a humidity rating of 90% RH non-condensing. The meters feature front removable and plug connectors for electrical connection.
Performance specifications include:
- Accuracy: ±0.5°C temperature; 0.03% rdg.
- Reading Rate: 3 samples/s.
- Temperature Stability: RTD: 0.04°C/°C; Thermocouple @ 25°C (77°F): 0.05°C/°C with cold junction compensation; Process: 50 ppm/°C.
- Input Impedance: 10 MΩ for 100 mV, 1 MΩ for 1 or 10 Vdc.
- Thermocouple Lead Resistance: 100 Ω maximum.
The series includes a built-in excitation of 24 Vdc @ 25 mA, which is not available with the low power option. Approvals include CE and UL US, backed by a 5 YEAR WARRANTY.
Enclosure Ratings & Dimensions
- 1/8 DIN (DPi8-AL): NEMA 1/Type 1 front bezel; dimensions: 48 H x 96 W x 127 mm D (1.89 x 3.78 x 5").
- 1/16 DIN (DPi16-AL): NEMA 4X/Type 4 (IP65) front bezel; dimensions: 48 H x 48 W x 127 mm D (1.89 x 1.89 x 5").
- 1/32 DIN (DPi32-AL): NEMA 4X/Type 4 (IP65) front bezel; dimensions: 25.4 H x 48 W x 127 mm D (1.0 x 1.89 x 5").
Display Specifications
- 1/8 DIN: Single 4-digit 9-segment LED, 21 mm (0.83”).
- 1/32 and 1/16 DIN: Single 4-digit 9-segment LED, 10.2 mm (0.40”).
Configuration Options
The DPi-AL Series offers configurable power options to suit different installation requirements:
- Standard Power Option: 90 to 240 Vac ±10%, 50 to 400 Hz, or equivalent voltage of 110 to 300 Vdc.
- Low Voltage Power Option: Supports 24 Vac or 12 to 36 Vdc. Note: An external power source must meet safety agency approvals for this option.
The series supports two relay alarm outputs (Alarm 1 and Alarm 2) with the following ratings:
- Relay Type: SPDT, 250 Vac or 30 Vdc @ 3 A (resistive load).
- Configuration: Front panel programmable for high/low, above/below, band, latch/unlatch, normally open/normally closed, and process/deviation modes.
Sensor inputs are configurable across the series to accommodate:
- RTD Input (ITS 68): 100/500/1000 Ω; Pt sensor with 2-, 3- or 4-wire connections and 0.00385 or 0.00392 curves.
- Thermocouple Types (ITS 90): J, K, T, E, R, S, B, C, N, L (J DIN).
Key Product Differences
The DPi-AL Series is distinguished by three physical form factors and two power supply configurations:
- DIN Size 1/8: Models such as DPi8-AL (90 to 240 Vac) and DPi8-AL-DC (12 to 36 Vdc). Features a larger display of 21 mm (0.83”) and NEMA 1/Type 1 front bezel protection.
- DIN Size 1/16: Models such as DPi16-AL (90 to 240 Vac) and DPi16-AL-DC (12 to 36 Vdc). Features a display of 10.2 mm (0.40”) and NEMA 4X/Type 4 (IP65) front bezel protection.
- DIN Size 1/32: Models such as DPi32-AL (90 to 240 Vac) and DPi32-AL-DC (12 to 36 Vdc). Features a display of 10.2 mm (0.40”) and NEMA 4X/Type 4 (IP65) front bezel protection.
All variants include two relay outputs with alarm functionality. The low power option models are identified by the "-DC" suffix in the model number guide, supporting 12 to 36 Vdc or 24 Vac inputs where standard models support universal AC/DC voltage ranges.
PDFs & Manuals
Show Ratings & Reviews
Rated 4 out of
5
by
bobb from
Good Product
Pleased with the product. Easy to program , preforms well.
Shipping is a little slow, and even though I ordered the product from Omega located in Connecticut, the product shipped from California, and had I known this I would have selected a different shipping method.
Date published: 2016-03-29
Rated 5 out of
5
by
jsulzer from
Cost effective and flexible!
Replaced a unit that was damaged due to lightning strike. First one worked for years until millions of volts decided to destroy it. GREAT tech support when the manual and menu was less than obvious.
Date published: 2016-05-23
As a follow-up to the thread about the LCGB-500 load cell, if the DPiS32 is powering the load cell, which port does the shield cable connect to?
There isn't any provision on the DPiS32 to connect the shield from the load cell. You would need to connect it to an external earth ground.
Date published: 2025-01-21
Is the DPiS32 compatible with the LCGB-500 load cell?
Yes, The DPiS32 is compatible with the LCGB-500 load cell. It will both power and read the output signal directly from the load cell. Please note that the DC powered version of the display (DPiS32-DC) does not have the built-in excitation power to drive the load cell. External excitation power would need to be provided to the load cell if you use a DC powered version of this display.
Date published: 2025-01-18
Is it possible to program the output to display a temperature reading directly correlated to the voltage input? (i.e. 2.175 VDC = 500°F or 4.51 VDC = 1000°F)
Yes, it can be done. If you start with the CNI32 or 16 or 8S, for strain, that unit has 10 point linearization and should be able to. However, we would like to better understand the application to confirm this and advise accurately. Please contact our Tech Support to best advise on the application and product recommendations. Thank you.
Date published: 2021-08-10
Can you provide the ethernet cable wiring diagram?
Hi Jerry,
Thank you for the inquiry. Following linked manual provides wiring details of the ethernet cable.
https://assets.omega.com/manuals/M5023.pdf
Best regards
OMEGA
Date published: 2024-10-27
what does - opn mean on the display?
"OPN" on the display of the I Series panel meters means that the input signal is missing. Check wiring to the input to make certain connections are all there and complete and sensors attached are functioning properly. You can also check the INPUT type selected in the menu to make certain that the setting matches the actual input type being applied.
Date published: 2020-01-21
Is this compatible with LC103B-2K load cells?
The CNi/DPi Series controller/displays are not compatible with strain gage based sensors like the LC103B load cells. The CNiS/DPiS variants of this series are compatible with strain gage based sensors but they will only accept a unipolar input signal so you would not be able to use the load cell to measure in both tension and compression. Suggest you look at Platinum Series Controllers/Displays CN32PT,CN16PT,CN8PT,DP32PT,DP16PT and DP8PT.
Date published: 2024-03-01