1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here

OM-CP-HITEMP140-M12-Logger
High Temperature Data Logger With Integral M12 Connector
Models In Stock
- M12 Probe Connector–Quickly Interchange RTD Probes to Fit Your Application
- Measurement Range of -200 to 850°C
- (-328 to 1562°F)
- ± 0.05°C (± 0.09°F) Accuracy
OM-CP-HITEMP140-M12-Logger
From
$
895.00
Models In Stock

Product Overview
- Battery life up to 2 yr
- Battery Size and Type 3.6V Li-ion
- Calibrated Accuracy Temperature Range -200 to 265 °C
- Calibration Digital calibration through software
- Data Interface USB
- Data Interface Note OM-CP-IFC400 or OM-CP-IFC406 USB docking station required; 125,000 baud
- Diameter 24.6 mm
- Electrical Connection M12 4 pin Female
- Enclosure Ratings IP40
- Height 54.5 mm
- Materials, Wetted Stainless Steel
- Measurement Type Temperature
- Memory 43690
- Number of Measurements 1
- Operating Temperature, Max 140 °C
- Operating Temperature, Min -40 °C
- Readings in Trigger Settings Mode 18,724 readings
- Real Time Recording May be used with PC to monitor and record data in real time
- Relative Humidity, Max 1
- Relative Humidity, Min 0%
- Samples,Max 43690
- Sampling Rate 4 Hz (4 updates/second)
- Sampling Rate Note 4 readings per second up to 1 reading every 24 hours
- Software Compatibility XP SP3/Vista/7 and 8 (32-bit and 64-bit)
- Start Modes Adjustable Delay Start, Immediate Start
- Stop Modes Adjustable Delay Stop, Manual Through Software
- Supply Power Type Battery
- Temperature Accuracy ± 0.1 °C
- Temperature Measurement, Max 850 °C
- Temperature Measurement, Min -200 °C
- Temperature Measurement Note 18 to 400 Ω; -200 to 850°C (-328 to 1562°F) (probe dependent)
- Temperature Resolution 0.01 °C
- Temperature Resolution Note 0.0001 Ω; 0.01°C (0.018°F) (probe dependent)
- Temperature Sensor Type RTD
- Temperature Sensor Type Note Pt100 RTD probe with M12 connector (probe sold separately)
- Time Accuracy ± 1 minute/month at 25°C (77°F)
- Weight 85 g
The OM-CP-HITEMP140-M12 is a rugged and versatile high temperature data logger featuring an M12 probe connector. Compatible with a wide variety of M12 RTD probe styles, this data logger is capable of measuring up to 850°C (1562°F) (probe dependent). With the ability to change probes as needed, this device satisfies a multitude of application needs with one powerful data logger versus the need for multiple loggers.
The OM-CP-HITEMP140 data logger has a water tight body enclosure made of food grade stainless steel. It can be placed in environments with temperatures as high as 140°C (284°F) making it suitable for a wide range of applications including autoclave verification, food preparation and processing, environmental studies, well monitoring, washer disinfectors and pasteurization. The OM-CP-HITEMP140-M12 records and stores up to 43,690 time stamped readings and is equipped with non-volatile solid state memory which retains data even if the battery becomes discharged.
Using the OM-CP-HITEMP140-M12 software, starting, stopping and downloading the OM-CP-HITEMP140-M12 is simple and easy. Graphical, tabular and summary data is provided for analysis and data can be viewed in °C, °F, K or °R. The data can also be automatically exported to Excel® for further calculations.
The OM-CP-MULTIMOUNT-Z is a versatile mount or stand for use with the OM-CP-HITEMP140 series of data loggers. It can be used to stabilize a logger inside an autoclave, or screwed to a flat surface to create an anchored base. The OM-CP-MULTIMOUNT-Z is made of stainless steel and is able to withstand temperatures up to 150°C (302°F) making it ideal for use in autoclave sterilization processes.
The OM-CP-ALUCASE-14 and OM-CP-ALUCASE-18 are high quality, multi-purpose briefcases, designed for the protection, transport and storage of data loggers, equipment and accessories. These durable aluminum cases include pick and pluck foam inserts, allowing the user to customize a snug fit and secure any combination of products. The briefcase frame is strong yet surprisingly light weight with a comfortable ergonomically upholstered handle. Two sizes are available: a compact 36 cm (14') width (OM-CP-ALUCASE-14) and large 47 cm (18') width (OM-CP-ALUCASE-18), both featuring an egg crate foam lined lid and keyed locks.
The OM-CP-IFC406 is a multiplexer data logger interface for compatible OM-CP Series data loggers. The OM-CP-IFC406 allows up to six data loggers to be connected into one interface. Up to three OM-CP-IFC406 units may be daisy-chained together to communicate with a total of 18 data loggers through one USB port. To connect multiple OM-CP-IFC406 multiplexer interfaces together, simply join the units side by side, making sure the spring pin contacts are connected and magnetically joined.
The OM-CP-HITEMP140 data logger has a water tight body enclosure made of food grade stainless steel. It can be placed in environments with temperatures as high as 140°C (284°F) making it suitable for a wide range of applications including autoclave verification, food preparation and processing, environmental studies, well monitoring, washer disinfectors and pasteurization. The OM-CP-HITEMP140-M12 records and stores up to 43,690 time stamped readings and is equipped with non-volatile solid state memory which retains data even if the battery becomes discharged.
Using the OM-CP-HITEMP140-M12 software, starting, stopping and downloading the OM-CP-HITEMP140-M12 is simple and easy. Graphical, tabular and summary data is provided for analysis and data can be viewed in °C, °F, K or °R. The data can also be automatically exported to Excel® for further calculations.
The OM-CP-MULTIMOUNT-Z is a versatile mount or stand for use with the OM-CP-HITEMP140 series of data loggers. It can be used to stabilize a logger inside an autoclave, or screwed to a flat surface to create an anchored base. The OM-CP-MULTIMOUNT-Z is made of stainless steel and is able to withstand temperatures up to 150°C (302°F) making it ideal for use in autoclave sterilization processes.
The OM-CP-ALUCASE-14 and OM-CP-ALUCASE-18 are high quality, multi-purpose briefcases, designed for the protection, transport and storage of data loggers, equipment and accessories. These durable aluminum cases include pick and pluck foam inserts, allowing the user to customize a snug fit and secure any combination of products. The briefcase frame is strong yet surprisingly light weight with a comfortable ergonomically upholstered handle. Two sizes are available: a compact 36 cm (14') width (OM-CP-ALUCASE-14) and large 47 cm (18') width (OM-CP-ALUCASE-18), both featuring an egg crate foam lined lid and keyed locks.
The OM-CP-IFC406 is a multiplexer data logger interface for compatible OM-CP Series data loggers. The OM-CP-IFC406 allows up to six data loggers to be connected into one interface. Up to three OM-CP-IFC406 units may be daisy-chained together to communicate with a total of 18 data loggers through one USB port. To connect multiple OM-CP-IFC406 multiplexer interfaces together, simply join the units side by side, making sure the spring pin contacts are connected and magnetically joined.
Software & Drivers
Accessories
accessories
consumables
3.6V High Temperature Replacement Lithium Battery for High Temperature Pressure Data Logger
$111.77
20 In Stock
installation hardware
Show Ratings & Reviews