Need assistance? Call us: 1-800-663-4209
PCL1000-Series
Handheld Multifunction Calibrator w/ Pressure Modules
- Excellent Accuracy ±0.6°C T/C, ±0.3°C RTD 0.015% Electrical 0.05% Pressure
- Read and Source Modes
- 10 T/C Types 8 RTD types plus 400 Series Thermistor
- Stores up to 9 setpoints for each output function
PCL1000-Series
From
$
2,406.79
Product Overview
- Battery life 25 hr
- Battery Size and Type Alkaline AAA
- Continuity Test 0 to 400.0 Ω; audible tone under 10 Ω
- Data Interface RS232
- Frequency CPM: Source 2 to 1000.0; measure 0 to 1000.0,Hz: Source 0 to 1000; measure 0 to 1000.0,kHz: Source 1 to 10.0; measure 0 to 10.00
- Height 221 mm
- Length 58 mm
- Loop Supply Limits Voltage Drive: 1 mA
- Current, Max 0 to 24 mA
- Resistance 3200 Ω
- RTD Input Note RTD Types: JIS, Ni120, Cu10; RTD IEX Range: 0.01 to 3 mA; RTD Frequency Response: 10 ms
- RTD Type Pt 385 (100, 200, 500, 1 kΩ)
- Series ID PCL1000-Series
- Thermistor Type Series 400
- Thermocouple Type J, K, T, E, N, R, S, U, B, L
- Voltage Note Low: 0 to 20.000 Vdc; read and source High: 0 to 250 Vdc or Vac; read only
- Weight 0.9 kg
- Width 107 mm
Supported Applications
The Omega PCL1000 is a high-accuracy multifunction calibrator designed to read and source thermocouples, RTDs, thermistors, voltage, current, frequency, resistance, and pressure signals. It combines the functions of a precision calibrator and multimeter for process device calibration tasks.
Documented measurement types include:
- Thermocouple (Types J, K, T, E, R, S, N, B, L, U)
- RTD (Pt 385: 100, 200, 500, 1 kΩ; Pt 392: JIS, Ni120, Cu10)
- Thermistor (Series 400)
- Voltage and Current
- Frequency (CPM, Hz, kHz)
- Resistance
- Pressure via optional PCL-PM series modules
Operating Conditions & Performance
The unit operates with a power supply of 4 "AA" batteries (included), providing typical battery life of 25 hours. Physical dimensions are 221 H x 107 W x 58 mm D (8.7 x 4.2 x 2.3") and weight is 0.9 kg (1.9 lb). A protective rubber boot is included.
Performance specifications vary by measurement type:
- Voltage Accuracy: ±0.015% rdg Electrical
- T/C Type J Accuracy: ±0.3°C ±10 μV (±0.4°C total)
- RTD Pt100 Accuracy: ±0.1°C ±0.075 Ω (±0.3°C total)
- Resistance Accuracy: 400 Ω: ±0.1 Ω; 3200 Ω: ±1.0 Ω
- Pressure Accuracy: 0.25% FS Pressure (via PCL-PM modules)
- mA Compliance: Up to 1000 Ω load
- Voltage Drive: 1 mA
- RTD IEX Range: 0.01 to 3 mA
- RTD Frequency Response: 10 ms
- Continuity: 0 to 400.0 Ω; audible tone under 10 Ω
Configuration Options
The PCL1000 series supports a broad range of electrical and temperature measurement capabilities with optional pressure expansion.
Measurement Ranges
- Voltage: Low: 0 to 20.000 Vdc (read and source); High: 0 to 250 Vdc or Vac (read only)
- Current: 0 to 24.000 mA
- Resistance: 0 to 400.00 Ω and 400 to 3200 Ω
- Frequency (CPM): Source 2 to 1000.0; measure 0 to 1000.0
- Frequency (Hz): Source 0 to 1000; measure 0 to 1000.0
- Frequency (kHz): Source 1 to 10.0; measure 0 to 10.00
- Pressure: Ranges from 5 to 5000 psig via optional PCL-PM modules, including vacuum, absolute, compound, and differential pressures.
Configuration & Interfaces
- User Interface: Direct keyboard entry with storage of up to 9 setpoints per output.
- Communication: RS232 interface available. Note: Pressure module uses RS232 output; computer connection via RS232 is not possible while a pressure module is connected.
Included Accessories
- Test leads
- Type K thermocouple with cable
- Protective rubber boot
- 4 "AA" alkaline batteries
- Calibration certificate and operator's manual
Key Product Differences
The base model PCL1000 is a high-accuracy multifunction calibrator. Pressure capability requires the addition of specific accessories:
- PCL-PMA: Required pressure module adaptor for connecting PCL-PM modules.
- 700MA: Required adaptor to RS232 port for pressure module communication.
- PCL1000-SCC: Soft carrying case (optional).
The PCL-PM series modules are sold separately and required for pressure applications. The base unit does not include a built-in pressure sensor; it interfaces with external modules via the RS232 port using the specified adaptors.
PDFs & Manuals
Show Ratings & Reviews
In the product image appears a handheld multiprocess calibrator and the product details correspond to a multiprocess calibrator, but the item# is for a pressure module. Is this a multiprocess calibrator or a pressure module?
Thank you for pointing this out. The image and specifications shown are for the PCL1000 Multifunction Calibrator. The part number and pricing indicated are for an accessory pressure input that can be used with this calibrator. This is an error on our our webpage which we will correct
Date published: 2021-01-28