Need assistance? Call us: 1-800-663-4209
GPR-1500
General Purpose or Hazardous Area Certified Industrial PPM Oxygen Transmitter
- Wall mounting 4-20mA loop powered O2 Transmitters
- General Purpose or Hazardous Area certified configurations available
- Trace analyzer can be calibrated in ambient air
Product Overview
- Accuracy ± 2 %
- Calibration Yes
- Calibration Interval 1 to 3 Months
- Data Logging No
- Direct Measurement Range up to 10,000 ppm (1 %)
- Display Resolution 0.01, 2 dp
- Electrical Output RS485 with 4 to 20 mA
- Enclosure Ratings NEMA Type 3R
- Form factor Transmitter
- Housing Material 304 Stainless Steel
- Linearity 0.01
- Measurement Type Oxygen
- Mounting Orientation Wall Mount
- Operating Pressure Range 5 to 30 psi
- Operating Temperature, Max 113 °F
- Output Resolution 0.01 ppm
- Process Connection Size 1/8 in
- Process Connection Type Compression Fitting
- Sensitivity 0.05 ppm
- Series ID GPR-1500
- Supply Power Type Loop Powered
- Supply Voltage 18 to 24 Vdc
- Temperature Compensation Yes
- Volumetric Flow Rate, Max 2 SCFH
- Volumetric Flow Rate, Min 1 SCFH
Supported Applications
The Aii GPR-1500 series comprises PPM Oxygen Transmitters and Analyzers engineered for oxygen analysis in inert, hydrocarbon, helium, hydrogen, mixed, and acid (CO<sub>2</sub>) gas streams. These instruments are designed for general purpose use as well as hazardous area installations requiring specific safety certifications.
The series supports measurement of trace oxygen concentrations across a broad envelope, utilizing electrochemical sensor technology optimized for clean gases and environments containing carbon dioxide or acidic components.
Operating Conditions & Performance
Performance specifications vary by model configuration. The GPR-1500 series offers analysis ranges including 0–10 PPM, 0–100 PPM, 0–1000 PPM, and 0–1% O<sub>2</sub>, with a dedicated 0–25% range available for air calibration. Accuracy is specified as < 2% of full scale (FS) range under constant conditions.
The series provides resolution down to 0.01 PPM and linearity within ±1% or ±2% of FS depending on the specific model variant. Response time varies by configuration: general purpose models achieve 90% of final reading in 10 seconds, while hazardous area certified variants with liquid drain manifolds may require < 2 minutes for 90% response.
Operating temperature ranges differ based on sensor selection:
- GPR sensors: +5°C to +45°C
- XLT sensors (for CO<sub>2</sub>/acidic gases): -10°C to +45°C or -18°C to +45°C depending on the specific hazardous area rating.
Inlet pressure must be regulated to 5–30 psig to deliver a recommended flow rate of 1–2 SCFH. The analyzers are not flow-sensitive within this range but require atmospheric venting.
Configuration Options
The GPR-1500 series is configurable across several dimensions including hazardous area certification, sample conditioning, sensor type, and output signals.
Hazardous Area & Enclosure Options
- General Purpose: Fiberglass NEMA 4X enclosure (6.75 x 8.375 x 4.25 inches).
- Hazardous Area Certified: Models available with cMETus, ATEX, IECEx, and UKEX certifications for Class I, Division 1, Groups C & D or Zone 0/Zone 1 applications.
- Enclosure Ratings: NEMA Type 3R (rain resistant) or NEMA 4X depending on the certification path; housings constructed from fiberglass and painted aluminum.
Sensor & Media Compatibility
- GPR-12-333: Standard PPM sensor for non-acid gas streams.
- XLT-12-333: Designed for gases containing > 0.5% CO<sub>2</sub> or acidic background gases.
- GPR-12-333-H: Optimized for H<sub>2</sub> and He background gases.
- Liquid Drain (LD) Option: Unique liquid drain sensor manifold available on specific hazardous area models to manage condensate.
Outputs & Power
- Analog Output: 4–20 mA or optional 1–5V DC (non-isolated).
- Digital Communication: Optional Modbus RTU communication.
- Power Supply: Configurable for 12–28 VDC, 18–24 VDC (loop powered), or 110–220 VAC depending on the hazardous area certification and model variant.
Sample Conditioning & Accessories
- Inlet Fittings: 1/8" compression tube fittings (general purpose) or 1/4" compression tube fittings (liquid drain models).
- Filtration: Optional A-4442 coalescing filter assembly fitted on the inlet.
- Sample Panels: Automated sample conditioning systems available as separate options.
Key Product Differences
The series distinguishes between general purpose and hazardous area configurations through specific model suffixes and ordering codes. The GPR-1500 base models are 4-wire powered transmitters, while the GPR-1500A variants function as industrial analyzers with expanded output options including Modbus.
Key distinctions include:
- GPR-1500 (General Purpose): Features a fiberglass NEMA 4X enclosure, 1/8" tube fittings, and standard sensor configurations. Response time is typically < 2 minutes for hazardous variants with liquid drain manifolds versus 10 seconds for general purpose models.
- GPR-1500 IS-LD / AIS-LD: Hazardous area certified versions featuring a unique liquid drain sensor manifold, NEMA Type 3R or NEMA 4X enclosures (depending on UL/ATEX path), and specific power requirements such as 18–24 VDC for loop-powered configurations.
- Sensor Selection: The choice between GPR-12-333, XLT-12-333, or GPR-12-333-H sensors dictates compatibility with CO<sub>2</sub>, acidic gases, hydrogen, and helium environments.
- Housing Material: While general purpose models utilize fiberglass NEMA 4X housings, hazardous area variants may employ stainless steel wetted parts within enclosures rated for outdoor or indoor industrial use.
Show Ratings & Reviews
AI_GPR_1500DA-manual-50523.pdf - ai_gpr_1500da_manual_50523_pdf_aii_pdf user manual
AI_GPR_1500AIS-LD-manual-40509.pdf - ai_gpr_1500ais_ld_manual_40509_pdf_aii_pdf user manual
AI_GPR_1500IS-LD-manual-30911.pdf - ai_gpr_1500is_ld_manual_30911_pdf_aii_pdf user manual
AI_GPR_1500N-manual-30806.pdf - ai_gpr_1500n_manual_30806_pdf_aii_pdf user manual
AI_GPR_OxygenAnalyzersFieldServicingGuide-PST-FSG-3015-00.pdf - ai_gpr_oxygenanalyzersfieldservicingguide_pst_fsg_3015_00_pdf_aii_pdf user manual