Need assistance? Call us: 1-800-663-4209
Minox-I-Intrinsically-Safe-Oxygen-transmitter
Electrochemical Galvanic Fuel Cell Oxygen Transmitter for Gas Generation Industries
- The Minox i Galvanic Fuel Cell Oxygen Transmitter is a highly reliable and cost effective, 2-wire, loop-powered transmitter with a 4-20 mA output.
- With a choice of process connections for direct insert or external mounting, the Minox i can be installed in the process or on a sample panel. Using different electrochemical sensing technologies, measurement accuracy and stability are combined with long sensor life in many applications.
Minox-I-Intrinsically-Safe-Oxygen-transmitter
From
$
3,282.00
Product Overview
- Accuracy ± 0.03 %
- Accuracy Detail +/- 0.03 % @ 1 %
- Applications Chemical Refineries, Gases, Pharmaceutical
- Cable Length 1 m
- Diameter 1 59 mm
- Electrical Output 4 to 20 mA
- Enclosure Ratings IP66
- Flow Rate Note Flow-through / extractive: 100 to 500 ml/min (250 ml/min optimal) in a vented atmosphere Direct insertion: Up to 6 m/s
- Gas Measurement Range 0 to 25 %
- Housing Material 316 Stainless Steel
- Lifetime up to 18 mo
- Operating Pressure, Max 1100 mBar
- Operating Pressure, Min 900 mBar
- Operating Temperature, Max 45 °C
- Operating Temperature, Min 5 °C
- Resolution 0.0001
- Sensitivity 0.0005
- Sensor Type Electrochemical
- Series ID Minox-I-Intrinsically-Safe-Oxygen-transmitter
- Shelf Life 6 months
- Supply Power Type DC
- Supply Voltage 24 Vdc
- Weight 800 g
Supported Applications
The Minox i Oxygen Transmitter is an intrinsically safe (I.S), 2-wire, loop-powered device designed to measure oxygen concentration in various industrial processes. It features proven sensor technology for accurate O₂ measurement in demanding applications and hazardous environments. The transmitter supports both electrochemical and solid-state sensor technologies.
Documented application contexts include:
- Hazardous area installations requiring intrinsic safety
- OEM integration via compact footprint and industry-standard electrical plugs
- Gases, vapors, and clean liquids media compatibility (per manual)
- Ventilated atmosphere flow-through or extractive sampling
- Direct insertion applications with velocities up to 6 m/s
Operating Conditions & Performance
The series offers multiple measurement ranges depending on the selected sensor type:
- Solid-state (OC-92): 0...25 % O₂
- Electrochemical (%) (OC-90): 0...25 % O₂
- Electrochemical (ppm) (OC-60, OC-69): 0...10 ppmv, 0...100 ppmv, or 0...1000 ppmv
Accuracy varies by range and sensor type as defined in the specification table:
- 10 ppm: +/- 0.5 ppm
- 100 ppm: +/- 1 ppm
- 1000 ppm: +/- 3 ppm @ 100 ppm
- 25 % range: +/- 0.03 % @ 1 %
Operating temperature ranges differ by sensor technology:
- Solid-state (OC-92): -20 °C...+50 °C (-4 °F...+122 °F)
- Electrochemical (%) and ppm: +5 °C...+45 °C (+31 °F...+113 °F) or -10 °C...+45 °C (+14 °F...+113 °F) for CO2 gases
- Ambient temperature limit for hazardous area certification: -20°C ≤ Ta ≤ +55°C (IECEx, ATEX)
Response time is < 15 seconds @ 25 °C (77 °F) within the selected range. The device operates at a pressure of 900...1100 mBarabs and supports humidity levels up to 0...95 %rh non-condensing.
Configuration Options
The Minox i series is configurable across several dimensions:
- Sensor Types: Solid-state (S-S), Electrochemical %, and Electrochemical ppm sensors are available options.
- Process Connections: Flow-through (1/8" NPT), KF40 flange, or Tri-clamp connections.
- Housing Material: 316 Stainless steel with IP66 (NEMA4) ingress protection.
- Electrical Interface: Industry standard M12 connector; output signal is 4...20 mA loop-powered.
- Power Supply: Requires 24 V DC +/- 10 % with a suitable I.S barrier.
Hazardous area certifications include IECEx (Ex ia IIC T4 Ga), ATEX (Ex ia IIC T4 Ga, Ex ia IIIC T200°C Da), cQPSus (Class 1 Zone 0/Zone 20), and UKEX/JPN Ex classifications.
Key Product Differences
Differences between sensor families are documented as follows:
- Solid-state (OC-92): Measures 0...25 % O₂ with a lower detection limit of 0.05 %. Life expectancy is up to 2 years; shelf life is up to 12 months.
- Electrochemical (%) (OC-90): Measures 0...25 % O₂. Life expectancy is up to 18 months; shelf life is up to 6 months.
- Electrochemical (ppm) (OC-60, OC-69): Measures low-level oxygen in ppmv ranges. Output resolution for CO2 gases is 1 ppmv with a lower detection limit of 1 ppmv. Life expectancy is up to 12 months; shelf life is up to 3 months.
- Dimensions: Overall length varies by connection type: Flow-through (%) measures 129 mm, Flow-through (ppm) measures 100 mm, while KF40 and Tri-clamp versions measure 118 mm. Width is consistently 59 mm across all variants.