Models In Stock
- Monitors Power Status and Up to Eight Switch Closures
- (Dry Contacts)
- Program Up to Eight 20-Digit Phone Numbers
- Works with Telephone Pagers
OMA-VM606-Alarm-Series
From
$
1,899.01
Models In Stock
Product Overview
- Alarm Note Operation: Operates with answering machine on the same phone line; Alarm Notification: Alarm buzzer sounds and alarm relay closes if any input(s) go into an alert condition; Alarm Cancellation: Pushbutton on top of the unit silences the alarm and cancels emergency telephone calls; Alarm Relay Operation: User selectable to be automatically energized during an emergency state (turn off from top button) or to be remotely controlled (turn on or off) via touch tone phone
- Connection Note Telephone Numbers: Stores up to eight callout phone numbers up to 20 digits long; Range of Incoming Rings Before Answer: 1 to 20; Number of Digits of Programmable PIN: 4; Local Identification Message (Unit ID): Record up to an 8-second message that identifies the dialer; Individual Channel Identification Messages: Record up to a 5-second identification message for each input
- Display Type LCD
- Height 127 mm
- Input Type Current, Voltage
- Input Type Note dry_contact
- Length 45 mm
- Materials ABS
- Network and Communications Telephone: Standard RJ11 phone jack connection
- Number of Inputs 8
- Operating Temperature, Max 52 °C
- Operating Temperature, Min 0 °C
- Series ID OMA-VM606-Alarm-Series
- Sound Level 90 dB
- Supply Power Note 120 Vac 50/60 Hz from included wall mount transformer power supply 24-hour rechargeable battery backup
- Supply Voltage 120 Vac
- Time Delay Note Range of Time Delay for Each Input Before Callout: 0 to 999 minutes; Max Power Outage Alarm Time Delay: 900 minutes (default is 5 minutes)
- Weight 1.4 kg
- Width 191 mm
Supported Applications
The Omega OMEGAPHONE® Eight Channel Alarm Dialers (OMA-VM606 series) are alarm systems designed to monitor up to eight switch closures, specifically dry contacts. Documented sensor applications include magnetic door and window switches, thermostats, fluid level switches, and motion sensors.
The system detects deviations from a programmed 'normal' state or power outages exceeding a user-defined delay. Upon activation, the unit sounds an alarm buzzer, closes an alarm relay, and initiates emergency calls to up to eight pre-programmed phone or pager numbers. The OMA-VM606E variant adds Ethernet data collection for remote monitoring and control via TCP/IP/UDP protocols.
Operating Conditions & Performance
The series operates within an ambient temperature range of 0 to 52°C (32 to 125°F). Power is supplied by a 120 Vac 50/60 Hz wall mount transformer, with a built-in rechargeable battery providing up to 24 hours of backup. The unit features two pluggable 12-position terminal blocks for electrical connections and an integral LCD display.
Performance specifications include:
- Inputs: Eight dry contact inputs (5 Vdc, 2 mA source).
- Time Delay Range: Configurable from 0 to 999 minutes per input before callout.
- Power Outage Alarm Time Delay: Maximum of 900 minutes with a default setting of 5 minutes.
- Ringing Detection: Answers incoming calls after 1 to 20 rings.
- Audio Output: A local alarm buzzer rated at 90 dB.
Configuration Options
The OMA-VM606 series is available in two configurations: the standard eight-channel dialer and an Ethernet-enabled model. Both variants support voice programming via touch-tone phone instructions, allowing users to record identification messages without physical access.
- Callout Capacity: Stores up to eight callout numbers, each supporting 20 digits.
- Messaging: Records an 8-second local unit ID message and individual 5-second channel identification messages for each input.
- Alarm Relay Output: SPDT (1 A, 24 Vdc), user-selectable to energize automatically during emergencies or be remotely controlled via touch-tone phone.
- Ethernet Data Collection (OMA-VM606E only): Supports Ethernet LAN connections using RJ45 connectors. The interface supports 10Base-T and 100Base-TX auto-sensing with TCP/IP and UDP transport protocols. LED indicators display link status (Off, Amber for 10 Mbps, Green for 100 Mbps) and activity status.
- Physical Construction: ABS plastic housing measuring 127 H x 191 W x 45 mm D (5.0 x 7.5 x 1.75") with a weight of 1.4 kg (3 lb).
Key Product Differences
The series distinguishes between two primary models based on connectivity options:
- OMA-VM606: Eight channel alarm dialer with a standard RJ11 phone jack connection.
- OMA-VM606E: Eight channel alarm dialer including Ethernet data collection features and an RJ45 connector. This variant is compatible with Omega's Data Capture Software for IP address configuration, network troubleshooting, and communication testing.
The OMEGACARE™ extended warranty program is available as an option to extend the standard 1-year coverage to a total of 2 years when ordered with specific accessories such as OCW-1. The unit operates on the same phone line as an answering machine and includes pushbutton alarm cancellation that silences the buzzer and cancels emergency telephone calls.
PDFs & Manuals
Software & Drivers
Show Ratings & Reviews
Rated 5 out of
5
by
Peck Pierce from
Good Product not so great support
Product is great and does exactly what I wanted, however product support is very difficult to get. Have tried telephone and email with no help.
Date published: 2020-11-04
Unit will respond to PIN for alarm acknowledgment. Any sugestions
Hello
Please send request to das@omega.com so we can assist you further.
Thank you!
Date published: 2020-11-09
Will this work on a digital phone system? i have an VM500-6 that only works on analogs lines.
Hello
This device as well is required to be connected to an analog line.
Date published: 2020-04-24
Hi, I purchased 18 of these auto dialers and we are noticing that there is a delay of about 5-6 seconds when he phone is answered with the time period to the minimum. Is there a way to minimum the time to 2 or 3 seconds?
Thank you for your question. Please direct the issues you are having to our DAS Engr Dept for review. Their e-mail is DAS@OMEGA.COM
Date published: 2020-12-04
Is there a model that works via email with ethernet connection instead of phone?
Thank you for your question. Unfortunately, there is not.
Date published: 2021-12-02