Need assistance? Call us: 1-800-663-4209
EA2-TX-M12
Easidew 2-wire Dew-Point Transmitter
- Measurement ranges -110 up to +20°Cdp
- Dew point or ppm V moisture content output
- Accuracy ±2 °Cdp
- M12 Electrical connection
EA2-TX-M12
From
$
2,622.00
Product Overview
- Accessory Type Flange for 5/8” 18 UNF & 3/4” 16 UNF process connections
- Accuracy ± 2 °C (± 3.6 °F)
- Accuracy Detail ±2°C (±3.6°F) dew point
- Applications Air, Air Dryers, Chemical Refineries, Clean Rooms, Clean Water and Purified Solutions, Compressor Control, Filter Monitoring, Flow Measurement, Gases, HVAC, Industrial and Manufacturing, Natural Gas Compressors, Power Plants & Boilers, R&D/Engineering Testing, Refrigeration, Refrigeration Equipment, Temperature Maintenance, Waste Water Applications
- Calibration Note Traceable 13-point calibration certificate
- Compensated Temperature, Max 50 °C
- Compensated Temperature, Min -20 °C
- Compliance Note ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TR CU @ 0Ex ia IICT4 Ga (-20 to +70 °C) cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Gb, Ex ia IIC T4 Gb Tamb +70 °C
- Dimensions Note M12 5 pin L = 155mm x ø45mm (with connector cable)
- Electrical Connection M12 5 pin Male
- Electrical Output 4 to 20 mA
- Enclosure Ratings IP65
- Factory Setting Sensor fault: 23 mA; Under-range dew point: 4 mA; Over-range dew point: 20 mA
- Flow Rate Note 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion
- Galvanic Isolation KFD2-CR-EX1.20200,KFD2-CR-EX1.30200,KFD0-CS-EX1.50P,KFD0-CS-EX2.50P,KFD2-STC4-EX1.H,MTL5041,MTL5040
- Height 155 mm
- Housing Material 316 Stainless Steel
- Length 45 mm
- Load Resistance Max 250 Ω @ 14 V (500 Ω @ 24 V)
- Operating Pressure, Max 52.5 MPa
- Operating Temperature, Max 60 °C
- Operating Temperature, Min -40 °C
- Repeatability 0.5°C (0.9°F) dew point
- Response Time 5 mins to T95 (dry to wet)
- Series ID EA2-TX-M12
- Storage Temperature, Max 60 °C
- Storage Temperature, Min -40 °C
- Supply Current 23 mA
- Supply Voltage 12 to 28 Vdc
- Weight 150 g
Built for day-to-day use, the Easidew Dew-Point Transmitter (EA2-TX-M12) helps you monitor dew point and moisture levels in industrial and commercial environments. It supports faster troubleshooting when conditions start to drift. It is a good choice for teams that value repeatability and clarity. It helps protect equipment by keeping moisture management visible.
Show Ratings & Reviews