Transmitter-Duct

Duct Transmitters

  • Roof Top Units
  • Supply/Discharge/Return/Mixed Air Temperatures
Transmitter-Duct
From $ 235.00
Duct Transmitters Transmitter-Duct Transmitter-Duct
loading all models
Product Overview
  • Accuracy ± 0.2 %
  • Accuracy Detail < Span of 260ºC: +/- 0.2%, Temp. Spans > 500ºF (260ºC): +/- 0.5%
  • Alloy Material (-) Copper
  • Alloy Material (+) Copper
  • Applications Air and HVAC, Building and Maintenance
  • Electrical Connection Screw Terminal
  • Enclosure Ratings IP10, NEMA Type 1
  • Fitting Polyamide 66 (High Performance Nylon)
  • Insertion Length 12 in
  • Insulation PTFE
  • Lead Length 14 in
  • Operating Humidity 10 to 90% RH non-condensing
  • Operating Temperature, Max 85 °C
  • Operating Temperature, Min -40 °C
  • Output Signal Voltage
  • Probe Diameter 0.25 in
  • Response Time 8 Seconds nominal
  • Series ID Transmitter-Duct
  • Sheath Material 304 Stainless Steel
  • Special Instructions true
  • Special Instructions Note Span Required e.g. (-30 to 130) or (40 to 90)
  • Stability +/- 0.03% after 1000 Hours @ 300ºC (572ºF)
  • Storage Temperature, Max 85 °C
  • Storage Temperature, Min -40 °C
  • Temperature Measurement Range -40 to 85°C
  • Tightening Torque 0.37 ft-lb (0.5 Nm ) nominal
  • Wire Gauge 26 AWG

Supported Applications

The ACI Duct Series is a family of single-point, duct-mounted temperature transmitters built for building automation and HVAC control. Each unit pairs a platinum RTD probe with an integral signal conditioner that delivers a calibrated analog output to a building automation system (BAS) or controller, so duct-air temperature can be read directly by the control loop without a separate signal converter.

The probe is inserted through a 3/8" hole drilled in the duct wall and secured with the supplied enclosure. A foam pad ships attached to every enclosure to seal the mounting surface; on the no-enclosure "DO" option the pad is included but must be installed prior to mounting. The stainless probe and the range of enclosure styles let the same transmitter serve supply, return and mixed-air duct positions across commercial mechanical systems.

Operating Conditions & Performance

The sensing element is a platinum RTD with a positive temperature coefficient (PTC) and a single sensing point, conforming to DIN EN 60751 (IEC 751). The A/TT100 and A/TTM100 build on a 100 Ω nominal element and the A/TT1K and A/TTM1K on a 1 KΩ nominal element, each referenced at 0°C (32°F). Sensor tolerance is Class A, and the sensor operating range spans -40 to 200 °C (-40 to 392 °F) with a nominal response time of 8 Seconds at a 63% step change.

The transmitter is loop powered from +8.5 to 32 VDC (reverse-polarity protected) drawing 25 mA minimum. Maximum load resistance follows the supply: a 250 Ω load needs +13.5 to 32 VDC while a 500 Ω load needs +18.5 to 32 VDC. Output is field-selectable as 4-20 mA (2-Wire loop powered) current or 1-5 VDC or 2-10 VDC (3-Wires) voltage, wired to polarity-sensitive screw terminal blocks accepting 16 AWG to 26 AWG conductors.

Calibrated accuracy is +/- 0.2% for temperature spans under 500°F (260°C) and +/- 0.5% for spans over 500°F (260°C); temperature drift is +/- 0.04%/°F for spans under 100°F (38°C) and +/- 0.02% for spans over 100°F (38°C). The unit operates over an ambient range of -40°F (-40°C) to 185°F (85°C), stores at -40 to 80 °C (-40 to 176 °F), and tolerates 0 to 90% non-condensing humidity. Every transmitter includes Zero and Span adjustments for field calibration and is factory calibrated with NIST-certified equipment.

Configuration Options

The lineup differs first by sensing element: TT100 and matched TTM100 use the 100 Ω element, while TT1K and matched TTM1K use the 1 KΩ element. The matched (TTM) versions are supplied with a defined calibrated span and carry NIST certification points, and the calibrated span may be set anywhere from a minimum of 50°F (28°C) up to a maximum of 500°F (260°C). Matched TTM models cover a range of -45 to 155 °C (-49 to 311 °F).

Output type is a second differentiator: current models provide a 4-20 mA (2-Wire loop powered) signal, while voltage models provide 1-5 VDC or 2-10 VDC (3-Wires). Probe insertion length is selectable at 4", 6", 8", 12" or 18" to suit different duct depths, and each probe uses a 0.250" (6.35mm) 304 Stainless Steel sheath.

Enclosure choice sets the environmental rating and material. The ABS Plastic -PB housing is UL94-HB plenum rated; the Galvanized Steel -GD is NEMA 1 (IP10) rated for -40 to 121 °C (-40 to 250 °F); the Aluminum bell-box -BB is NEMA 3R (IP 14); and the Polystyrene -4X is UL94-V2, NEMA 4X (IP 66).

Key Product Differences

Part numbers follow the pattern A/xx-D-yy-<ENCLOSURE>, assembled from the sensor series, probe length, output signal and enclosure. The sensor series selects the element and matching: TT100 = 100Ω, TTM100 = Matched 100Ω, TT1K = 1KΩ and TTM1K = Matched 1KΩ.

  • Sensor / element: TT100 and TT1K standard elements; TTM100 and TTM1K matched, NIST-certified elements.
  • Probe length: 4", 6", 8", 12" and 18" insertion options.
  • Output signal: current 4-20 mA (2-Wire loop powered) or voltage 1-5 VDC or 2-10 VDC (3-Wires).
  • Enclosure: ABS Plastic (-PB), Galvanized Steel (-GD), Aluminum bell box (-BB) and Polystyrene NEMA 4X (-4X).

Representative catalog part numbers include A/TT100-D-12"-2-GD, A/TT1K-D-18"-4-4X and A/TT100-D-4"-4-BB. Matched TTM100 and TTM1K parts default to a 3 Point NIST certificate; a 5 point certificate can be specified by adding -5PTNIST to the end of any TTM part number.

  • bvseo_sdk, java_sdk, bvseo-4.0.0