DRST-FR-Freq-Sig-Cond

DIN Rail Frequency Input Signal Conditioner | Configurable

Models In Stock
  • Configurable with a standard PC and TXUN-KIT communications unit
  • Pulse Calculator
  • Frequency Generator
  • Galvanic Isolation
DRST-FR-Freq-Sig-Cond
From $ 619.70
Models In Stock
DIN Rail Frequency Input Signal Conditioner | Configurable DRST-FR-Freq-Sig-Cond DRST-FR-Freq-Sig-Cond
loading all models
Product Overview
  • Approvals Note EMC:2014/30/EU, LVD:2014/35/EU
  • Calibration Temperature, Max 28 °C
  • Calibration Temperature, Min 20 °C
  • Electrical Output 0 to 20 mA
  • EMC Standard NAMUR NE 21
  • Enclosure Ratings IP20
  • Frequency Measurement Range 0 to 20 kHz
  • Fuse Rating 400 mA SB / 250 Vac
  • Height 109 mm
  • Isolation 3750 Vac
  • Length 130 mm
  • Linearity Error < 0.1% of span
  • Load Resistance Voltage Output : ≥ 500 kΩ, Current Output : ≤ 600 Ω
  • Mounting DIN Rail 46277
  • Noise Calibration >60 dB
  • Operating Temperature, Max 60 °C
  • Operating Temperature, Min -20 °C
  • Optional Power Note 0 to 999 s
  • Output Value Process
  • Power Consumption 3.5 W, Internal - 3 W
  • Relative Humidity <95% RH
  • Screw Terminal Torque 0.5 Nm
  • Signal Dynamics Output 16 bit
  • Stability Load Stability: ≤0.01% of span/100 Ω
  • Supply Power Type AC/DC
  • Update Rate 20 ms
  • Warm Up Time 1 min
  • Weight 240 g
  • Width 23.5 mm
Advanced Features
• The DRST-FR signal converter can be configured with OMSET software in a standard PC and the TXUN-KIT communications unit.
Application
• The f/I function performs frequency to current and voltage conversion.
• The f/f function can be used for pulse division or multiplication and as a buffer collecting fast pulse trains.
• A scale factor may be entered in all functions. Using both digital inputs, pulse addition or subtraction are possible.
• The frequency generator function is used as e.g. a time base or clock generator.
• Input and supply polarity reversal protection. Current and voltage output signals galvanically separated from the supply and the inputs.
• Programmable digital outputs including NPN, PNP or relay options.
Technical Characteristics
• 5 front LEDs, indicating f1 and f2 active inputs (not NPN), Dig.out.1 and 2 active outputs, and a programmable error signal.
• Analog current output can be configured to any current within 0 to 20 mA range.
• Voltage output range is selectable between 0 to 10 Vdc and 0 to 1 Vdc by use of internal jumpers.
• Input range: Frequency: 0 to 20,000 Hz Sensor types: NAMUR, tacho, NPN, PNP, TTL, S0
• Output range: Current and voltage output: 0 to 20 mA / 0...10 V Relay outputs: 0 to 20 Hz NPN and PNP output as f/f: 0 to 1000 Hz NPN and PNP output as generator: 0 to 20,000 Hz

Accessories

accessories

Communication Tool Kit for TXUN Series and DRST-FR
$453.50
7 In Stock
Rated 5 out of 5 by from Valuable Programmable Signal Converter This product fits our use since it is stable and easy to use.
Date published: 2023-02-28
  • y_2025, m_8, d_28, h_5
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_DRST-FR, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT

Is the TXUN-KIT require for setup?

Asked by: PHoov
Thank you for your question. Yes, it is.
Answered by: Application Engineer PV
Date published: 2021-12-16

Hi, What is the maximum Input Voltage signal ( From Tacho) it can handle? Thanks.

Asked by: Sigi
Thank you for your question. Max. input voltage......................... 80 VAC pp
Answered by: Application Engineer PV
Date published: 2023-12-11

is it possible to take one input signal and condition it into two outputs simultaneously? for example a analog output scaled from 0-5VDC and a conditioned square wave of 10Vpp that matches the input frequency? thank you in advance

Asked by: joel
Hello Joel I'm sorry it does not have that capability, though what you can do is connect the output of the device to a DRSL-SP2 signal splitter and it can split it to two output signals.
Answered by: JA Engineer
Date published: 2020-04-03

Does this model have any shock test certification. other certification /approvals availble

Asked by: Mahendra
Hello, thank you for your question. There are no certifications related to shock as we don't perform that kind of testing for signal conditioners.
Answered by: DAS Engineer
Date published: 2024-05-28

regarding this type, do you have updated &quot;EAC: TR-CU 020/2011&quot; certificate?

Asked by: mikelyg
Thank you for your question. You must send your question to: Omega Engineering - Compliance productcompliance@dwyeromega.com
Answered by: PVLENG
Date published: 2025-08-11
  • y_2025, m_8, d_28, h_5CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_5
  • loc_en_US, sid_DRST-FR, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 29ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration