Product Overview
  • Approvals Note EMC:2014/30/EU, LVD:2014/35/EU
  • Calibration Temperature, Max 28 °C
  • Calibration Temperature, Min 20 °C
  • Electrical Output 0 to 20 mA
  • EMC Standard NAMUR NE 21
  • Enclosure Ratings IP20
  • Frequency Measurement Range 0 to 20 kHz
  • Fuse Rating 400 mA SB / 250 Vac
  • Height 109 mm
  • Isolation 3750 Vac
  • Length 130 mm
  • Linearity Error < 0.1% of span
  • Load Resistance Voltage Output : ≥ 500 kΩ, Current Output : ≤ 600 Ω
  • Mounting DIN Rail 46277
  • Noise Calibration >60 dB
  • Operating Temperature, Max 60 °C
  • Operating Temperature, Min -20 °C
  • Optional Power Note 0 to 999 s
  • Output Value Process
  • Power Consumption 3.5 W, Internal - 3 W
  • Relative Humidity <95% RH
  • Screw Terminal Torque 0.5 Nm
  • Series ID DRST-FR-Freq-Sig-Cond
  • Signal Dynamics Output 16 bit
  • Stability Load Stability: ≤0.01% of span/100 Ω
  • Supply Power Type AC/DC
  • Update Rate 20 ms
  • Warm Up Time 1 min
  • Weight 240 g
  • Width 23.5 mm

Supported Applications

The Omega DRST-FR is a programmable converter designed for industrial applications. The device features a DIN rail mountable housing and is intended for use with hazardous electric voltages.

Operating Conditions & Performance

This series operates on a power supply of 24-230VDC / 24-230VAC. The device includes analog output voltage, analog output current, digital output 1 / relay 1, and digital output 2 / relay 2 capabilities.

Configuration Options

The DRST-FR series supports configurable terminal assignments for inputs, outputs, and power. The device includes status indicators labeled f_in (two instances) and error. Key configuration options include:

  • Housing & Mounting: DIN rail mountable housing according to DIN 46277.
  • Connections: Terminal block connections with a communication connector connected to input terminals.
  • Outputs: Analog output voltage, analog output current, and two digital/relay outputs (digital output 1 / relay 1; digital output 2 / relay 2).
  • Approvals & Safety: CE mark, Double insulation symbol, Ex devices approved acc. to ATEX directive.

The terminal assignments include specific functions for analog ground (Terminal 11), voltage and current outputs (Terminals 12/13), digital grounds and relay contacts (Terminals 21-24), power supply inputs (Terminals 31-33), and sensor input/supply lines (Terminals 42, 52).

Key Product Differences

The series model number guide follows the pattern DRST-FR - <Variant>, with examples including DRST-FR/A and DRST-FR/B. The device must only be connected to the programming unit Loop Link by way of the enclosed cable.

Accessories

accessories

Communication Tool Kit for TXUN Series and DRST-FR
$462.75 / each
7 In Stock
Rated 5 out of 5 by from Valuable Programmable Signal Converter This product fits our use since it is stable and easy to use.
Date published: 2023-02-28
  • y_2026, m_8, d_7, h_9
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_DRST-FR, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT

Is the TXUN-KIT require for setup?

Asked by: PHoov
Thank you for your question. Yes, it is.
Answered by: Application Engineer PV
Date published: 2021-12-16

Hi, What is the maximum Input Voltage signal ( From Tacho) it can handle? Thanks.

Asked by: Sigi
Thank you for your question. Max. input voltage......................... 80 VAC pp
Answered by: Application Engineer PV
Date published: 2023-12-11

is it possible to take one input signal and condition it into two outputs simultaneously? for example a analog output scaled from 0-5VDC and a conditioned square wave of 10Vpp that matches the input frequency? thank you in advance

Asked by: joel
Hello Joel I'm sorry it does not have that capability, though what you can do is connect the output of the device to a DRSL-SP2 signal splitter and it can split it to two output signals.
Answered by: JA Engineer
Date published: 2020-04-03

Does this model have any shock test certification. other certification /approvals availble

Asked by: Mahendra
Hello, thank you for your question. There are no certifications related to shock as we don't perform that kind of testing for signal conditioners.
Answered by: DAS Engineer
Date published: 2024-05-28

regarding this type, do you have updated &quot;EAC: TR-CU 020/2011&quot; certificate?

Asked by: mikelyg
Thank you for your question. You must send your question to: Omega Engineering - Compliance productcompliance@dwyeromega.com
Answered by: PVLENG
Date published: 2025-08-11
  • y_2026, m_8, d_7, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_5
  • loc_en_US, sid_DRST-FR, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 5ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration