Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

Asense-GH

Carbon Dioxide Sensor, Greenhouse, 0-2000 PPM, Temp and Relay, Conformally Coated PCB, with Display

  • Greenhouses
  • Grow Houses
  • Breweries
  • Indoor Agriculture
  • Mushroom Farms & Horticultural
Asense-GH
From $ 1,422.00
Carbon Dioxide Sensor, Greenhouse, 0-2000 PPM, Temp and Relay, Conformally Coated PCB, with Display Asense-GH Asense-GH
loading all models
Product Overview
  • Accuracy ± 30 ppm, ±3 %
  • Accuracy Detail CO2
  • Applications Building and Maintenance, Commercial and Industrial, Environmental Monitoring
  • Approvals RoHS directive 2011/65/EU, EMC 2004/108/EC, 92/31/EEG including amendments by the CE-marking Directive 93/68/EEC
  • Calibration Senseair ABC algorithm (Automatic Baseline Correction)
  • CO2 Measurement Range 0 to 2000 PPM
  • Control Output 1 x SPDT
  • DAC Resolution 10 bits, 10 mV / 0.016 mA
  • Deadband 100 ppm
  • Display Type LCD
  • Electrical Connection Screw Terminal
  • Electrical Output 0 to 20 mA, 4 to 20 mA, 0 to 10 Vdc, 2 to 10 Vdc
  • Enclosure Material ABS, Polycarbonate
  • Enclosure Material Note Box; PC & ABS blend IP65 Rating, Flammability UL94V-0 Cover; Makrolon® 6555 plastic, Flammability rating UL94V-0
  • Enclosure Ratings IP65, UL94 V-0
  • Height 5.95 in
  • Installation 4-6’ o the oor
  • Length 1.85 in
  • Material Construction Option none
  • Measuring Range 7500 sq. ft. maximum
  • Mounting Orientation Industrial Wall Mount - Space
  • Operating Humidity 0 to 95% RH, non-condensing
  • Operating Temperature, Max 122 °F
  • Operating Temperature, Min 32 °F
  • Output Detail Out 1 (CO2): 0/2-10V, 0/4-20 mA, 0-2000 ppm Out 2 (Temp): 0/2-10V, 0/4-20 mA, 32º to 122ºF / 0º to 50ºC Out 3 Relay: N.O.; 1A @ 50 VAC / 24 VDC
  • Power Consumption 3 W
  • Protection PTC fuse (auto reset) on signal return M, short-circuit safe
  • Repeatability ±20 ppm ±1% of measured value
  • Response Time <10 seconds @ 30 cc / minimum flow rate, <3 minutes diffusion time
  • Sampling Time Note Diffusion Time (T1/e): < 3 minutes
  • Series ID Asense-GH
  • Storage Temperature, Max 158 °F
  • Storage Temperature, Min -40 °F
  • Supply Voltage 19 to 29 Vac/Vdc
  • Temperature Measurement Range -4 to 140ºF
  • Trip Point Note 1000 ppm (factory set)
  • Weight 0.812 lb
  • Width 3.33 in
  • Zero Drift ± 10 ppm
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 8ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 25ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration