Product Overview
  • Accuracy ± 30 ppm, ±3 %
  • Accuracy Detail Accuracy is defined after minimum three (3) ABC periods (1 period = 8 days) of continuous operations
  • Applications Air and HVAC, Building and Maintenance
  • Calibration Senseair ABC algorithm (Automatic Baseline Correction)
  • CO2 Measurement Range 0 to 2000 PPM
  • Control Output 1 x SPDT
  • Coverage Area 7500 sq ft
  • Deadband 100 ppm
  • Diagnostics Complete function check, yellow LED; LCD error indication (display model only)
  • Electrical Connection Screw Terminal
  • Electrical Output 0 to 20 mA, 4 to 20 mA, 0 to 10 Vdc, 2 to 10 Vdc
  • Enclosure Material Note Duct Box: PC & ABS blend, Flammability Rating UL94V-0 Cover: Makrolon® 6555 plastic, Flammability Rating UL94V-0 Pipe: PC & ABS blend, Flammability Rating UL94V-0
  • Enclosure Ratings UL94 V-0
  • Height 5.95 in
  • Length 1.85 in
  • Material Construction Option none
  • Measurement Type Carbon Dioxide
  • Measuring Range 7500 sq. ft. maximum
  • Mounting Orientation Duct Mount
  • Operating Humidity 0 to 85% RH, non-condensing
  • Operating Temperature, Max 122 °F
  • Operating Temperature, Min 32 °F
  • Power Consumption 1 W
  • Relay Output 0.5 A @ 125 Vac; 1 A @ 24 Vdc
  • Repeatability ±20 ppm ±1% of measured value
  • Response Time <10 seconds @ 30 cc / minimum flow rate, <3 minutes diffusion time
  • Sensor Life >15 years
  • Sensor Type Single beam infrared sensing technology (NDIR)
  • Series ID Asense-Duct
  • Storage Temperature, Max 122 °F
  • Storage Temperature, Min -4 °F
  • Supply Voltage 19 to 29 Vac/Vdc
  • Temperature Measurement Range -4 to 140ºF
  • Trip Point Note 1000 ppm (factory set)
  • Weight 0.812 lb
  • Width 3.33 in
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 2ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration