Esense-Outdoor-Series

Carbon Dioxide Sensor, 0-2000 PPM, Outdoor Air, 0-10VDC Output, 3 LEDs, Audible Alarm

  • Outdoor or Non-Heated Structures
Esense-Outdoor-Series
From
Carbon Dioxide Sensor, 0-2000 PPM, Outdoor Air, 0-10VDC Output, 3 LEDs, Audible Alarm Esense-Outdoor-Series Esense-Outdoor-Series
loading all models
Product Overview
  • Accuracy ± 30 ppm, ±3 %
  • Accuracy Detail Extended Range Accuracy >2,000 PPM: +/- 30 ppm and +/- 5% of reading
  • Approvals EMC Directive 2014/30/EC
  • Calibration Note Calibration3: Senseair ABC algorithm (Automatic Baseline Correction)
  • CO2 Measurement Range 0 to 2000 PPM
  • Dimensions Note Room Dimensions: (H) 7.62” (193.55 mm) x (W) 4.63” (117.60 mm) x (D) 2.44” (61.98 mm)
  • Display Type N/A
  • Electrical Connection Screw Terminal
  • Electrical Output 0 to 20 mA, 4 to 20 mA, 0 to 10 Vdc, 2 to 10 Vdc
  • Enclosure Material Polycarbonate
  • Enclosure Material Note IP65, Flammability Rating UL94V-0
  • Enclosure Ratings IP65, UL94 V-0
  • Material Construction Option none
  • Mounting Orientation Outside Air
  • Operating Environment Outdoor or Non-Heated Structures
  • Operating Humidity 0 to 95% RH, non-condensing
  • Operating Temperature, Max 115 °F
  • Operating Temperature, Min -22 °F
  • Power Consumption 11 W
  • Repeatability ±20 ppm ±1% of measured value
  • Response Time < 3 minutes diffusion time
  • Sensor Life >15 years
  • Series ID Esense-Outdoor-Series
  • Storage Temperature, Max 122 °F
  • Storage Temperature, Min -4 °F
  • Supply Voltage 24 Vac/Vdc
  • Warm Up Time 1 minutes (@ full specs 15 minutes)
  • Weight 1.4 lb
  • Zero Drift ± 0.3 %

Supported Applications

The ACI eSENSE Outdoor Series is a carbon dioxide (CO₂) transmitter designed for outdoor environments and non-heated structures. The device utilizes Infrared (NDIR) waveguide technology with Automatic Baseline Correction (ABC) to monitor CO₂ levels in ambient air.

Operating Conditions & Performance

The series operates within an ambient temperature range of -22°F to 115°F (-30°C to 46°C). It is rated for humidity from 0 to 95% RH (non-condensing) and features a storage temperature range of -4 to +122 °F. The standard measurement range covers 0 to 2,000 ppm CO₂ with an accuracy of ±30 ppm and ±3% of reading; extended ranges up to 10,000 ppm are available via factory set or SADK Kit with an accuracy of ±30 ppm and ±5% of reading. Repeatability is specified as ±20 ppm ±1% of measured value.

Response time (T₁/ₑ) is < 10 seconds @ 30 cc/min flow rate, or < 3 minutes diffusion time. The sensor life expectancy exceeds 15 years with no maintenance required under normal conditions. Pressure dependence affects the reading by +1.6% per 0.145 psi (1 kPa) deviation from normal pressure.

Configuration Options

The eSENSE Outdoor transmitter is housed in a Poly Carbonate enclosure with an IP65 rating and UL94V-0 flammability classification. The unit includes side ventilation breathers to support outdoor airflow and an integrated heater controlled by an inline thermostat.

  • Heating System: An internal 24 VAC heater activates at temperatures of 39°F (4°C) or below to prevent ice crystal accumulation in the Optical Bench Assembly. Power consumption is <1W for the sensor and up to 10W when heating, with a maximum total power draw of 11W.
  • Outputs: The device provides two analog outputs: Out 1 delivers 0-10 VDC for 0 to 2,000 ppm; Out 2 is configurable for 4-20 mA or 2-10 VDC (also covering the 0 to 2,000 ppm range). Status signals include ERROR and NOT READY states.
  • Power Supply: Requires 24 VAC/VDC ±20% at 50/60 Hz. The input supports half-wave rectified power.
  • Electrical Connections: Utilizes screw terminals rated for 1.5 mm² (0.00232 in²) wire, accommodating power inputs and voltage outputs.

Key Product Differences

The primary model is the ESENSE-OUTDOOR (Item # 135028), which includes the heated outdoor sensor configuration. The series supports extended CO₂ ranges up to 10,000 ppm when configured with a factory set or SADK Calibration Kit (Item # 130502). Custom calibration services are available for IP54 housings only.

Accuracy specifications require the device to complete minimum three ABC periods (where one period equals 8 days) of continuous operation. The Senseair ABC algorithm is standard, though it requires building CO₂ levels to drop to 400 ppm periodically; if a facility operates continuously without this drop, ABC must be disabled.

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 6ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 21ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-NL
en_NL
Save Configuration