Need assistance? Call us: 1-800-663-4209
FLD-Carbon-dioxide-Series
Carbon Dioxide- Direct Read, Panel Mount Variable Area Flow Meters
- Panel-mount variable-area flow meter calibrated for CO₂ service with direct-read scale
- ±5% full-scale accuracy, repeatability ±0.25% and turn-down ratio 10:1
- Rated for up to 200 psi and 121 °C (250 °F) for robust gas process applications
- Wetted parts in 316 SS or anodized aluminum, borosilicate glass flow tube and built-in 6-turn valve
FLD-Carbon-dioxide-Series
From
$
416.58
Product Overview
- Accuracy ± 5 %
- Back Plate 1/8" thick white acrylics
- Float Type Borosilicate Glass
- Mounting Panel Mount
- Number of Tubes 1
- Operating Pressure, Max 200 psi
- Process Connection Size 1/8 in
- Process Connection Type NPT Female
- Process Temperature, Max 121 °C
- Repeatability ± 0.25%
- Scale Direct Read
- Series ID FLD Carbon dioxide-Series
- Turndown Ratio 10:1
- Valve Included true
- Valve Type 6-Turn Valve
Supported Applications
The Omega FLD Series comprises direct read variable area flow meters (rotameters) designed for precise metering of gases and liquids. The series supports applications including the metering of carrier gases in chromatography, indicating and controlling gases in manufacturing processes, liquid and gas measurement in laboratories and pilot plants, as well as general flow and level indication.
Operating Conditions & Performance
The FLD Series operates with a standard accuracy of plus/minus 5% of full scale (FS) and repeatability of plus/minus 0.25%. The useful flow range is defined as a minimum ratio of 10:1, where the minimum flow rate is 10% of the maximum rate shown for each specific model.
Performance limits are established by the following specifications:
- Maximum Operating Pressure: 200 psig/13.8 bars
- Maximum Operating Temperature: 121 C (250 F)
- Process Connections: 1/8 NPT female inlet and outlet connections
The series is calibrated for specific media, including Carbon dioxide (CO2), Air, Water, Nitrogen (N2), Hydrogen (H2), Argon (Ar), Helium (He), and Oxygen (O2). For the FLD Carbon Dioxide subset specifically, available ranges include 1 to 35 L/min and 20 to 200 mL/min for 65 mm tubes, and 100 to 300 mL/min or 10 L/min for 150 mm tubes.
Configuration Options
The series offers configurable dimensions across frame materials, tube lengths, float types, valve options, and mounting styles. Models are grouped by fluid type (e.g., FLDC for Carbon Dioxide), tube length (65 mm or 150 mm), and frame material.
Construction Materials
- Flow Tubes: Heavy walled borosilicate glass with rib-guided or fluted designs for stable readings.
- Floats: Available in glass, red sapphire, 316 stainless steel, carboloy, and tantalum. Suffixes denote material: G (glass), ST (316SS), C (carboloy), SA (red sapphire).
- Frames & Fittings: Aluminum with black anodized finish or 316 stainless steel.
- O-Rings and Packing: Buna O-rings in aluminum/brass models; FKM O-rings in stainless steel meters. Optional perfluoroelastomer and EPR are available.
Housing & Mounting Options
- Standard: Panel mount with side panels (aluminum, black anodized), front shield (polycarbonate resin with longitudinal magnifier lens), back plate (1/8 in thick white acrylics).
- Bench Mounting: Convertible to bench mounting using optional FLTR-1, FLTR-2, or FLTR-3 acrylic tripods featuring built-in spirit levelers and leveling screws.
Valve & Service Options
- Built-in Valves: Standard 6-turn needle valves; optional -HRV suffix for a 16 turn high resolution non-rising stem valve (available on 150 mm meters).
- No Valve: Available with the -NV suffix.
- Oxygen Cleaning: The -02CLEAN suffix indicates oxygen cleaning service.
Key Product Differences
The FLD Series distinguishes models by fluid calibration, tube length, and frame material. Carbon Dioxide specific models (FLDC) are available in 65 mm and 150 mm lengths with stainless steel frames.
- Tube Lengths: Models are offered in 65 mm or 150 mm tube configurations, affecting the maximum flow capacity. For example, FLDC33xx models utilize 65 mm tubes while FLDC35xx models utilize 150 mm tubes.
- Float Suffixes: The model number suffix indicates float material: G for glass, ST for 316SS, C for carboloy, and SA for red sapphire. Some Carbon Dioxide variants also use an 'S' suffix (e.g., FLDC3503S).
- Frame Material: While many FLD models offer aluminum or stainless steel frames, the documented Carbon Dioxide series tables list 316 SS Frame Model Nos. exclusively for these specific fluid calibrations.
Show Ratings & Reviews
Rated 5 out of
5
by
FakeSnake from
I got Flow Control...
Omega always has a great selection of products & technical data so you can find what you need...and this was no exception. The right flow range for the job.
Date published: 2018-12-12
Rated 5 out of
5
by
SLaudano from
Quality Product
Meets our needs as expected. Quality product and excellent delivery.
Date published: 2025-02-10
Rated 5 out of
5
by
IA INSTRUMENTS SAC JOSE U from
Rotameter Flow Meter Dwyer Omega FLDN3505C
Is a good product it flow meter Rotameter from Dwyer Omega
Date published: 2025-02-03
Rated 5 out of
5
by
Wm Ed from
Direct Read Flow Meter
Great flow meter and you cant beat the price. I have bought several of these over the years and they always perform well.
Date published: 2024-10-21
Rated 5 out of
5
by
Welders from
Wonderful product
Wonderful product with exact presision, also has an excellent duration
Date published: 2024-05-31
Rated 5 out of
5
by
Kevork from
Hydrogen Flowmeter
Thank you Omega for custom suppling me the Hydrogen Flow meter, which is not available on the market, in a very short time , even beating the estimated time, one again I can't thank you enough. Kevork
Date published: 2024-04-30
Rated 5 out of
5
by
Natalie Fike from
Flow Meter
Great product for measuring liquid or gas. Comes in handy.
Date published: 2024-04-15
For the product FLDN3305G, the readings are in STANDARD LPM?
Thank you for your inquiry. The FLDN3305G has a range of up to 120mL/min. The units on the scale will be in mL/min.
Date published: 2020-04-29
Where do I reed the ball on the FLDA3214G-NV flow meter. The top or the center?
Thank you for your inquiry about the rotameters. The Rule of Thumb is to read the flow rate at the highest and widest part of the float and in this case, a sphere will be the center.
Date published: 2023-08-15
Hi. Can I assume that all FLD series meters are volumetric, or is there an option to order them so that they are standardized?
Thank you for your inquiry. They are calibrated at standard conditions, yet, no options for a calibration certificate.
Date published: 2024-10-07
Ordered an FLDA3420C-NV rotameter. Per spec sheet it has a max flow of 10 L/min. But now see the website says the units are SCFM and the readings on the meter go to 10. Which is the correct measurement unit?
Thanks for your question?
The part number, FLDA3420C-NV, rota-meter with no valve has been confirmed to have a max flow capacity of 10 LPM.
Date published: 2019-07-15
Is the connection 1/8 pipe size? or 1/8'' Outer Diameter?
Thank you for your inquiry. The process connection is 1/8 inch NPT
Date published: 2024-11-20
Is there an option available that can be sanitized in place using peroxyacetic acid?
Thank you for your inquiry. If you would like to use the acid in question to clean, please consult a Chemical compatibility handbook to determine if the wetted materials are chemically compatible.
Date published: 2025-01-23
Certificate Traceable to NIST
Thank you for your inquiry for this rotameter. Unfortunately, there is no option for a NIST certificate for this series, you may consider the FL-3600, 3700, 3800, and 3900 series.
Date published: 2021-01-26
How do I read the flow meter / take the reading of FLDA3212ST model? Do I read the float at the top, middle or bottom? The model we got is FLDA3212ST
Thank you for your inquiry about the rotameters. The Rule of Thumb is the highest and widest part of the float.
Date published: 2023-03-11