1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here
DBCL-400-120
Portable Dry Block Calibrator with Multiple Well Insert
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Product Specs
<< See all Product Models| Brand |
|
| Accuracy | ± 0.4 °C |
| Accuracy Detail | ±0.4°C (50 to 400°C) ±0.7°F (122 to 752°F) ±0.7°C (400 to 450°C) ±1.3°F (752 to 850°F) |
| Cool-Down Time Note | Cool down 400°C to 100°C: 20 minutes |
| Dimensions Note | 8.75 x 8 x 8 inches/222.25 x 203.2 x 203.2 mm *excluding the carrying strap |
| Display Resolution | 0.1° |
| Frequency | 50/60 Hz |
| Heat-Up Time Note | Heat up time 25° C to 400°C: 12 minutes |
| Height | 222.25 mm |
| Length | 203.2 mm |
| Operating Temperature, Max | 40 °C |
| Operating Temperature, Min | 5 °C |
| Power Consumption | 900 W |
| Probe Wells Details | Depth: 114.3 mm |
| Process Temperature Note | 5°C/9°F above ambient to 450°C/850°F;Temperature Uniformity: 0.020°C at 200°C & 0.030°C at 400°C |
| Process Temperature, Max | 450 °C |
| Process Temperature, Min | 5 °C |
| Relative Humidity Note | Up to 95% relative humidity, non-condensing |
| Relative Humidity, Max | 0.95 |
| Supply Voltage | 120 Vac |
| Temperature Overload Protection | Fan Cooling: Automatic; Overtemperature Limit: 470 °C |
| Temperature Stability | ±0.050°C (50 to 400°C) ±0.090°F (122 to 752°F) (After 15 minutes) |
| Weight | 5 kg |
| Width | 203.2 mm |
| See All Specs | |
Accessories
Insert to accept 1 x 11/16 in and 1 x ¼ in diameter probes
$598.70 / each
2 In Stock
Show Ratings & Reviews
Rated 5 out of
5
by
HCT America from
Staff Compliance Engineer
We recently integrated this Portable Dry Block Calibrator with Multiple Well Insert into our lab’s daily calibration routine, and it has exceeded expectations in both accuracy and usability.
The temperature stability and uniformity are excellent — meeting professional metrology standards while remaining extremely user-friendly and portable. The multiple well insert design is a huge advantage, allowing us to calibrate various probe sizes simultaneously, which saves both time and setup effort during multi-point calibrations.
Build quality feels robust, warm-up time is fast, and the digital control interface is intuitive and responsive. The calibrator maintains consistent performance even under extended use — making it ideal for on-site verification, QA validation, and IEC/ISO 17025 traceable work.
Overall, this unit provides exceptional value and precision. Highly recommended for any lab or engineer who needs a reliable, portable, and accurate dry block calibrator.
Rating: 5/5 — Outstanding performance, efficiency, and design.
Date published: 2025-11-07