Models In Stock
  • Available in multiple lengths: A/GP 2’, 6’, 10’, 20’, 30’, and 40’ harness options give installers flexibility for short panel runs or longer remote pressure sensor locations.
  • Designed for GP Series transducers: These Packard wire harnesses connect directly to ACI GP Series gage pressure transducers for fast, reliable installation.
  • Plenum-rated construction: Each listed harness is plenum rated, making it suitable for commercial building and mechanical-system installations where rated cable is required.
  • Supports 4-20 mA pressure monitoring: Ideal for connecting GP Series loop-powered pressure transducers used in BAS, process control, refrigeration, pumps, hydraulics, compressors, chillers, and boilers.
  • Simplifies field wiring: Preconfigured harness leads help streamline wiring to power supplies, analog inputs, and grounding connections.
  • Improves installation flexibility: Separate harness ordering allows the same GP pressure transducer platform to be matched with the cable length best suited for each job.
  • Built for demanding applications: Supports GP transducers used with compatible gases and liquids including refrigerants, glycol, water, hydraulic fluid, diesel, nitrogen, hydrogen, and air.
  • Reliable accessory solution: Purpose-built ACI harnesses help complete GP pressure transducer installations while maintaining compatibility with the sensor’s Packard connector design.
Harness
From $ 41.00
Models In Stock
Cable Harness Harness Harness
loading all models
Product Overview
  • Applications Boilers, Building and Maintenance, Commercial and Industrial, Environmental Monitoring, Flow Measurement, Fluid Measurement and Control, Industrial and Manufacturing, Pneumatic Systems, Process Automation and Control, R&D/Engineering Testing, Refrigeration Equipment
  • Cable Material PVC
  • Electrical Connection Pigtail Leads
  • Operating Temperature, Max 257 °F
  • Operating Temperature, Min -40 °F
  • Series ID Harness
  • Storage Temperature, Max 176 °F
  • Storage Temperature, Min -40 °F

Supported Applications

The A/GP Harness is a Packard wire harness that connects the GP Series pressure transducers to their power supply and signal loop. Because the GP Series transducers use a Packard connector, this harness provides the mating cable assembly that carries the transducer's 4 to 20 mA (2-wire, loop-powered) output to a controller, indicator, or data acquisition system.

Offered in plenum-rated and metal-clad constructions, the harness suits the same commercial, industrial, and process-control installations as the transducers it serves — refrigeration, pumps, hydraulics, compressors, and general pressure monitoring. The plenum-rated versions are well suited to routing through air-handling spaces, while the metal-clad versions add physical protection for more demanding runs.

The A/GP Harness must be ordered separately when ordering transducers with a Packard connector, allowing the cable length to be matched to the distance between the sensor and the control point.

Operating Conditions & Performance

The harness is a direct-mating Packard connector cable assembly built to carry the transducer's 4 to 20 mA (2-wire, loop-powered) signal. When wired for 4 to 20 mA output, the black wire is not used.

Two construction grades are available:

  • Plenum Rated: the standard A/GP Packard wire harness, offered in lengths from 2' up to 40'
  • Metal Clad: the A/GP M-series harness for added mechanical protection, offered in 10' and 20' lengths

Each harness terminates in the Packard connector that mates directly with the GP Series transducer, so no field wiring of the sensor-side connection is required.

Configuration Options

The lineup differs in two respects: cable length and jacket construction. Length is selected to span the exact distance from the transducer to the controller without excess cable, ranging from a short 2' lead up to a 40' run. Jacket construction is either plenum-rated (the standard A/GP harnesses) or metal-clad (the A/GP M-series), letting the installer choose between air-handling-space compliance and rugged physical protection.

Every variant is otherwise identical in function — a Packard wire harness that connects to the GP Series transducer — and each length carries a correspondingly higher shipping weight, from A/GP 2' Harness at 0.09 lbs. (0.04 kg) up to A/GP 40' Harness at 1.22 lbs. (0.55 kg).

Key Product Differences

The series comprises six plenum-rated lengths and two metal-clad lengths, each with its own catalog item number:

  • A/GP 2'HARNESS (Item #142606) — A/GP 2' (0.61m) Packard Wire Harness, Plenum Rated
  • A/GP 6'HARNESS (Item #135614) — A/GP 6' (1.83m) Packard Wire Harness, Plenum Rated
  • A/GP 10'HARNESS (Item #116601) — A/GP 10' (3.05m) Packard Wire Harness, Plenum Rated
  • A/GP 20'HARNESS (Item #135613) — A/GP 20' (6.10m) Packard Wire Harness, Plenum Rated
  • A/GP 30'HARNESS (Item #135703) — A/GP 30' (9.14m) Packard Wire Harness, Plenum Rated
  • A/GP 40'HARNESS (Item #136995) — A/GP 40' (12.19m) Packard Wire Harness, Plenum Rated
  • A/GP M10'HARNESS (Item #147878) — A/GP 10' (3.05m) Harness, Metal Clad
  • A/GP M20'HARNESS (Item #147881) — A/GP 20' (6.1m) Harness, Metal Clad

All lengths share the same Packard connector interface to the GP Series transducer; only the cable length and jacket construction vary.

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 4ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration