Need assistance? Call us: 1-800-663-4209
Q5-B5-Series
BACnet MSTP, Smart Sensor, 3 SPDT Relays, NEMA 4X
- Mechanical Rooms
- Warehouses
- Refrigeration Plants
- Industrial Plants
- Process Monitoring
- Leak Detection
- Parking Garages
- Auto/ Truck Maintenance Facilities
- Oil and Gas Industry
Q5-B5-Series
From
$
99.00
Product Overview
- Applications Access and Parking Control Systems, Air and HVAC, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment
- Approvals RoHS, cETLus Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204)
- Baud Rate Note Q6 Communication Baud Rates (Q5): 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800)
- Buzzer 80 dB at 3.94" (10 cm), 2700 Hz (3 Programmable Tones)
- Cable Type Insulated Shielded
- Calibration Note Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly
- Conduit Connection 3/4 in Knockouts
- Electrical Connection Screw Terminal
- Electrical Life 200,000 operations minimum at rated load
- Enclosure Material Note Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66)
- Enclosure Ratings IP66, NEMA Type 12, NEMA Type 13, NEMA Type 4, NEMA Type 4X, UL94 V-0
- Fuse Rating 0.75 A Polyswitch
- Keypad 3 Capacitive Touch sensing keys
- LED Indicators Two Green LEDs (Tx/Rx Communication Status): Three LEDs (Relays 1, 2 & 3)
- Mechanical Life 50 million operations
- Operating Environment Indoor use only
- Operating Humidity 5 to 95% RH, non-condensing
- Operating Temperature, Max 122 °F
- Operating Temperature, Min 32 °F
- Output Detail Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires)
- Power Consumption 8.4 VA
- Sensor Type Infrared
- Series ID Q5-B5-Series
- Service Life Electrochemical (Toxic): 2 to 3 Years, typical
- Shelf Life 6 months
- Storage Temperature, Max 68 °F
- Storage Temperature, Min 32 °F
- Supply Current 0.3 A
- Tightening Torque 0.37 ft-lb (0.502 Nm) Nominal
- Warm Up Time 24 Hours (Allow 24 hours before calibrating sensor after installation)
- Weight 1 lb
- Width 3.54 in
- Wire Gauge 24 to 16 AWG
PDFs & Manuals
Accessories
Show Ratings & Reviews