Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

OM-CP-HITEMP140-Series

Autoclave Temperature Data Logger

Models In Stock
  • Rugged stainless steel design, submersible (IP68), and withstands up to 140°C (284°F).
  • Stores up to 32,700 readings with date and time stamps for reliable logging.
  • High-precision readings with ±0.1°C (0.18°F) accuracy
  • User-replaceable battery for easy maintenance and long-term use.
OM-CP-HITEMP140-Series
From $ 791.03
Models In Stock
Autoclave Temperature Data Logger OM-CP-HITEMP140-Series OM-CP-HITEMP140-Series
loading all models
Product Overview
  • Battery life up to 1 yr
  • Form factor Handheld
  • Measurement Type Temperature
  • Number of Measurements 1
  • Probe Diameter 4.8 mm
  • Relative Humidity Accuracy ± 3% RH
  • Relative Humidity, Max 1
  • Relative Humidity, Min 0%
  • Series ID OM-CP-HITEMP140-Series
  • Supply Power Type Battery

Supported Applications

The OM-CP-HITEMP140 is a rugged, high precision temperature data logger designed for use in harsh environments. It is a submersible stainless steel device capable of withstanding temperatures up to 140°C (284°F), with an accuracy of ±0.1°C (0.18°F) over its operating range, and it can store up to 32,700 readings.

With a rigid external probe and a submersible IP68 body, the logger is a natural fit for autoclave verification and mapping, sterilization studies, and other wet or high-temperature processes where the recorder must be placed directly in the load.

Operating Conditions & Performance

The logger uses a 100Ω Platinum RTD, measuring -40 to 140°C (-40 to 284°F) at the body and -200 to 260°C (-328 to 500°F) at the probe, with a resolution of 0.01°C (0.02°F) and a calibrated accuracy of ±0.1°C (±0.18°F) [20 to 140°C (68 to 284°F)].

  • Memory: 32,700 readings.
  • Reading rate: one second up to once every 24 hours.
  • Enclosure rating: IP68.
  • Humidity: 0 to 100% RH.
  • Power: 3.6V high-temperature lithium battery (included; user-replaceable).
  • Battery life: 1 year typical [1 minute reading rate at 25°C (77°F)].

The logger body measures 48 H x 25 mm D (1.9 x 0.97") in 316 stainless steel and weighs 120 g (4.2 oz). Start modes include software programmable immediate start and delay start up to eighteen months in advance, calibration is performed digitally through software, and the calibration date is automatically recorded within the device. The logger carries CE with optional NIST calibration and requires the OM-CP-IFC400 USB docking station for operation.

Configuration Options

The series shares one logger body, sensor, and memory across every model; the models differ in the length of the rigid external probe and in whether a thermal shield is fitted.

Probe length

The base OM-CP-HITEMP140 carries a 50 mm (2") probe. Shorter and longer options are offered: the OM-CP-HITEMP140-1 uses a 25 mm (1") probe, the OM-CP-HITEMP140-5.25 uses a 131 mm (5.25") probe, and the OM-CP-HITEMP140-7 uses a 175 mm (7") probe. Longer probes reach deeper into a load or vessel while the logger body stays outside the hottest zone.

Thermal shield (TSK)

The TSK configurations enclose the logger in a PTFE thermal shield rated for a time-limited -200 to 250°C (-328 to 482°F) operating environment. The shield measures 110 x 51 mm dia. (4.3 x 2.0") and weighs 274 g (9.7 oz) not including the data logger, extending the survivable ambient exposure of the selected probe length.

Key Product Differences

The model lineup consists of the following probe-length and thermal-shield configurations:

  • OM-CP-HITEMP140 — high temperature data logger with 50 mm (2") probe.
  • OM-CP-HITEMP140-1 — high temperature data logger with 25 mm (1") probe.
  • OM-CP-HITEMP140-5.25 — high temperature data logger with 131 mm (5.25") probe.
  • OM-CP-HITEMP140-5.25-TSK — 131 mm (5.25") probe logger with thermal shield.
  • OM-CP-HITEMP140-7 — high temperature data logger with 175 mm (7") probe.
  • OM-CP-HITEMP140-7-TSK — 175 mm (7") probe logger with thermal shield.
  • OM-CP-HITEMP140-TSK — OM-CP-HITEMP140 data logger with thermal shield.

Each configuration is also available with a NIST certificate (-CERT).

Rated 4 out of 5 by from Hi temp data logger The unit works as very well. Only issue is the directions. they are all online and incomplete so it is trial and error until you figure out how to operate to unit.
Date published: 2018-01-17
Rated 4 out of 5 by from Excellent applicability For price and accuracy both effectively combined in this products.
Date published: 2015-12-16
  • y_2026, m_8, d_3, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_US, sid_OM-CP-HITEMP140, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT

What is the name of the USB driver that should be installed in order for the interface cable to work? https://www.omega.co.uk/software/

Asked by: bleu
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM”
Answered by: Application Engineer PV
Date published: 2021-09-01

Does it work for surface applications?

Asked by: AngEx
Hello, thank you for your question. Technically, this unit was not design for surface applications and we may have better options to offer. If you can please give us a call at -800-872-9436 and ask for the Data Acquisition team. We will gladly help you find the best solution for your particular application.
Answered by: DA Engineer
Date published: 2022-03-08

Do you have updated software? Received this error when trying to download software. <Error> <Code>AccessDenied</Code> <Message>Access Denied</Message>

Asked by: RickName
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM
Answered by: Application Engineer PV
Date published: 2023-07-06

Can a specific NIST certification temperature be requested? Our documentation requires certification at temperature of use (121C).

Asked by: Alicia
Thank you for your question. You will need to contact our Customer Service Dept at 1-800-622-2378 or CSERVICE@OMEGA.COM and they will advise if custom calibration is available.
Answered by: Application Engineer PV
Date published: 2022-08-12

My data logger stops recording on its own but it is set to stop manually. Why is this happening?

Asked by: sp18
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM
Answered by: Application Engineer PV
Date published: 2023-01-18

Hello! I have a data logger Hitemp 140 and I think maybe the batery is over. How can I change it? Do I need to send for somewhere?

Asked by: Anonymous
Please send request to das@omega.com for further assistance.
Answered by: JA Engineer
Date published: 2023-03-14

hi is this datalogger support 360F ? i need check 100 F ,200 F, 300 F, and 360 max, this equipment support that temperatures in autoclave? regards

Asked by: Anonymous
Hello The logger can be capable of monitoring 482 deg F at up to 32 minutes with the optional thermal shield (add '-TSK' at the end of the part number).
Answered by: JA Engineer
Date published: 2022-09-07

Having an issue downloading drivers due to requesting administrative rights which I am listed as administrator? Cam you assist?

Asked by: Crashcuz
Hi Crashcuz, Thank you for the inquiry. Please forward this request to DAS@OMEGA.COM Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2022-05-13
  • y_2026, m_8, d_4, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_14
  • loc_en_US, sid_OM-CP-HITEMP140, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 38ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration