Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

OM-USB-TC-Series

8-Channel Thermocouple/Voltage Input USB Data Acquisition Modules

This item is discontinued. Please contact Engineering for alternatives or questions

  • OM-USB-TC and OM-USB-5201 Have 8 Thermocouples Inputs
  • OM-USB-TC-AI Has 4 Thermocouple Inputs and 4 Analog Voltage Inputs
  • OM-USB-5201 Has Data Logging Capability (Compact Flash)
  • 24-Bit Resolution
OM-USB-TC-Series
From $ 618.26
8-Channel Thermocouple/Voltage Input USB Data Acquisition Modules OM-USB-TC-Series OM-USB-TC-Series
loading all models
Product Overview
  • Accuracy ± 0.25 °C
  • Configuration Parameters Pull-Up/Down Configuration, User-Configurable Input/Output
  • Data Interface USB 1.1, USB 2.0
  • Digital Input Digital: Low = –0.5 to 0.8 Vdc
  • Electrical Connection Screw Terminal
  • Frequency Input Range 1 MHz
  • Height 36 mm
  • Input Configuration Connected Software
  • Input Type Note Thermocouple: J, K, T, E, R, S, B, N
  • Input Voltage Note Absolute Maximum Input Voltage: Thermocouple Inputs; ±25V (Power On), ±40V (Power Off): Voltage Inputs; ±25V (Power On), ±15V (Power Off)
  • Isolation Power Isolation: 500 Vdc minimum measurement system to PC, Input Isolation: 500 Vdc min between field wiring and USB interface
  • Length 127 mm
  • Operating Temperature, Max 50 °C
  • Operating Temperature, Min 0 °C
  • Pull-down Resistor GND
  • Pull-up Resistor 47 kΩ
  • Relative Humidity 0 to 90% RH non-condensing
  • Sampling Rate 2 Hz (2 updates/second)
  • Series ID OM-USB-TC-Series
  • Storage Temperature, Max 85 °C
  • Storage Temperature, Min -40 °C
  • Supply Voltage 5 Vdc
  • USB Cable Length 3 m
  • Warm Up Time 30 min
  • Weight 182 g
  • Width 89 mm
  • Wire Gauge 30 to 16 AWG

Supported Applications

The Omega OM-USB-TC Series comprises USB 2.0 full-speed data acquisition modules designed for thermocouple and analog voltage input measurements in Microsoft® Windows® environments. The series includes the OM-USB-TC, which provides eight differential thermocouple inputs; the OM-USB-TC-AI, configured with four differential thermocouple inputs and four differential or single-ended voltage inputs; and the OM-USB-5201, an 8-channel thermocouple module featuring integrated data logging via CompactFlash. These standalone, plug-and-play modules support Type J, K, R, S, T, N, E, and B thermocouples.

Operating Conditions & Performance

The series operates within an ambient temperature range of 0 to 50°C (32 to 122°F) with a humidity rating of 0 to 90% RH non-condensing. Storage conditions are specified as -40 to 85°C (-40 to 185°F). The modules feature 24-bit resolution and require a warm-up time of 30 minutes maximum for optimal performance.

Measurement ranges vary by thermocouple type:

  • Type J: -210 to 1200°C (-346 to 2192°F)
  • Type K: -210 to 1372°C (-346 to 2502°F)
  • Type T: -200 to 400°C (-328 to 752°F)
  • Type E: -200 to 1000°C (-328 to 1832°F)
  • Type R and S: -50 to 1768°C (-58 to 3214°F)
  • Type B: 250 to 1820°C (482 to 3308°F)
  • Type N: -200 to 1300°C (-328 to 2372°F)

The OM-USB-TC-AI model supports analog voltage inputs with ranges of ±10V, ±5V, ±2.5V, and ±1.25V.

Configuration Options

The series offers configurable input types, data logging options, and digital I/O capabilities across its models:

  • Sensor Inputs: Supports 8 differential thermocouple channels (OM-USB-TC, OM-USB-5201) or a mix of 4 thermocouple and 4 voltage inputs (OM-USB-TC-AI).
  • Digital I/O: All models include eight independent, TTL-compatible digital input/output channels that are software programmable.
  • Data Logging: The OM-USB-5201 includes a 512 MB CompactFlash card for standalone logging at intervals from 1 second up to 2^32 seconds. Data logging requires the module to be disconnected from the computer and powered by an external AC adapter.
  • Counter Input: The OM-USB-TC-AI includes a single event counter with TTL, rising edge triggered input (up to 1 MHz frequency).
  • Cold Junction Compensation: Integrated CJC sensors provide accuracy of ±0.25°C typical and ±0.5°C max at 15 to 35°C.

The modules feature screw terminal blocks accepting 16 to 30 AWG wire, with input isolation rated at a minimum of 500 Vdc between field wiring and the USB interface.

Key Product Differences

Differences among series members are defined by channel configuration and data logging capability:

  • OM-USB-TC: An 8-channel thermocouple input module powered solely via the USB port.
  • OM-USB-TC-AI: A hybrid model with four thermocouple inputs and four analog voltage inputs. It also includes a counter output feature not present in other models.
  • OM-USB-5201: An 8-channel thermocouple module equipped for data logging via CompactFlash, requiring an external AC adapter (included) when operating independently of the USB host power.

The OM-USB-TC and OM-USB-TC-AI weigh 182 g (6.4 oz), while the OM-USB-5201 weighs 227 g (8.0 oz). All models utilize a plastic housing with dimensions of 127 L x 89 W x 36 mm H (5.0 x 3.5 x 1.4").

Accessories

accessories

USB POWER ADAPTER 2.5-WATT
$57.05 / each
2 In Stock
PRO SOFTWARE FOR OMB-DAQ-2416
$384.02 / each
0 In Stock
DASYLab Data Acquisition System
$2,324.11 / each
0 In Stock
Rated 5 out of 5 by from Works as intended. Software works as intended. Simple to use interface and data logging.
Date published: 2016-03-21
Rated 5 out of 5 by from Great Device Amazing instruments. We leverage the TC and digital channels of three of these devices to characterize the thermal performance and safety-thermostat-trip points in our line of clothes dryers. We would not be able to offer our customers safe and efficient machines without this vital data! Heed the warning...ground your UUT and use a grounding strap any wine you work with the TC’s or UUT. The A/D inputs are easily damaged!...not a criticism... just a fact!
Date published: 2019-04-14
Rated 5 out of 5 by from Awesome service awesome product Awesome product, easy to use. Basic setup need to use. Highly recommended.
Date published: 2022-08-11
  • y_2026, m_8, d_2, h_9
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_3
  • loc_en_US, sid_OM-USB-TC, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT

Windows 10 (and windows 11) HID drivers do not work anymore with the OMEGA OM-USB-TC. Please help.

Asked by: USB_TC_user
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM”
Answered by: Application Engineer PV
Date published: 2022-02-01

Dear Sr I want to know that is possible connect this module to an HMI with Modbus RS 485 and if is necessary some more interface module

Asked by: jorge67
sorry it cannot, it is strictly USB
Answered by: SAT_SAE
Date published: 2020-07-01

USB LEDs turn off after 10 seconds

Asked by: USB_TC_user
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM
Answered by: Application Engineer PV
Date published: 2022-03-11

What is the mounting feature for this module?

Asked by: kavya
Thank you for your question. Unfortunately, there is no mounting option available.
Answered by: Application Engineer PV
Date published: 2022-10-11

My unit is registering a 100degree temperature of a fluke temperature calibrator as 98.8 degrees I used the calibrate option in instacal after leaving the unit on for 30 minutes and the reading didn't change. Can I recalibrate this?

Asked by: XES_Claire
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM
Answered by: Application Engineer PV
Date published: 2022-03-18

Can multiple modules connect to the same PC and be used simultaneously?

Asked by: IDK_LOL
For TracerDAQ Pro as long as you are looking to monitor up to 48 channels, multiple modules can be connected to the same PC simultaneously.
Answered by: JA Engineer
Date published: 2023-01-24

Does Omega expose the software calls so that one could use their own software to communicate with the USB Data Acquisition Modules?

Asked by: Steve Y
Hello Steve I'm sorry we do not, though most of our data acquisition devices such as this unit can run on different software programs such as LabView as DasyLab
Answered by: JA Engineer
Date published: 2019-08-22
  • y_2026, m_8, d_2, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_7
  • loc_en_US, sid_OM-USB-TC, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 9ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration