Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

FTB1400-Series

316 SS Turbine Flow Meters w/ Pulse Output & NIST Cal Cert.

Models In Stock
  • Cost-Effective Solution for Turbine Flow Meter Applications
  • Rugged 316 Stainless Steel Construction Offers Long Service Life in Severe Operating Environments
  • Available with NPT or BSP Threads
  • Accurate and Repeatable Flow Measurement
FTB1400-Series
From $ 964.69
Models In Stock
316 SS Turbine Flow Meters w/ Pulse Output & NIST Cal Cert. FTB1400-Series FTB1400-Series
loading all models
Product Overview
  • Accuracy ± 0.5 %
  • Accuracy Detail ±1% of reading for 1" and larger, ±1% of reading over the upper 70% of the measuring range for 1 ⁄2" meters
  • Certifications NIST Traceable Calibration
  • Materials, Wetted 316 Stainless Steel, CD4MCu Stainless Steel, Tungsten Carbide
  • Media Compatibility Liquids
  • Operating Pressure, Max 5000 psi
  • Operating Temperature, Min -101 °C
  • Output Detail Magnetic Pickup: 30 mV/P-P
  • Output Signal DC Pulse
  • Process Connection Type NPT Male
  • Repeatability ±1%
  • Series ID FTB1400-Series
  • Turndown Ratio 10:1

Supported Applications

The Omega FTB-1400 Series consists of liquid turbine flow meters designed for rigorous measurement applications, originally developed for the secondary oil recovery market. These instruments measure fluid flow by rotating a turbine to generate AC voltage pulses via a magnetic pick-up proportional to volumetric flow. The series is suitable for corrosive and abrasive fluids.

Operating Conditions & Performance

The FTB-1400 Series operates within specific temperature, pressure, and accuracy envelopes defined by the model size and configuration:

  • Turbine Temperature Range: -101 to 177°C (-150 to 350°F); extended range of -101 to 232°C (-150 to 450°F) with the “HT” option.
  • Pressure Rating: Maximum 5000 psi.
  • Accuracy: ±1% of reading for 1" and larger meters; ±1% of reading over the upper 70% of the measuring range for ½" meters.
  • Repeatability: ±0.1%.
  • Turndown Ratio: 10:1.

The series is calibrated with water and includes a NIST traceable calibration certificate (5-point). Measurement ranges vary by bore size, spanning from 2.3 to 681 LPM (0.6 to 180 GPM) or 20 to 6000 Barrels/Day.

Configuration Options

The series offers configurable options for end connections, output signals, and temperature ratings across pipe sizes from ½ to 2 inches. Key construction materials include a 316 Stainless Steel body and rotor support, CD4MCU Stainless Steel rotor, and tungsten carbide rotor shaft and journal bearings.

End Connections

  • NPT (standard)
  • BSPP optional (add suffix “BSP” to model number for additional cost)

Output Signal Options

The standard output is an AC voltage pulse generated by a magnetic pick-up. Two specific signal configurations are available via model suffixes:

  • -AMP Suffix: Amplified pulse output (not available on “HT” models).
  • -HT Suffix: High temperature magnetic pulse output, extending the operating range to -101 to 232°C (-150 to 450°F) (not available on “AMP” models).

Cables and Accessories

A cable with a 2-pin connector is required for remote display operation but sold separately. Available accessories include:

  • FTB-1400-CABLE: 3 m (10') cable assembly with 2-pin connector.
  • FTB-1400-90CABLE: 3 m (10') cable assembly with 2-pin 90° connector.
  • FTB-1400-MP: Replacement standard magnetic pick-up.

Key Product Differences

The FTB-1400 Series is differentiated by bore size, end connection type, and output configuration. Model numbers follow the format FTB-XXXX - [End Connection] - [BORE]. For example, model FTB-1411 features a ½ NPT end connection with a 3/8" bore.

Variants are distinguished by their specific flow ranges and K-Factors. The series includes models such as the FTB-1425 (1 NPT, 1" bore) covering 18.9 to 189 LPM with a K-Factor of 870 Pul/Gal, and larger sizes like the FTB-1431 (1½ NPT, 1-1/2" bore) covering 56.8 to 681 LPM.

Selection between standard, amplified (-AMP), or high temperature (-HT) versions depends on process requirements and signal conditioning needs, noting that -AMP and -HT options are mutually exclusive per model number rules.

Accessories

accessories

REPAIR KT FTB-1412 & 1422
$442.46 / each
0 In Stock
REPAIR KT FTB-1413 & 1423
$436.70 / each
0 In Stock

cables

2 PIN 90DEGREE CONN W/10'CABLE
$145.58 / each
2 In Stock
10' CABLE W/3-PIN CONNECTOR
$148.32 / each
8 In Stock
2-PIN STR CONNECTOR 10' CABLE
$136.71 / each
21 In Stock
10' HI-TEMP W/2-PIN STR CNCTR
$330.78 / each
0 In Stock

consumables

REPAIR KT FTB-1411 & 1421
$451.02 / each
0 In Stock
REPAIR KT FTB-1424
$436.70 / each
0 In Stock
REPAIR KIT FOR FTB-1425
$333.64 / each
0 In Stock
REPAIR KT FTB-1431 & FTB-1441
$451.02 / each
0 In Stock

sensors

STD MAGNETIC PICK-UP FTB-1400
$92.58 / each
5 In Stock
Rated 5 out of 5 by from Beautifully engineered and manufactured I purchased the sensor and digital display for data acquisition in an industrial cooling system to facilitate design and implementation of a new and improved cooling system for composites molding.
Date published: 2017-08-01
  • y_2026, m_8, d_6, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_FTB-1411, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT

Could this be used with liquid nitrogen? (-196 C)

Asked by: coolMotors
Thank you for your inquiry! Unfortunately, the FTB-1400 series meters are only rated for down to -101C and would not be suited for -196C
Answered by: Application Engineer JM
Date published: 2022-05-04

Is it possible for this flow meter to operate with its exterior submerged? If so, up to what external pressure will it tolerate?

Asked by: mfeltis
Thank you for your inquiry. Unfortunately, it is not recommended to use this flow meter for submersible applications.
Answered by: Applications Engineer JJC
Date published: 2024-01-10

Could this be used for Gaseous Oxygen?

Asked by: Yetziell
Thank you for your inquiry about the turbine flow meter. This series of flow meters is only for liquids, not gases. The FMA1700/1800A or FMA-A2000 series mass flow meters would be a good suggestion to review.
Answered by: Application Engineer JC
Date published: 2022-11-03

How frequently do you recommend calibration of this FTB-1411 flow meter?

Asked by: Sarah123
Thank you for your inquiry. Omega recommends on an annual basis.
Answered by: Application Engineer JC
Date published: 2023-01-20

What would be the approximate response time of the flowmeter in miliseconds to reach e.g. 99% of the measured flow rate value?

Asked by: bv01
Thank you for your inquiry the turbine flow meter. It will have an instaneous response when it reaches the miniumum respectively in milliseconds.
Answered by: Application Engineer JC
Date published: 2022-06-16

Can you please confirm the connection process size for the FTB-1413 type flow meter? The Data Sheet (PDF) states 3/4" NPT but the Specs. tab above states 1/2" NPT.

Asked by: bv01
Thank you for your inquiry! The FTB-1413 has 1/2" male NPTS connections
Answered by: Application Engineer JM
Date published: 2022-06-17

Do you have any flow meters for water that have a suitable wireless r Ethernet interface that has an existing corresponding Windows APP to log instantaneous rate versus time and total floww accumulation?

Asked by: LAM1
Thank you for your inquiry about the turbine flow meter. Unfortunately, there is no 'Smart flow meter sensor' available, although, the Picomag is a magnetic flow meter that has Bluetooth features that may be a better alternative.
Answered by: Application Engineer JC
Date published: 2023-03-28

Would this be suitable for a low flow steam application? ROUGH flow range of about 6 to 82 kg/hr @ 75 psi, 160 Deg C.

Asked by: EI_C
Thank you for your inquiry. The turbine flow meter is ideal for water or liquids, not steam.
Answered by: Applications Engineer JJC
Date published: 2024-12-09
  • y_2026, m_8, d_5, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_11
  • loc_en_US, sid_FTB-1411, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 34ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration