Models In Stock
  • Available Stainless Steel Valve Body Resists Corrosion
  • NEMA-4 (IP65) Housing Standard
  • Mounts in Any Position
  • Rated for Continuous Duty
SV100-SV200-Series
From $ 198.13
Models In Stock
2-Way, NC, Brass & SS, General Purpose Solenoid Valves SV100-SV200-Series SV100-SV200-Series
loading all models
Product Overview
  • Coil Power 10 W
  • Duty Cycle 100%
  • Enclosure Ratings IP65, NEMA Type 4
  • Media Compatibility Clean dry air / inert gas, Clean process / cooling water, Compatible Liquids, Inert / non-reactive gases, Oils / lubricants, Organic solvents, Water
  • Media Type N/A
  • Mounting Pipe mounting, any direction
  • Operating Temperature, Max 50 °C
  • Operating Temperature, Min -9 °C
  • Process Connection Type NPT Male
  • Series ID SV100-SV200-Series
  • Supply Voltage 120 Vac
  • Valve Position Normally Closed
  • Weight 500 g

Supported Applications

The Omega SV100 and SV200 Series solenoid valves are designed for industrial and laboratory applications involving liquids and gases. The series includes general-purpose 2, 3, and 4-way configurations made of brass or stainless steel, as well as specialty valves for hot water and steam applications.

Documented application areas include:

  • Automation
  • Humidifiers
  • Water treatment
  • Dispensing systems
  • Laundry and dry cleaning equipment
  • Machine tools
  • Vending machines

Operating Conditions & Performance

The SV100-SV200 Series supports a broad range of media, including air or nontoxic nonflammable gases (Code A), acetylene (Code AC), common refrigerants except ammonia (Code F), city gas (Code G), gasoline (Code GA), petroleum-based hydraulic oils with viscosities from 125 to 400 SSU at 38°C (Code HO), liquid propane gas (Code LP), fuel oils Nos. 1 and 2 or up to No. 6 depending on viscosity, oxygen (Code OX), steam (Code S), and water or other aqueous nonflammable liquids (Code W).

Performance specifications vary by model family:

  • Ambient Temperature: -9 to 50°C (15 to 122°F) for the SV120 Series; specific ranges include 15 to 150°F for 10 watt coils, 15 to 77°F for 22 watt coils, and 15 to 122°F for steam valves SV231-235.
  • Response Time: 4 to 15 ms (SV121-SV127) and 30 to 60 ms (SV128).
  • Pressure Ratings: Maximum static pressure is rated at 1.5 times the maximum psid with vacuum capability greater than 5 microns ABS for SV121-SV128 models.

No minimum pressure is required except for specific pilot-operated or direct-acting valves: Models 128, 203-207, 211-217, 283-287, and 291-295 require 5 PSID; SV271 requires 15 PSID; SV281-SV282 require 3 PSID; and SV261 requires 2 PSID.

Configuration Options

The series offers extensive configuration options across valve type, actuation method, materials, and port sizes. Available variants include:

  • Valve Types & Actuation: Direct acting (SV121-127), pilot operated (SV106, SV128, SV203-207, SV222-225, SV232-235), direct lift (SV201, 202), and directional control configurations including 3-way normally closed (SV241-SV261) and 4-way pilot operated (SV271).
  • Port Sizes: Available from 1/8" NPT to 2" NPT, with CV values up to 38.
  • Housing & Materials: Stainless steel valve bodies are standard for the SV120 Series. Wetted materials include stainless steel, copper, and seals; additional materials such as polysulfone (SV128), FKM (SV201-SV202, SV281-SV282), ruby (SV211-SV212), Delrin (SV241-SV251), aluminum (SV271), and ethylene propylene rubber for hot water/steam valves are available depending on the model.
  • Enclosure Rating: NEMA 4 (IP65) housing is specified for rugged environments.
  • Power Supply: Standard coils operate at 10 W, 120 Vac, 50 to 60 Hz. Replacement coils are available in 110 Vac, 220 Vac, and 24 Vdc configurations (note: UL approval is not available with 24 Vdc coils).

Special service options include anti-water hammer valves (SV283-SV295) featuring adjustable closing times via a 4-position selector. SV128 must be mounted in an upright position, while other valves are designed to operate in any orientation.

Key Product Differences

The series distinguishes between direct-acting and pilot-operated mechanisms based on flow requirements and pressure differentials:

  • SV120 Series (Stainless Steel): Includes SV121-SV127 as direct-acting normally closed valves with orifice sizes ranging from ³⁄₆₄" to ¹⁄₄", and SV128 as a pilot-operated valve. These models feature KEL-F, FKM, or PTFE seals depending on the specific model number.
  • SV200 Series (Brass & Stainless Steel): Encompasses direct lift (SV201-SV202), pilot operated (SV203-207, SV222-225, etc.), and directional control valves. Specific models like SV261 function as quick exhaust valves with sleeve pilot exhaust ports that cannot be blocked.
  • Anti-Water Hammer Models: Valves SV283-SV295 allow adjustment of closing time from fast (Position 1) to slowest (Position 4). SV281 and SV282 are anti-water hammer valves without this adjustable feature.

Filtration recommendations vary by model: 100 microns or better is recommended for models 128, 203-207, and 211-217; 5 to 25 microns or better is recommended for SV241-SV261 and SV271. Hot water and steam valves contain ethylene propylene rubber parts and must not be exposed to petroleum-based lubricants.

Rated 5 out of 5 by from If you need this, just buy it! Works great, no problems. Installed and functioning properly.
Date published: 2022-03-10
  • y_2026, m_8, d_13, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_SV121, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT

Is this valve suitable for helium

Asked by: Reese
Thank you for your inquiry. The valve can be used with gases.
Answered by: Applications Engineer JJC
Date published: 2024-03-28

What is the response time of this solenoid?

Asked by: Faheem
The model numbers SV121 through SV127 have a response time of 4 to 15 milliseconds. The model number SV128 has a response time of 30 to 60 milliseconds.
Answered by: Applicatrions Engineer JK
Date published: 2020-07-11

What kind of a filter is required for this solenoid? E.g. 40 micron? 15 micron? etc...

Asked by: Faheem
Sorry, We do not have this particular information available. Please contact us at pressure@omega for assistance
Answered by: Applicatrions Engineer JK
Date published: 2020-07-13

Is the AC/DC coil included with the solenoid valve (the 120V AC coil described) or does it need to be purchased separately? If it is to be purchased separately, what is the model number of the 120V AC coil mentioned in the description?

Asked by: Arpad
Thank you for your inquiry. The AC coil is included with the valve. The DC coils are sold separately.
Answered by: Applicatrions Engineer JK
Date published: 2020-11-16
  • y_2026, m_8, d_12, h_7CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_4
  • loc_en_US, sid_SV121, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 36ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration