CNI8D-Series
1/8 DIN Horizontal and Vertical Dual Display PID Controllers
- Embedded Ethernet Connectivity (Optional)
- Dual Display with Bright Color-Changing Feature
- Programmable Digital Filter
- 2 Control or Alarm Outputs (Choice of DC Pulse, Solid State Relays, Mechanical Relays, Analog Voltage and Current)
CNI8D-Series
From
$
617.54
Product Overview
- A/D Conversion Dual Slope
- Accuracy ± 0.5 °C (± 0.9 °F)
- Accuracy Detail ± 0.5°C temp; 0.03% rdg
- Additional Features 1 Dual Display Horizontal, Built-In Excitation, Front Removable
- Approvals UL, C-UL, CE per 2014/35/EU
- CMRR 120 dB
- Control Characteristics Action: Reverse (heat) or direct (cool) Modes: Time and amplitude proportional control; selectable manual or auto PID, proportional, proportional with integral, proportional with derivative and anti-reset Windup, and on/off Rate: 0 to 399.9 s Reset: 0 to 3999 s Cycle Time: 1 to 199 s; set to 0 for on/off Gain: 0.5 to 100% of span; setpoints 1 or 2 Damping: 0000 to 0008 Soak: 00.00 to 99.59 (HH:MM), or OFF Ramp to Setpoint: 00.00 to 99.59 (HH:MM), or OFF Auto Tune: Operator initiated from front pane
- Control Output SPDT Relay, Alarm
- Cutout Dimensions 45 x 92 mm
- Decimal Selection 0,001, 0,01, 0,1, None
- Digital Filter Programmable
- Display Size 46 mm (1.8 in)
- Display Type 4 Digit LED
- Display Type Note 4-digit 9-segment LED 10.2 mm (0.40"); i32, i16, i16D, i8DV 21 mm (0.83"); i8 10.2 mm (0.40") and 21 mm (0.83"); i8DH RED, GREEN, and AMBER programmable colors for process variable, setpoint and temperature units
- Enclosure Ratings NEMA Type 1
- Height 48 mm
- Impedance Input 10 MΩ for 100 mV; 1 MΩ for 1V or 10 Vdc
- Input Configuration Single-ended
- Input Type Thermocouple, RTD, mA, Voltage
- Input Voltage 0 to 100 mV, 0 to 1 Vdc, 0 to 10 Vdc
- Isolation Power to Input/Output: 2300 Vac per 1 minute test For Low Voltage Power Option: 1500 Vac per 1 minute test Power to Relay/SSR Output: 2300 Vac per 1 minute test Relay/SSR to Relay/SSR Output: 2300 Vac per 1 minute test RS232/485 to Input/Output: 500 Vac per 1 minute test
- Length 127 mm
- Current, Max 0 to 20 mA (5 Ω load)
- NMRR 60 dB
- Number of Inputs 4
- Offset Adjustment -1999 to 9999
- Operating Temperature, Max 50 °C
- Operating Temperature, Min 0 °C
- Output Detail Relay/Relay;Relay: 250 Vac or 30 Vdc @ 3 A (resistive load); configurable for on/off, PID and ramp and soak Output 1: SPDT, can be configured as alarm 1 output Output 2: SPDT, can be configured as alarm 2 output Isolated Analog Voltage and Current Current: 10 V max @ 20 mA output Voltage: 20 mA max for 0 to 10 V output
- Output Signal Current, Voltage
- Polarity Unipolar
- Resolution 1°/0.1°; 10 µV process
- RTD Type 100/500/1000Ω Pt sensor; 2-, 3- or 4-wire; α=0.00385 or 0.00392
- Sampling Rate 3 Hz (3 updates/second)
- Series ID CNI8D-Series
- Set Point Adjustment Menu Configurable
- Span Adjustment 0.001 to 9999 counts
- Step Response 0.7 sec for 99.9%
- Supply Power Note 90 to 240 Vac ± 10%, 50 to 400 Hz*, 110 to 300 Vdc, equivalent voltage Low Voltage Power Option: 24 Vac**, 12 to 36 Vdc for DPi/CNi/DPiS/CNiS; 20 to 36 Vdc for dual display, ethernet and isolated analog output from qualified safety approved source
- Supply Power Type AC
- Supply Voltage 90 to 240 Vac
- Temperature Stability RTD: 0.04°C/°C ;TC @ 25°C (77°F): 0.05°C/°C; Cold Junction Compensation; Process: 50 ppm/°C
- Thermocouple Lead Resistance, Max 100 Ω
- Thermocouple Type J, K, T, E, N, R, S, B, C, L
- Weight 295 g
- Width 96 mm
Supported Applications
The Omega CNI8D Series comprises 1/8 DIN horizontal and vertical dual display PID controllers designed for temperature, process, and strain control applications. These single-loop autotune controllers are engineered for industrial automation environments requiring precise regulation of thermocouple (TC), resistance temperature detector (RTD), analog voltage/current inputs, or strain measurements.
Documented application contexts include:
- Temperature Control: Monitoring and regulating processes using TC (ITS90) types J, K, T, E, R, S, B, C, N, L and RTD (ITS88) sensors.
- Process Variable Regulation: Managing analog voltage signals ranging from 0 to 100 mV, 0 to 1 V, or 0 to 10 Vdc, as well as current loops of 0 to 20 mA (4 to 20 mA).
- Strain Measurement: Specific models support strain inputs with resolutions down to 1 μV.
Operating Conditions & Performance
The CNI8D Series operates within an ambient temperature range of 0 to 55°C (32 to 131°F) and supports storage temperatures from 0 to 50°C (32 to 122°F). Humidity tolerance is rated at 90% RH non-condensing. The controllers feature a response time of 0.7 sec for 99.9% settling.
Performance specifications vary by input type:
- Accuracy (Temperature): ±0.5°C temp; ±0.03% rdg typical.
- Resolution: 1°/0.1° for temperature inputs and 10 μV process resolution (with specific strain models offering 10/1 μV).
- Stability: Temperature stability is documented as 0.04°C/°C RTD, 0.5°C/°C TC @ 25°C (77°F), and 50 ppm/°C for process inputs.
The series includes a programmable digital filter to manage signal noise in demanding environments.
Power Supply Options
- Standard Line Voltage: 90 to 240 Vac ±10%, 50 to 400 Hz, or 110-375 Vdc (power consumption: 4W for single display; 5W for dual display).
- Low Voltage Option: 20 to 36 Vdc or 24 Vac available via the "-DC" suffix.
Configuration Options
The CNI8D Series offers extensive configurability across housing orientation, output types, communication protocols, and display features. The controllers are designed for panel mounting with a front-removable design to facilitate maintenance without disconnecting rear wiring.
Housing & Dimensions
- Horizontal (CNi8DH): 48 H x 96 W x 127 mm D (1.89 x 3.78 x 5").
- Vertical (CNi8DV): 48 H x 48 W x 127 mm D (1.89 x 1.89 x 5").
- Strain Models: Specific dimensions of 25.4 H x 48 W x 127 mm D (1.0 x 1.89 x 5") are available for strain applications.
- Enclosure Ratings: NEMA 4X/Type 4 (IP65) front bezel or NEMA 1/Type 1 front bezel options depending on configuration.
Outputs & Alarms
The series supports two independent control or alarm outputs. Available output types include:- Mechanical Relay: Form "C" SPDT relays rated at 250 Vac @ 3 A Resistive Load.
- Solid State Relays (SSR): DC pulse or 0.5 A SSR options.
- Analog Output: Configurable for 0 to 10 Vdc or 0 to 20 mA current output.
- Pulse Output: Pulsed 10 Vdc output available.
Communication & Connectivity
The controllers support embedded Ethernet connectivity (optional) with an embedded Web server. Additional communication options include:- Isolated RS232 and RS485/422 (300 to 19.2 Kb).
- Ethernet combined with isolated RS485/422 hub for up to 31 devices.
Display Features
The dual display utilizes a programmable color-changing feature (green, amber, red) and includes a digital filter. The unit features plug/removable connectors with sturdy panel mounting sleeves and adjustable thumb nuts.Key Product Differences
The CNI8D Series is differentiated by specific model suffixes that define functional capabilities:
- -AL (Limit Alarm): Provides alarms only without PID control. Note: Analog output is not available with "-AL" units.
- -SM (Simplified Menu): Offers on/off control or alarms, excluding full PID functionality. This option is not available on CNiS strain models.
- -EIT: Adds Ethernet connectivity with an embedded Web server.
- -C24: Provides isolated RS232 and RS485/422 communication (not compatible with excitation).
- -C4EIT: Combines Ethernet with an embedded Web server plus an isolated RS485/422 hub.
- -DC: Enables 20 to 36 Vdc or 24 Vac power supply (not compatible with excitation).
The series also supports factory setup and configuration (-FS) options. Excitation voltages of 5 V, 10 V, or 24 V are available for specific sensor types, subject to compatibility constraints noted in the ordering guide.
PDFs & Manuals
Show Ratings & Reviews
Can you tell me what terminals/jumpers to use if I have a 2 or 3 wire RTD on a CNI8DH33? The online manual doesn't describe this but does show the 4 lead connection.
Thank you for your inquiry. For wiring questions please e-mail us at temp@omega.com.
Date published: 2021-09-30