Need assistance? Call us: 1-800-663-4209
CN8200-Series
1/16 DIN Universal Input Autotune Controller with Ramp & Soak
Models In Stock
- Field-Configurable Universal Inputs
- Autotuning, Direct or Reverse-Acting for Both Outputs
- User-Selectable Ramp to Setpoint
- 8 Ramp and 8 Soak Segments
CN8200-Series
From
$
512.81
Models In Stock
Product Overview
- Accuracy ± 0.2 %
- Accuracy Detail ± 0.2% FS, ± 1 digit
- CMRR 100 dB
- Cold Junction Compensation 0.05°C/°C ambient
- Contacts Twin bifurcated
- Control Characteristics Set point Limits: Limited to configured range for thermocouple and RTD; limited to scaled range; Alarms: Adjustable for high/low; selectable process or deviation; Rate (Derivative): 0 to 2400 seconds; Reset (Integral): 0 to 9600 seconds; Cycle Time: 0.2 to 120 seconds; Proportional Band: 1 to span of sensor; Dead band: Negative span to positive span of sensor; Hysteresis: 1 to span of sensor; Autotune Damping: Adjustable (low, normal, or high); Ramp to Set point: 1 to 9999 minutes; Autotune: Operator-initiated from front panel; Manual Control: Operator-initiated from front panel
- Cutout Dimensions 45 x 45 mm
- Depth Behind Panel 100 mm
- Display Size 9.2 mm (.36 in)
- Display Type 4 Digit LED
- Display Type Note Dual LED—4-digit, orange: process display; green: menu/parameter display; 9.2 mm (0.36")
- Electrical Connection Screw Terminal
- Enclosure Ratings IP65, NEMA Type 4X
- Events/Alarms 1 to 8
- Form factor 1/16 DIN
- Hardware and Software Requirements, Min CN8-SW (Optional Software): Minimum Hardware and Software Requirements: IBM PC or 100% compatible, Windows 95/98/NT; RS485 interface or RS232 to RS485 converter; Software Compatibility: CN8200 Series controllers; Software Capability: Supports up to 254 CN8200 Series controllers
- Height 53.3 mm
- Input Type Thermocouple, RTD, mA, Voltage
- Input Type Note Input Type: See input table on next page Digital Input: For remote setpoint, remote standby or ramp/soak run and hold Thermocouple Lead Resistance: 100 Ω maximum for rated accuracy Decimal Position: Selectable
- Length 8.21 mm
- Loops 0 to 99
- Measurement Type Current, Temperature, Voltage
- Measuring Range Type J (Iron-Constantan): -200 to 760°C, Type K (CHROMEGA®-ALOMEGA®): -270 to 1354°C, Type T (Copper-Constantan): -270 to 400°C, Type N (OMEGALLOY®) : -268 to 1300°C, Type R (Pt/13%Rh-Pt) : -50 to 1768°C, Type S (Pt/10%Rh-Pt) : -50 to 1768°C, Type B (Pt/30%Rh-Pt/6%Rh) : 0 to 1820°C, Type C (W/5%Re-W/26%Re) : 0 to 2315°C, Type E (CHROMEGA®-Constantan) : -150 to 1000°C, NNM 18% molybdenum vs nickel -06% cobalt : 0 to 1410°, Platinel II : -100 to 1232°C, RTD ((3-wire) 100 Ω Pt) : -200 to 850°C, RTD ((3-wire) 100 Ω Pt) : -199.9 to 375.0°C, 0 to 1V : Scalable (-1999 to 9999) selectable 1 to 5V : Scalable (-1999 to 9999) selectable 0 to 5V : Scalable (-1999 to 9999) selectable 0 to 10V : Scalable (-1999 to 9999) selectable 10 to 50 mV : Scalable (-1999 to 9999) selectable 0 to 50 mV : Scalable (-1999 to 9999) selectable 0 to 10 mV : Scalable (-1999 to 9999) selectable 0 to 100 mV : Scalable (-1999 to 9999) selectable 4 to 20 mA : Scalable (-1999 to 9999) selectable 0 to 20 mA : Scalable (-1999 to 9999) selectable
- Memory Backup Solid State
- Number of Inputs 1
- Operating Temperature, Max 55 °C
- Operating Temperature, Min 0 °C
- Ramp and Soak 8 Ramp & Soak
- Ramp Setpoint 1 to 9999 minutes
- Ramp/Soak Time 0 to 9999 minutes
- Relative Humidity 90% RH, non-condensing
- Repeatability ± 1 count
- Sampling Rate 10 Hz (10 updates/second)
- Series ID CN8200-Series
- Series Mode Rejection >70 dB
- Setpoint Resolution 1 count/0.1 count
- Supply Power Note 100 to 250V, 50/60 Hz (single-phase); 120 to 250 Vdc, 24 Vac/24 Vdc (optional)
- Temperature Stability 5 μV/°C Max
- Weight 226 g
- Width 53.3 mm
Supported Applications
The Omega CN8200 Series comprises 1/16 DIN universal temperature and process controllers designed for applications requiring precise autotuning, ramp-to-setpoint control, and multi-segment programming. The series supports field-configurable universal inputs including thermocouples (J, K, T, N, R, S, B, C, E), RTDs (3-wire 100 Ω Pt), Platinel II, voltage, current, and millivolt signals.
Key functional capabilities include:
- Ramp/Soak Control: Configurable for up to 8 ramp segments followed by 8 soak segments.
- Dual Display: Simultaneous Process Value (PV) and Setpoint (SV) indication with individual status LEDs.
- Remote Monitoring: Compatible with CN8-SW software for remote monitoring and control via RS232/485 communications options.
Operating Conditions & Performance
The controller operates within an ambient temperature range of 0 to 55°C (32 to 131°F) at a maximum humidity of 90% RH, non-condensing. The front panel features a NEMA 4X (IP65) enclosure rating.
Performance specifications include:
- Accuracy: ±0.2% FS, ±1 digit for rated accuracy conditions.
- Response Time: 10 Hz (100 ms).
- Hysteresis: Adjustable from 1 to span of sensor.
- Resolution: 1 count or 0.1 count depending on range selection.
The series supports a wide array of measurement ranges, including -270 to 1354°C (-454 to 2469°F) for specific thermocouple types and scalable electrical inputs from -1999 to 9999. Load resistance is limited to 100 Ω maximum for rated accuracy on analog outputs.
Configuration Options
Power Supply Options
The standard power supply supports a universal range of 100 to 250 Vac and 120 to 250 Vdc. An optional low-voltage configuration (-LV suffix) is available for 24 Vac/24 Vdc operation.
Input Types
The universal input capability covers the following sensor types:
- Thermocouples: J, K, T, N, R, S, B, C, E (including CHROMEGA®-ALOMEGA®, OMEGALLOY®, and W/5%Re-W/26%Re).
- RTDs: 3-wire 100 Ω Pt.
- Analog Signals: Voltage (0 to 1V, 1 to 5V, 0 to 5V, 0 to 10V), Current (4 to 20 mA, 0 to 20 mA), and Millivolt ranges.
Output Configurations
The series is available in single-output (CN8201) or dual-output (CN8202) models. Output types include:
- Mechanical Relay: 5 A @ 120 Vac, 3 A @ 240 Vac.
- Solid State Relay (SSR): 1 A continuous, 10 A surge @ 25°C.
- DC Pulse: 20 Vdc pulse output.
- Analog Current/Voltage: 4 to 20 mA (up to 800 Ω or 1000 Ω maximum depending on suffix), 0 to 5V, 0 to 10V, and various mV ranges.
Additional Options
The series supports a single additional option per controller. Available options include:
- Alarms: Single-alarm mechanical relay (-AL1), dual alarms with AC SSR (-AL2), or dual DC level alarms at 24 Vdc (-AL3).
- Communications: RS232 (-C2) or RS485 (-C4). The -C4 option can be configured for MODBUS® protocol and includes variants with digital inputs (switch closed, switch open, or 0/5V logic).
- Remote Setpoint: Switch-based or voltage-based remote setpoints.
- Transducer Excitation: Available at 15 Vdc (-XP1), 12 Vdc (-XP2), 10 Vdc (-XP3), or 5 Vdc (-XP4).
Key Product Differences
The CN8200 Series is differentiated by model number and output configuration:
- CN8201-(-*): Single-output ramp/soak controller.
- CN8202-(-*)-(-*): Dual-output ramp/soak controller, allowing independent selection of first and second output types (e.g., Relay + SSR).
The ordering suffix structure defines the specific configuration: <MODEL> - <FIRST OUTPUT SUFFIX> - <SECOND OUTPUT SUFFIX> - <LOW VOLTAGE SUFFIX> - <ADDITIONAL OPTION SUFFIX>. For example, a dual-output model with DC pulse and relay outputs configured for low voltage and an alarm would follow the pattern CN8202-DC1-R2-LV-AL3.
The series includes UL US and C UL US approvals. A 2-year warranty is standard, with OMEGACARE™ extended warranty programs available.
PDFs & Manuals
Software & Drivers
Show Ratings & Reviews
Rated 5 out of
5
by
PTElectrical from
A+
Great experience. Quick shipping. Item as described.
Date published: 2023-03-12
Rated 5 out of
5
by
Bobby100 from
Great Product
Great Product! Thanks for your quality work Omega!
Date published: 2022-01-31
Rated 4 out of
5
by
mybeer2018 from
Confusion
You should have shipped all 5 units together instead of splitting the order. No explanation provided. That just caused unnecessary confusion.
Date published: 2021-04-19
How do you access the jumpers for current input on a CN8200
Hi KarenCT,
Thank you for the inquiry. Manual pg 19 illustrates jumper positions.
https://assets.omega.com/manuals/M2942.pdf
To access the jumpers the outer shell will need to be removed. Clear the terminal blocks, press in at detents, and slide the shell towards the back.
Best regards,
OMEGA
Date published: 2023-02-06
Do you have software that supports Windows 7/10?
Microsoft offers the "Windows XP Mode" emulator you can download and install from Microsoft.com. This will allow you to install and run the product software. There is no software update available for this product.
Date published: 2019-09-25
Do you have software for CN8201 compatible with MAC OS?
Thank you for your inquiry Olaf. Unfortunately, all the software available for the CN8201 is only compatible with Windows operating systems.
Date published: 2024-06-06
Do you have software for CN8201 compatible with 64bit Windows OS?
Hi Olaf,
Thank you for the inquiry. This is a legacy controller. We do not have software revised for Windows 10.
Best regards
OMEGA
Date published: 2022-08-26
After downloading this software onto Windows XP, it requires a User ID and password to log onto Multi-Comm. What User ID and password should we use?
Thank you for your inquiry. Please email your request to temp@omega.com and we will review and advise.
Date published: 2020-12-11
If you do not support the current Windows OS, can you help with Matlab or Labview codes that connect to the controller based on RS232 communication?
Hi Olaf,
Thank you for the inquiry. Manuals for the CN8200 series include the serial command set. This may be useful to you. We do not offer example code for 3rd party software though.
Best regards
OMEGA