Italia 800 906 907 | Internazionale +39 022 333 1521 | Benvenuti sul nostro nuovo sito web. Avete riscontrato un problema o un bug? Segnalatelo qui.
FP1400-Series
Misuratore di portata a ruota a pale in plastica con allarmi e totalizzatori
Indicating Plastic Paddlewheel Flow Meter W/Alarms & Totalizers- Modelli in polipropilene o PVDF
- 29 unità di misura ingegneristiche (incluso definito dall’utente)
- Due totalizzatori programmabili
- Allarmi programmabili
FP1400-Series
Da
£
807.79
Panoramica del Prodotto
- Accuracy ± 1 %
- Alarm Types 2
- Approvals CE
- Approvals Note EMC Compliance with 89/336/EEC as amended. Emission Standard: EN 55011:1991, Group 1, Class A Immunity Standard: EN 55082-1:1992
- Data Interface RS232
- Nota sull'uscita digitale UCE 40 Vdc, ICE 150 mA
- Tipologia Display LCD
- Tipologia Display Nota Optional local 2 x 16 characters LCD with adjustable backlight (2 lines of text),Optional 4 pushbutton key pad
- Potenza elettrica 4 to 20 mA, 0 to 5 Vdc
- Pressione operativa, max 150 psi
- Pressione operativa, min 0 psi
- Temperatura di esercizio, max 60 °C
- Temperatura di esercizio minima -10 °C
- Dettagli sull'uscita Linear 0 to 5 Vdc (3000 Ω minimum load impedance); linear 4 to 20 mA (500 Ω maximum loop resistance). Maximum noise 20 mV peak to peak (for 0 to 5 Vdc output); Flow Pulse Output: 3.3 Vdc
- Nota sulla caduta di pressione Maximum Pressure Drop: @ 15 psi for sized units @ 20 psi all other sizes
- Tipo di pressione Gauge
- Tipo di attacco al processo NPT Female
- Temperatura di processo, max 60 °C
- Temperatura di processo, min. 0 °C
- Errore di ripetibilit ±0.25%
- Tempo di risposta 1 s
- Nota sul tempo di risposta Approx 1 sec (above 10% of full scale flow), approx 2 seconds (below 10% of full scale flow)
- ID serie FP1400-Series
- Fornitura Nota 11 to 26 Vdc, 100 mV maximum peak to peak output noise, Consumption: +12 Vdc (150 mA maximum); +24 Vdc (100 mA maximum); circuit board have built-in polarity reversal protection, 300 mA resettable fuse provide power input protection.
- Accuratezza della temperatura ± 0.5 °C
- Nota sulla viscosità 1 cSt (water) can be used for liquids up to 50 cSt with field calibration (max flow range may be affected
FP1400 Series flow meters support various functions including; two independently programmable flow totalizers, user programmable low, high or range flow and temperature alarm, two sets of user programmable optically isolated outputs, self diagnostic alarm, and flow pulse output. The flow rate can be displayed in 29 different volumetric or mass flow engineering units. Flow meter parameters and functions can be programmed locally via optional key pad and LCD or remotely via the RS232/RS485 interface. Local 2 x 16 LCD readout with adjustable backlight provides flow rate, temperature, total volume reading in currently selected engineering units, diagnostic events indication and feature a password protected access to the process parameters to ensure against tampering or resetting. Liquid flowing through the unit causes the paddle-wheel to spin. As the magnets embedded in the paddle spin past the sensor, electrical pulses are produced in which frequency is proportional to the flow rate. The number of pulses per desired time interval and the K factor (number of pulses/gal) make it is possible to calculate the flow rate and volume passing through the unit. On board CPU and signal conditioner circuitry perform accurate flow and total computation, digital communication and analog 0 to 5 Vdc or 4 to 20 mA output signals. Non-volatile memory stores all hardware specific and user programmable variables, including flow linearization table.
PDF & Manuali