Netherlands 07077 03815 | Intl +31 (0) 7077 03815 | Welcome to our new website, found an issue or bug? Please report it here
OM-CP-HITEMP140-FP-Series
High Temperature Data Logger with Flexible Probe
- PFA Coated Flexible Probe Available in 91.4 cm (36') or 183 cm (72') Lengths
- Operating Temperature Range: -40 to 140ºC (-40 to 284°F)
- Optional Vented or Flush Thermal Shield for Operation up to 250°C (482°F)
- Probe Measures from -60 to 260°C (-76 to 500°F)
OM-CP-HITEMP140-FP-Series
From
€
698,30
Product Overview
- Battery life up to 1 yr
- Battery Size and Type 3.6V Li-ion
- Calibration Digital calibration through software
- Data Interface USB
- Data Interface Note OM-CP-IFC400 USB docking station or OM-CP-IFC406 multiplexer interface required; 125,000 baud
- Diameter 24.6 mm
- Enclosure Ratings IP68
- Form factor Handheld
- Height 75 mm
- Materials, Wetted Polyurethane, Stainless Steel
- Measurement Type Temperature
- Memory 32767
- Memory Note 32,767 readings
- Number of Measurements 1
- Operating Temperature, Max 140 °C
- Operating Temperature, Min -40 °C
- Probe Diameter 0.1 in
- Readings in Trigger Settings Mode 10,922 readings
- Real Time Recording May be used with PC to monitor and record data in real time
- Relative Humidity, Max 1
- Relative Humidity, Min 0%
- Samples,Max 32700
- Sampling Rate 4 Hz (4 updates/second)
- Sampling Rate Note 4 readings per second up to 1 reading every 24 hours
- Series ID OM-CP-HITEMP140-FP-Series
- Software Compatibility Windows XP SP3/Vista/7 and 8 (32- and 64-bit)
- Start Modes Adjustable Delay Start, Immediate Start
- Stop Modes Adjustable Delay Stop, Manual Through Software
- Supply Power Type Battery
- Temperature Accuracy ± 0.1 °C
- Temperature Resolution 0.01 °C
- Temperature Sensor Type RTD
- Temperature Sensor Type Note Flexible 100 Ω platinum RTD
- Time Accuracy ± 1 minute/month
- Weight 85 g
Supported Applications
The Omega OM-CP-HITEMP140-FP Series is a high-temperature data logger featuring a long, flexible RTD probe with a narrow diameter. The series is designed for mapping, validation, and monitoring of high-temperature surfaces and environments. Documented applications include steam sterilization and lyophilization processes.
Operating Conditions & Performance
The data logger records up to 32,767 time-stamped readings using non-volatile solid-state memory with a resolution of 0.01°C (0.02°F). The probe measurement range is -60 to 260°C (-76 to 500°F), while the operating temperature range for the device body is -40 to 140°C (-40 to 284°F).
When equipped with an optional thermal shield, the operating environment extends from -200 to 250°C (-328 to 482°F). This extended range is time-limited; exposure duration depends on ambient temperature and whether the sensor is in air or liquid. For example, at 150°C (302°F), maximum exposure times are listed as 59 minutes for vented shields in air versus 66 minutes for flush top shields in air.
Response time specifications vary by medium:
- In Air: t60 is 30 seconds; t90 is 70 seconds.
- In Water: t60 is 3.5 seconds; t90 is 6.5 seconds.
The device maintains an accuracy of ±0.1°C (±0.18°F) and features a PFA coated flexible probe with wetted materials consisting of PFA insulated cable. The enclosure rating is IP68, and the housing material for the thermal shield options includes 316 SS components.
Configuration Options
The series supports configuration across multiple dimensions including probe length, thermal shielding type, and certification levels. Model numbers follow the format OM-CP-HITEMP140-FP - <PROBE LENGTH> - <THERMAL SHIELD> - <CERTIFICATION>. Available configurations include:
- Probe Lengths: 91.4 cm (36") or 183 cm (72").
- Thermal Shields: Vented thermal shield (OM-CP-HITEMP140-FP-TSK) and flush top thermal shield (OM-CP-HITEMP140-FP-TSK-FL). The vented enclosure measures 109 x 51 mm dia. (4.3 x 2.0") with a weight of 270 g (9.5 oz), while the flush top enclosure is 70 x 51 mm dia. (2.75 x 2.0") weighing 190 g (6.7 oz).
- Certifications: Optional NIST calibration certificate and optional 5 YEAR WARRANTY.
Data retrieval requires the OM-CP-IFC400 USB docking station or the OM-CP-IFC406 multiplexer interface. The device is powered by a user-replaceable 3.6V high-temperature lithium battery (OM-CP-BAT110). Additional accessories include the OM-CP-MULTIMOUNT-Z mount/stand and the OM-CP-SVP-SYSTEM software validation package.
Key Product Differences
Variants within the series are distinguished by probe length, thermal shield configuration, and inclusion of certification documents. The base models (e.g., OM-CP-HITEMP140-FP-36) feature a flexible probe without an external thermal shield enclosure. Models with "TSK" in the part number include a vented PTFE enclosure to extend operating limits up to 250°C (482°F). The "FL" suffix denotes a flush top thermal shield configuration, which offers different exposure time tolerances compared to the vented version at elevated temperatures. Suffixes ending in "-CERT" indicate inclusion of an optional NIST calibration certificate.
Software & Drivers
Accessories
accessories
Secure Software for Use with OM-CP Series Data Loggers
€ 2.526,92 / each