Skip to search Skip to main content Skip to navigation

United Kingdom 0800 488 488 | Intl +44 (0) 161 777 6611 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

MDS8PT

PLATINUM™ Series Universal Benchtop Digital Panel Meter

  • UL and cUL Certified
  • Universal Inputs
  • Easy-to-Use and Configure
  • High Quality & Accuracy
MDS8PT
From £ 730.99
PLATINUM™ Series Universal Benchtop Digital Panel Meter MDS8PT MDS8PT
loading all models
Product Overview
  • Decimal Selection Note None, 0.1 for temperature; none, 0.1, 0.01 or 0.001 for process
  • A/D Conversion 24-bit sigma delta
  • Accuracy 0.03 % FS
  • Additional Features 1 Programmable 3 Color Display
  • CMRR 120 dB
  • Configuration Differential
  • Control Output 2 SPDT Relay
  • Decimal Selection 0,001, 0,01, 0,1, None
  • Digital Filter Programmable
  • Display Size 21 mm (.82 in)
  • Display Type Note 4 or 6 digit, 9-segment LED, 21 mm (0.83") GREEN, AMBER, and RED programmable colors for process variable, set point and temperature units
  • Form factor Benchtop
  • Frequency 50/60 Hz
  • Input Current 4 to 20 mA, 0 to 24 mA
  • Input Type Thermocouple, RTD, Thermistor, Current, Voltage
  • Input Voltage -100 to 100 mV, -1 to 1 V, -10 to 10 Vdc
  • Measurement Type Temperature, Current, Voltage, Differential Voltage
  • Measuring Range Process Voltage: +100 mV, ±1, +10 Vdc;Process Current: Scalable within 0 to 24 mA;;Thermocouple:;Type J: -210 to 760°C;Type K: -270 to -160°C and -160 to 1372°C;Type T: -270 to -190°C and -190 to 400°C;Type E: -270 to -220°C and -220 to 1000°C;Type R: -50 to 40°C and 40 to 1768°C;Type S: -50 to 100°C and 100 to 1768°C;Type B: 100 to 640°C and 640 to 1820°C;Type C: 0 to 2320°C;Type N: -250 to -100°C and -100 to 1300°C;Type L: -200 to 900°C;;RTD:;Pt, 0.00385, 100, 500, 1000 Ω: -200 to 900°C;Pt, 0.00392, 100, 500, 1000 Ω: -200 to 850°C;;Thermistor:;2252 Ω: -40 to 120°C;5K Ω: -30 to 140°C;10K Ω: -20 to 150°C
  • Number of Inputs 1
  • Output Detail Optional Alarm 1 and 2 (Programmable) Type: Form “C” SPDT relays Operation: High/low, above/below, limited output to 30 Vrms, 60 Vdc max, band, latch/unlatch, normally open/ normally closed and process/deviation; front panel configurations Optional Analog Output (Programmable): Isolated, retransmission 0 to 10 Vdc or 0 to 20 mA, 500 Ω max (output 1 only). Accuracy is ± 1% of FS when following conditions are satisfied. 1) Input is not scaled below 1% of input FS 2) Analog output is not scaled below 3% of output FS
  • Polarity Bipolar
  • Resolution Temperature :1° /0.1° ; process : 10 µV
  • RTD Input Range 100/500/1000 Ω Pt sensor, 2-, 3- or 4-wire; 0.00385 or 0.00392 curve
  • Series ID MDS8PT
  • Set Point Adjustment Menu Configurable
  • Span Adjustment 0.001 to 9999 counts
  • Step Response 0.7 sec for 99.9%
  • Supply Power Type AC
  • Supply Voltage 90 to 240 Vac
  • Temperature Stability RTD: 0.04°C/°C ;TC@ 25°C (77°F): 0.05°C/°C ;Cold Junction Compensation Process: 50 ppm/°C
  • Thermal Effects -9999 to +9999
  • Thermistor Input Range 2252 Ω, 5K Ω, 10K Ω
  • Thermocouple Type J, K, T, E, N, R, S, B, C, L

Supported Applications

The MDS8PT PLATINUM™ Series is a universal-input benchtop digital panel meter built for laboratory and portable temperature or process measurement. A single universal input accepts thermocouple, RTD, thermistor, or voltage/current signals, and the meter is factory configured and calibrated for use straight out of the box. Housed in a benchtop plastic enclosure based on a 1/8 DIN (96 x 48 mm) panel meter, it brings PLATINUM Series capability to the bench.

The signature Pt Series color-changing LED display can be programmed to switch between GREEN, AMBER, and RED at any set-point or alarm point, giving an immediate visual cue of process status. With dual alarm relays, isolated analog output, and serial or Ethernet communications (including Modbus®), the meter suits process monitoring and control, test benches, calibration labs, and general temperature and process indication.

Each meter ships with a power cord and user's guide. For safety, do not exceed the voltage rating, always disconnect power before changing signal or power connections, and do not operate in flammable or explosive environments.

Operating Conditions & Performance

The universal input covers a broad set of sensor types and signal ranges:

  • Thermocouple: Types J, K, T, E, R, S, B, N, C, and U
  • RTD: Pt100, Pt1000, Ni120, Ni1000
  • Thermistor: 10kΩ, 20kΩ, 50kΩ, 100kΩ
  • Voltage: ranges including 0-10 VDC down to millivolt spans
  • Current: 4-20 mA, 0-20 mA, 0-10 mA

Measurement accuracy is ±0.05% of reading ±1 digit with a resolution of 0.1 °C or 0.1 °F and a 1 second response time. The meter runs on 100-240 VAC, 50/60 Hz, operates from 0 °C to 50 °C, and stores from -20 °C to 60 °C at 0% to 90% RH, non-condensing. The enclosure carries an IP50 rating.

An isolated analog output can be configured for 0-20 mA, 4-20 mA, or 0-10 VDC, driving up to 500 Ω max on output 1. The benchtop unit measures 192 mm (W) x 100 mm (H) x 120 mm (D), weighs 0.8 kg, and reads out on a 7-segment LED display. It is CE and UKCA marked and UL US listed.

Configuration Options

The four models differ in two ways: display digit count and the communication/output options fitted. The MDS8PT models use a 4-digit LED display, while the MDS8EPT models use a 6-digit display for finer numeric readout. Both share the same universal input and color-changing display.

The option suffixes build up the meter's connectivity, following the PLATINUM feature codes:

  • -330: Dual Alarm Relays
  • -C24: Isolated RS232 and RS485
  • -EIP: Ethernet
  • -A: Isolated Analog Output

A base -330 model provides dual alarm relays only, while a fully optioned -330-C24-EIP-A model adds isolated RS232/485 serial communication, embedded Ethernet, and an isolated analog output — turning the same benchtop meter into a fully networked instrument.

Key Product Differences

The series comprises four ordering configurations, pairing a 4-digit or 6-digit display with either the base relay package or the full communications-and-output package:

  • MDS8PT-330 — 1-channel 4-digit benchtop panel meter, universal input with dual alarm relays
  • MDS8EPT-330 — 1-channel 6-digit benchtop panel meter, universal inputs with dual alarm relays
  • MDS8PT-330-C24-EIP-A — 4-digit meter with dual alarm relays, RS232/485 communication, embedded Ethernet, and isolated analog output
  • MDS8EPT-330-C24-EIP-A — 6-digit meter with dual alarm relays, RS232/485 communication, embedded Ethernet, and isolated analog output

A power cord is required for operation and selected to suit the destination: POWER CORD-MOLDED (North America, 120 Vac), POWER CORD-DM (Denmark), POWER CORD-E-10A (Continental Europe), POWER CORD-IT (Italy or Ireland), POWER CORD-UK (United Kingdom), or POWER CORD-SE with stripped ends for all countries.

Accessories

accessories

PLATINUM™ Series Universal Benchtop Digital Panel Meter
£1,144.44 / each
0 In Stock
PLATINUM™ Series Universal Benchtop Digital Panel Meter
£1,115.88 / each
0 In Stock
en-GB
en_UK
Save Configuration