Product Overview
  • Accuracy ± 0.5 %
  • Accuracy Detail ± 0.5% or reading maximum error @ 25°C (77ºF)
  • Additional Features 1 Field Mount, Sensors
  • Altitude,Max 4000 m
  • Conductivity Measurement 0.0000 to 99999 μS
  • Control Characteristics Dry-Contact Relays: 2 Open Collector: 1 Type: SPDT N/A Form C: N/A Maximum Current Rating: 5 A resistive 50 mA DC Maximum Voltage Rating: 30 Vdc or 250 Vac Hysteresis Adjustable: Absolute in engineering units (EUs) Latch Reset: In test screen only Delay: 9999.9 seconds (maximum) Test Mode: Set on/off Cycle Time: 99999 seconds (maximum) Maximum Pulse Rate: 400 pulses/minute Proportional Pulse: 400 pulses/minute Volumetric Pulse Width: 0.1 to 3200 s Pulse Width Modulation: 0.1 to 320 s
  • Display Measuring Units kΩ, MΩ, ms, ppb, ppm, μS
  • Display Note LCD Contrast: 5 settings
  • Display Type Backlit LCD
  • Display Type Note Backlit, 7 and 14-segment LCD
  • Electrical Connection Screw Terminal
  • Electrical Output 4 to 20 mA
  • Enclosure Material PBT
  • Enclosure Ratings IP65, NEMA Type 4X
  • Form factor 1/4 DIN
  • Frequency 0.5 to 1500 Hz
  • Input Note Digital Serial: ACSII, TTL level, 9600 bps Frequency Input: Sensitivity: 80 mV @ 5 Hz, gradually increasing with frequency Span: 0.5 Hz to 1500 Hz @ TTL level input
  • Input Type Pulse, S3L
  • Input Type Note Digital or AC Frequency: pH/ORP input via the digital output from the PHTX-2750 pH/ORP sensor electronics Conductivity/Resistivity: Input directly from OMEGA conductivity/ resistivity electrodes via direct conductivity/resistivity module or via CDTX-2850
  • Keypad 4 buttons, injection-molded silicone rubber seal
  • LED Indicators “Dial-style” digital bar graph, LEDs for open collector, relays and warning indicator
  • Measurement Type Flow, pH, ORP, conductivity, salinity, pressure, temperature, batch
  • Mounting Specified to Omega field mount junction boxes
  • Number of Channels 1
  • ORP Measurement Range -1999 to 1999.9 mV
  • Output Detail 4 to 20 mA (10.8 to 35.2 Vdc, 30 mA maximum)
  • Over-Voltage Protection 48 V transient protection device current limiting for circuit protection and reverse-voltage protection
  • PH Measurement Range 0 to 15 pH
  • Relative Humidity 0 to 100% condensing for field mount; 0 to 95% non-condensing for panel mount
  • Repeatability ±0.2% of reading
  • Resolution 1 μS
  • Sensor Voltage 4.9 to 5.5 Vdc @ 25°C, regulated short circuit protected
  • Series ID DPU91-Series
  • Storage Temperature, Max 70 °C
  • Storage Temperature, Min -15 °C
  • Supply Power Note DPU91 without Relay Module: 200 mA @ 10.8 to 35.2 Vdc DPU91 with Relay Module: 300 mA @ 10.8 to 35.2 Vdc
  • Supply Voltage 10.8 to 35.2 Vdc
  • Update Rate 1 sec
  • Weight 0.63 kg
  • Wire Gauge 14 AWG

Supported Applications

The Omega DPU91 Series Multi-Parameter Input Transmitter is a single-channel interface designed for measuring process parameters including flow, pH/ORP, conductivity/resistivity, salinity, and temperature. The series supports batch control applications via the DPU91-BC variant with optional module support.

Documented measurement types include:

  • Flow
  • pH/ORP
  • Conductivity/Resistivity
  • Salinity
  • Temperature
  • Pressure
  • Batch

Operating Conditions & Performance

The DPU91 Series operates with a DC power supply of 10.8 to 35.2 Vdc, regulated. The unit features an auto-sensing backlit LCD display with a 'dial-style' digital bar graph.

Performance specifications include:

  • Accuracy: ±0.5% or reading maximum error @ 25°C (77°F); 0.5% of reading (display)
  • Repeatability: ±0.2% of reading
  • Resolution: 1 µS
  • Update Rate: 1 second
  • Hysteresis: Adjustable: Absolute in engineering units (EUs)

Ambient operating temperature for the backlit LCD is -10 to 70°C (14 to 158°F). Storage temperature ranges from -15 to 70°C (5 to 158°F).

Configuration Options

The series offers configurable mounting and output options. The DPU91 is available in field-mount configurations, while the DPU91P supports panel mount applications.

Housing & Mounting:

  • Enclosure Rating: ¼ DIN, NEMA 4X/IP65
  • Housing Material: PBT
  • Dimensions (H x W x D): 99.06 mm (3.90 in) x 99.06 mm (3.90 in) x 91.44 mm (3.60 in)
  • Weight: 0.63 kg (1.63 lb)

Outputs & Connectivity:

  • Digital serial ASCII, TTL level, 9600 bps
  • 4 to 20 mA (10.8 to 35.2 Vdc, 30 mA maximum)
  • Dry-Contact Relays: 2
  • Open Collector: 1
  • HART® Protocol: Available via DPU90-COMM module (superimposes digital signal onto 4 to 20 mA)

Sensor Compatibility & Accessories:

  • Flow Sensors: Compatible with FP-5100, FP-5200, FP-5300, FPB100, FMG3000 (field mount); Integral Mount FP-5600, FP-8500, FP-8500A; and FP-5061, FP-5070, FP-2540, FMG-550.
  • pH/ORP Sensors: Submersible Mounted PHE-2724, HE-2726, ORE-2725; In-Line Mounted PHE-2724, HE-2726, ORE-2725.
  • Conductivity/Resistivity/Salinity Sensors: CDCE-90 Series Sensors*.

The series supports optional modules including DPU90-R (programmable dual relay output), DPU90-COMM, and PC configuration tools. Mounting kits such as FP90UM (universal) and FP90IM (integral) are available for field mounted units.

Key Product Differences

The series distinguishes between panel mount and field mount configurations:

  • DPU91 / DPU91-BC: Field-mount display/transmitter. The -BC variant adds batch module support for batching control.
  • DPU91P: Panel mount display (¼ DIN). Note that panel mount displays cannot be mounted integrally to the sensor in configurations requiring integral mounting brackets.

Sensor installation fittings and specific modules are sold separately. The DPU90-AK angle adjustment kit is available for field mount and conductivity/resistivity/salinity input units.

Accessories

accessories

PC COMM CONFIGURATION TOOL
£273.48 / each
0 In Stock
This item is discontinued. Please contact Technical Sales Team for assistance.

installation hardware

FLOW INTEGRAL MOUNT
£75.52 / each
0 In Stock
This item is discontinued. Please contact Technical Sales Team for assistance.
LIQUID TIGHT CONNECTOR (3) KIT
£81.14 / each
0 In Stock
This item is discontinued. Please contact Technical Sales Team for assistance.

meters/controllers

signal conditioners

HART COMMUNICATIONS MODULE
£308.96 / each
1 In Stock
en-GB
en_UK
Save Configuration