Passer à la recherche Passer au contenu principal Passer à la navigation

Besoin d'aide? Appelez-nous: 1-800-663-4209

Nous avons remarqué que vous êtes dans , veuillez visiter votre site local en cliquant sur le lien ci-dessous pour des offres et un support régionaux.

LCM412-IS

Cellules de charge métriques, intrinsèquement sûres, à profil bas

Metric, Intrinsically Safe, Low Profile Load Cells
  • Norme de sécurité intrinsèque FM
  • Sortie 4 à 20 mA
  • Étalonnage traçable NIST en 5 points inclus
  • Interchangeabilité de 0,25 %
Metric, Intrinsically Safe, Low Profile Load Cells LCM412-IS LCM412-IS
loading all models
Aperçu du produit
  • 5-Point Calibration 0%, 50%, 100%, 50%, 0%
  • Additional Features 1 Potentiometers Standard
  • Approvals FM
  • Base Plate LCM412-TP350
  • Calibration Option 5 POINT NIST
  • Electrical Connection M12 4 pin Female
  • Electrical Output 4-12-20 mA
  • Electrical Output Note Two Directions Output
  • Hysteresis 0.001
  • Input Resistance 350 ± 10 Ω
  • Interchangeability 0.0025
  • Linearity ± 0.1%
  • Load Cell Capacity 7500 kgf
  • Load Cell Type Pancake
  • Materials Stainless Steel
  • Non-Linearity 0.001
  • Operating Temperature, Max 75 °C
  • Operating Temperature, Min -40 °C
  • Diamètre extérieur 102 mm
  • Surcharge, max 300% FS
  • Température maximale du processus 71 °C
  • Température minimale du processus 16 °C
  • Répétabilité 0.0005
  • Surcharge sécurisée 150% FS
  • ID de série LCM412-IS
  • Tension d'alimentation 10 to 28 Vdc
  • Effet de la plage thermique ± 0.009% rdg/°C
  • Effet thermique zéro ± 0.009% FSO/°C
  • Filetage du trou traversant M24 x 2.0
  • Tableau de câblage/connecteurs Pin 1: (+) Input; Pin 2: (-) Input; Pin 4: Case
  • Erreur de zéro/équilibre 4 mA +10%, -2% adjustable

Supported Applications

The Omega LCM412-IS series comprises intrinsically safe, low-profile load cells designed for tension or compression applications in hazardous locations. These units are intended for use exclusively in the USA and Canada where FM Intrinsically Safe ratings apply to Class I, II, III environments.

Operating Conditions & Performance

The series operates within an ambient temperature range of -40 to 75°C (-40 to 167°F) with a compensated temperature span of 16 to 71°C (60 to 160°F). Measurement capabilities cover capacities from 50 to 750,000 lb and 25 to 10,000 kgf. Performance specifications include nonlinearity and hysteresis at 0.10 %F.S.O., repeatability of 0.05 %F.S.O., and a zero balance adjustable by ±10% with -2%. The units support an excitation voltage of 10-28 Vdc.

Overload Ratings

  • Safe Overload: 150% of Capacity
  • Ultimate Overload: 300% of Capacity

Hazardous Location Approvals

The series holds FM Intrinsically Safe ratings for Class I, II, III, Division 1 Groups A, B, C, D, E, F, G. It is also rated for Class I, Zone 0 (AEx ia IIC in the US; Ex ia IIC in Canada) with a temperature code of T4.

Configuration Options

The LCM412-IS series offers configurable electrical terminations and output options to suit specific installation requirements. The housing is constructed from stainless steel, providing durability for harsh industrial environments.

Electrical Terminations (Suffix Options)

  • Suffix 0: 2 m (6.6') PVC cable with ½ NPT conduit
  • Suffix GW: 3 m (10') submersible cable with ½ NPT conduit
  • Suffix 1: PTIH-10-6P twist-lock mating connector (mating connector sold separately)
  • Suffix 5: M12 4-pin
  • Suffix 6: mini-DIN (mating DIN connector not included)

Output Signals

  • C2IS Suffix: FM Intrinsically Safe 4 to 20 mA output, calibrated 0 to full scale in compression.
  • BC2IS Suffix: FM Intrinsically Safe 4-12-20 mA output, calibrated from (-)full scale to (+)full scale for bidirectional measurement.

Mechanical Accessories

The series supports various mounting accessories including standard and metric load buttons (LBC/MLBC), male rod ends (REC/MREC), and tension base plates compatible with specific capacity ranges. Thread sizes vary by capacity, ranging from ⅜-24UNF-2B to 4-8UN-2B for imperial models and M10 x 1.5-6G to M24 x 2.0-6G for metric models.

Calibration Notes

Ranges over 300,000 lb are calibrated at 300,000 lb by default; full calibration is available upon request with the 'ZXX' suffix added to the part number. The series features a zero and span adjustment capability, though specific models may be configured without potentiometers (NP suffix).

Key Product Differences

The primary distinction within this family lies between standard imperial units (LC412-IS) and metric units (LCM412-IS), which differ in capacity increments and thread specifications. The series also differentiates based on output directionality: the C2IS option provides unidirectional compression measurement, while the BC2IS option enables bidirectional tension and compression monitoring via a 4-12-20 mA signal.