OM-CP-HITEMP140X2-TD-Series
High Temperature Dual Channel Data Loggers
- OM-CP-HITEMP140X2-TD-FP-72 Has One Rigid Ambient Probe and One Flexible Probe
- OM-CP-HITEMP140X2-TD-PT-1 and OM-CP-HITEMP140X2-TD-PT-5 Have One Rigid Ambient Probe and One Stainless Steel Bendable Probe
- Rigid Ambient Probe Measures from -200 to 260°C (-328 to 500°F)
- Flexible Probe Measures from -60 to 260°C (-76 to 500°F)
OM-CP-HITEMP140X2-TD-Series
From
£
1,086.47
Product Overview
- Battery life up to 1 yr
- Battery Size and Type 3.6V Li-ion
- Calibration Digital calibration through software
- Data Interface USB
- Data Interface Note OM-CP-IFC400 USB docking station or OM-CP-IFC406 multiplexer interface required; 125,000 baud
- Diameter 24.6 mm
- Enclosure Ratings IP68
- Form factor Handheld
- Height 48 mm
- Materials, Wetted 316 Stainless Steel, PEEK, Polyurethane
- Measurement Type Temperature
- Memory 32767
- Memory Note 32,767 readings
- Number of Measurements 2
- Operating Temperature, Max 140 °C
- Operating Temperature, Min -40 °C
- Probe Diameter 2 in
- Probe Length 0.125 in
- Readings in Trigger Settings Mode 16,383 readings
- Real Time Recording May be used with PC to monitor and record data in real time
- Relative Humidity Accuracy ± 3% RH
- Relative Humidity, Max 1
- Relative Humidity, Min 0%
- Samples,Max 33000
- Sampling Rate 1 Hz (1 update/second)
- Sampling Rate Note 1 reading every second to 1 every 24 hours.
- Series ID OM-CP-HITEMP140X2-TD-Series
- Software Compatibility Windows XP SP3/Vista/7 and 8 (32- and 64-bit)
- Start Modes Adjustable Delay Start, Immediate Start
- Stop Modes Adjustable Delay Stop, Manual Through Software
- Supply Power Type Battery
- Temperature Measurement, Max 260 °C
- Temperature Measurement, Min -60 °C
- Temperature Resolution 0.01 °C
- Temperature Sensor Type RTD
- Time Accuracy 1 minute/month @ 25°C (77°F)
- Weight 100 g
Supported Applications
The OM-CP-HITEMP140X2-TD Series are High Temperature Dual Channel Data Loggers that combine a rigid ambient temperature probe with a second remote probe. This pairing offers extreme flexibility for high temperature monitoring applications, letting a single logger capture ambient conditions and a targeted remote point simultaneously.
Each model uses a 5.1 cm (2") rigid transitional-diameter probe to measure ambient temperature, combined with a bendable or flexible second probe. The stainless steel body and remote sensing make the series suitable for oven and process mapping where both surrounding air and a specific product or fixture temperature must be logged together.
Operating Conditions & Performance
Both channels provide a resolution of 0.01°C (0.02°F) and a calibrated accuracy of ±0.1°C (±0.18°F). Measurement range depends on the probe: the rigid ambient probe covers -200 to 260°C (-328 to 500°F), the flexible probe covers -60 to 260°C (-76 to 500°F), and the stainless steel bendable probe covers -200 to 350°C (-328 to 662°F).
- Reading rate: 1 reading every second up to 1 reading every 24 hours.
- Memory: 32,767 readings, or 16,383 readings in trigger settings mode.
- Operating temperature: -40 to 140°C (-40 to 284°F).
- Enclosure rating: IP68.
- Humidity: 0 to 100% RH.
- Power: 3.6V high-temperature lithium battery included; user replaceable.
The logger body measures 48 H x 24.6 mm dia (1.89 x 0.97"). The rigid ambient probe is 51 L x 3.2 mm dia (4.8 mm transitional dia), and the flexible probe is 2.5 mm dia on a 183 cm (72") length. Wetted materials are 316 stainless steel, PEEK, and PFA insulated cable. The series carries CE and RoHS, with optional NIST calibration and optional 5 YEAR WARRANTY, and requires the OM-CP-IFC400 USB docking station or OM-CP-IFC406 multiplexer interface for operation.
Configuration Options
Every model provides the same dual-channel logger body and the same 5.1 cm (2") rigid ambient probe on channel one; the models differ in the second probe fitted on channel two.
Rigid ambient plus flexible probe
The OM-CP-HITEMP140X2-TD-FP-72 pairs the rigid ambient probe with a 183 cm (72") flexible probe, giving a long, highly routable remote sensor. This configuration weighs 100 g (3.5 oz).
Rigid ambient plus bendable probe
The OM-CP-HITEMP140X2-TD-PT-1 and OM-CP-HITEMP140X2-TD-PT-5 pair the rigid ambient probe with a 61 cm (24") stainless steel bendable probe, differing in the bendable probe tip: the PT-1 uses a 2.5 cm (1") tip and the PT-5 uses a 12.7 cm (5") tip. These configurations weigh 85 g (3.0 oz) and add the bendable probe's wider -200 to 350°C (-328 to 662°F) range.
Key Product Differences
The model lineup consists of the following dual-probe configurations:
- OM-CP-HITEMP140X2-TD-FP-72 — high temperature data logger with one 5.1 cm (2") rigid ambient probe and one 183 cm (72") flexible probe.
- OM-CP-HITEMP140X2-TD-PT-1 — high temperature data logger with one 5.1 cm (2") rigid ambient probe and one 61 cm (24") bendable stainless steel probe with 2.5 cm (1") tip.
- OM-CP-HITEMP140X2-TD-PT-5 — high temperature data logger with one 5.1 cm (2") rigid ambient probe and one 61 cm (24") bendable stainless steel probe with 12.7 cm (5") tip.
Each configuration is also available with a NIST calibration certificate (-CERT). Required interfaces are the OM-CP-IFC400 and OM-CP-IFC406, and the OM-CP-BAT110 is the replacement 3.6 V high temperature lithium battery.
Software & Drivers