Skip to search Skip to main content Skip to navigation

United Kingdom 0800 488 488 | Intl +44 (0) 161 777 6611 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.
Back To Top

DIN Rail Signal Conditioners

30 Products
DIN Rail Signal Conditioner Series with Model Specific Input Type

CCT DIN rail conditioners that accept various input signals, such as voltage and current, frequency, temperature (TC and RTD), and provide 0/4 to 20 mA, or 0 to 10 Vdc.

DIN Rail Temperature Loop Powered Signal Conditioner

The DRSL-TEMP is an output loop powered temperature signal conditioner. Accepts Type J, Type K, or 2, 3 or 4 wire Pt100 RTD input. Slim housing, high accuracy.

DIN Rail Frequency Input Signal Conditioner | Configurable

The DRST-FR converts frequency/pulse inputs to a 4-20mA or 0-10V DC output. PNP/NPN output, relay output. Universal power supply. Configurable with TXUN-KIT device.

DIN Rail Output Loop Powered Isolators w/ 1 or 2 Channel Models

The DRSL-LPO Series Conditioners are 1 or 2 channel output loop powered 2 wire isolators. 1:1 signal ratio, low voltage drop, slim housing. 0.05% accuracy.

DIN Rail Transmitter with RFID Communications

TXDIN400 series transmitters accept thermocouple or RTD input (TX401) or process voltage, current, or resistance (TX402). Configurable via RFID with TX400-RFID accessory.

DIN Rail AC Current and Voltage Transmitter

The DRST-AC measures AC current or voltage signals and outputs passive or active current signals. UL and c-UL approved. Universal power. Programmer required.

DIN Rail Signal Conditioner for AC LVDT Transducers

The LDX-D is a DIN rail mount AC LVDT transducer that operates on 10-30Vdc power with selectable process outputs. Adjustable signal polarity, span, and offset.

Non Isolated Loop Powered DIN Rail RTD Input Conditioner

The DRSL-RTD-LP is a 2, 3, or 4-wire PT100 RTD input conditioner. Output loop powered with high accuracy and slim housing. Pre-calibrated temp range DIP switch selected.

DIN Rail Field Configurable Alarm Limit Modules

The DRG-AR Series Conditioners are TC, RTC, DC or AC voltage and current input with 2 SPDT Relay Outputs. Field configurable ranges with adjustable setpoints.

DIN Rail Isolated Repeater/Splitter for Bipolar Process Signals

The DRSL-SP3 is a repeater/splitter that isolates and converts 1 bipolar process input to 2 process outputs. DIP switch selectable ranges, slim housing, high accuracy.

DIN Rail Signal Conditioners

DIN Rail Signal Conditioners support data acquisition workflows by helping users measure, condition, record, transmit, or review field information. Products in this category span DIN rail signal conditioners for temperature, voltage, current, frequency, process transducer, bridge, strain gage, load cell, mA, voltage, and RS-485 applications.

Applications include control panel signal conversion, sensor-to-PC acquisition, PLC inputs, bridge and load-cell signal transmission, process monitoring, and retrofit work where DIN rail mounting is preferred. Products represented in the source data include Omega Engineering.

Applications include:

  • Convert raw sensor or process inputs
  • Provide mA, voltage, or RS-485 outputs
  • Mount devices in DIN rail control panels
  • Condition bridge, strain gage, and load-cell signals
  • Interface field sensors with controllers or acquisition systems
Searching for your items
en-GB
en_UK
Save Configuration