United Kingdom 0800 488 488 | Intl +44 (0) 161 777 6611 | Welcome to our new website, found an issue or bug? Please report it here
CT5100-Series
1 or 2 Channel Programmable Process Input Circular Recorders
- 254 mm (10') Chart
- 1- or 2-Pen Versions,
- Thermocouple, RTD, dc Current, or Voltage Input
- Programmable Inputs
CT5100-Series
From
£
1,957.33
Product Overview
- Accuracy ± 0.5 %
- Accuracy Detail Chart Recording: 0.5% of chart span reference accuracy, Chart Rotation: ±0.5% of rotation time, assuming all backlash removed, Chart Rotation: ±0.5%, Chart Speed: ±1%
- Approvals Note Safety: UL Approved for USA:UL 1092, UL 916 and QUXY, pending UL Certified for Canada:CSA Spec 142, pending Limit/Device: FM, pending
- Chart Diameter 254 mm
- Chart Note Chart Span: Bottom and top of span, -9999 to 9999 units; Chart Drive: DC Stepper Motor; Chart Drive: Stepper Motor
- CMRR >120 dB @ 50/60 Hz, 260 Vac max
- Cold Junction Compensation 0.04°/°C deviation from 25°C
- Conduit Entrance 3 Openings on the Right Side
- Current Measurement Range 0 to 20 mA
- Cutout Dimensions 322.58 x 322.58 mm
- Data protection EEPROM Storage
- Display Note 4-digit, 14 mm H (0.56"), red, 7-segment, LED display, Display Modes: Normal: process value(s) or blank Keypad: 3 keys for programming and unit operation
- Display Type LED
- Enclosure Ratings IP54, NEMA Type 3
- Height 355.6 mm
- Impedance Input >100 MΩ for T/C and mV inputs, 100 kΩ for 5 V inputs, 4.7 Ω for µA inputs
- Input Note Input Correction: Offset adjustment: 999 to 999 units;Input Isolation: 350 Vac, 500 Vdc
- LED Indicators 5 Red LED Alarm Status Indicators, 1 green LED pen 2 indicator
- Length 96.5 mm
- Materials Noryl, Acrylic
- Measurement Range Note Thermocouple: J: 0 to 760°C, K: 0 to 1360°C, T: -200 to 400°C, R: 200 to 1650°C, S: 200 to 1650°C RTD: -140 to 400°C Current: 0 to 20 mA, 4 to 20 mA Voltage: 0 to 25 mV, 0 to 50 mV, 10 to 50 mV, 0 to 5 V, 1 to 5 V
- Measurement Type Thermocouple, RTD, Current, Voltage
- Mounting Panel Mount or Wall Mounting
- NMRR 85 db @ 60 Hz or greater
- Operating Environment Reference Operating Condition: 25 °C
- Operating Temperature, Max 50 °C
- Operating Temperature, Min 0 °C
- Panel Depth 64 mm
- Panel Protrusion 33 mm
- Pen Type Disposable Fiber tip
- Power Consumption 18 VA
- Relative Humidity 10 to 90% RH, non-condensing
- RTD Type 100 Ω Pt sensor; α= 0.00385
- Sampling Rate 1 Scan per second for Non-RTD inputs; 1 Scan per 1.2 seconds for RTD inputs
- Sensor Input Configuration 150 µA
- Series ID CT5100-Series
- Standard Limits of Error Error Limit: Cold-Junction Compensation Error: ±0.2°C @ 25°C, Linearization Error: T/Cs: ±0.25°C typical, ±0.5°C worst case , RTDs: ±0.1°C typical, ±0.3°C worst case, Ambient Temperature Error: ±0.01% of span per °C deviation from 25°C; Measurement Error: Type J, K, T, R, S and RTD: ±0.25% of span ±1 degree; mA, mV and Vdc: ±0.25% of scaled span plus 1 leastsignificant digit
- Storage Temperature, Max 65 °C
- Storage Temperature, Min -40 °C
- Supply Power Note Line Voltage: 90/264 Vac, 50/60 Hz; optional: 20 to 50 Vac, 50/60 Hz, or 22 to 65 Vdc
- Supply Power Type AC
- Supply Voltage 90 to 264 Vac
- Switch Rating 5 A @ 115 Vac
- Switch Rating Note Relays: SPDT; contacts rated 5 A resistive @ 115 Vac,2.5 A resistive @ 230 Vac, 1⁄8 hp @ 230 Vac (single phase),250 VA @ 115/230 Vac
- Switch Type SPDT NO/NC, Selectable
- Temperature Measurement Range J: 0 to 760°C, K: 0 to 1360°C, T: -200 to 400°C, R: 200 to 1650°C, S: 200 to 1650°C, RTD: -140 to 400°C
- Thermocouple Type J, K,T, R, S
- Voltage Measurement Range 0 to 25 mV, 0 to 50 mV, 10 to 50 mV, 0 to 5 V, 1 to 5 V
- Weight 8.8 kg
- Width 355.6 mm
- Wire Code Option 2- or 3- Wire
CT5100 Series Circular Chart Recorders measure and display up to two process variables. Choose from a variety of programmable inputs. All recorder and alarm functions are easily configured via front 3-key pad with self prompting displays. Total panel depth of only 2.5" is required with only a 1.3" protrusion from the front of the panel.