Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

LDI-619

LVIT Linear Position Sensors

Models In Stock
  • Excellent stroke-to-length ratio
  • Rugged 19 mm (0.75') Diameter stainless steel housing
  • Field adjustable range scaling
  • Wide Choice of Range: 15 to 750 mm (⅝” to 30') Full Scale
LDI-619
From C$ 361.98
Models In Stock
LVIT Linear Position Sensors LDI-619 LDI-619
loading all models
Product Overview
  • Additional Features 1 Non-Contact LVIT
  • Bandwidth 300 Hz (-3 dB)
  • Cable Type Insulated
  • Enclosure Ratings IP67
  • Housing Material Stainless Steel
  • Operating Temperature, Max 85 °C
  • Operating Temperature, Min -20 °C
  • Relative Humidity 95% RH, non-condensing
  • Resolution 0.025% of FS
  • Series ID LDI-619
  • Shock 1000 g, 11 ms
  • Temperature Coefficient 0.015% of FS/°C
  • Vibration 5 to 20 Hz, 0.5" p-p; 20 to 2000 Hz, 4.2 g p-p

Supported Applications

The Omega LDI Series Linear Sensors are designed for linear position measurement. The series provides field programmability and calibration procedures suitable for displacement sensing applications requiring analog output signals.

Operating Conditions & Performance

These sensors operate on a 12-30 V DC excitation voltage, with a minimum requirement of 18 V DC when configured for the 4-20 mA current output. The series supports two primary analog output signals: 0-10 VDC and 4-20 mA. For the 4-20 mA configuration, the system utilizes a 3-wire sourcing architecture; it is specified not to connect this output to a 2-wire loop-powered system.

Field programmability allows for calibration adjustments within specific ranges: 0-20% around zero or 80-100% around full range. The default setting provides the standard analog output span without additional programming constraints at both ends of these ranges.

Electrical Specifications

  • Excitation Voltage: 12-30 V DC (min. 18 V DC for 4-20 mA current output)
  • Analog Output Options: 0-10 VDC or 4-20 mA
  • Load Resistance: 250 Ohms or 500 Ohms
  • Output Configuration Note: The 4-20 mA DC output is 3-wire sourcing; do not connect to a 2-wire loop-powered system.

Configuration Options

The LDI Series offers configurable electrical connections and calibration ranges. Sensors are available with either a 4-conductor cable or a PTO2-10 6-pin connector interface. The series supports CE certification for applicable markets.

Connection & Wiring Options

  • Cable Type: 4-conductor cable
  • Connector Option: PTO2-10 6-pin connector
  • Pin Assignments (PTO2-10):
    • Pin E: + Power Input (Red)
    • Pin D: Common Ground (Black)
    • Pin A: Analog DC Output 0-10 V or 4-20 mA (Green)
    • Pin B: Field Programmability/Calibration (White)

Field Programming Ranges

  • Range Option: 0-20% around zero or 80-100% around full range.
  • Default Setting: Standard output span (0-10 VDC / 4-20 mA) without restricted end-range programming.

Key Product Differences

The LDI Series is distinguished by its dual-output capability and field-programmable calibration ranges. The series provides a choice between voltage (0-10 VDC) and current (4-20 mA) outputs, with the latter requiring specific power supply conditions (minimum 18 V DC). Variants differ primarily in their physical stroke lengths as indicated by model codes ranging from short strokes to extended travel distances.

Wiring configurations vary between a standard 4-conductor cable and an optional PTO2-10 6-pin connector, with specific color-coding or pin assignments defining power, ground, signal output, and calibration inputs. The series does not support 2-wire loop-powered systems for the current output variant.

Rated 5 out of 5 by from LVDT (0-50 mm) I received the product on time and it works perfectly fine. I have ordered three of these till now and never had issues.
Date published: 2022-10-26
  • y_2026, m_8, d_8, h_9
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_CA, sid_LDI-619-015-A010S, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT

Hi. Do you have a recommended power supply for this item?

Asked by: rdoc
rdoc, Please see PSR-24L https://www.omega.com/en-us/sensors-and-sensing-equipment/sensing-accessories/power-supplies/psr-24s-series/p/PSR-24L Thank you
Answered by: SAE ENGINEER GUY
Date published: 2020-04-22

Hi, could you please tell me how long the threaded end (M5x0.8) for installation is? Unfortunately there is nothing mentioned about this length in the spec sheet or manual. Please advise. Thanks, Manuela

Asked by: Manuela
Length of the M5x0.8 threaded area at end of the shaft is 9.7mm (0.38"0
Answered by: JKengineer
Date published: 2020-02-13

Hi are you able to apply pressure to retract this product to zero position? (spring load, compressed air, etc) I only see one photo so I don't know if this possible.Thank you

Asked by: splhs
Thank you for your inquiry, this unit isn’t spring loaded or pneumatic. Please see our model GP911-1-P
Answered by: rkent
Date published: 2023-01-17

Do these sensors come with signal conditioners? If not, which signal conditioners do you offer are most compatible with these sensors?

Asked by: AJKJD
No signal conditioning is required with these sensor. The output is already conditioned to either a 4 to 20 mADC or 0 to 10VDC signal
Answered by: Applicatrions Engineer JK
Date published: 2021-02-09

The "stud" came with insulation over the majority of its length. Is that to be left on or removed?

Asked by: DanP
Thank you for your inquiry, yes, the insulation can be removed
Answered by: rkent
Date published: 2022-07-14
  • y_2026, m_8, d_8, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_5
  • loc_en_CA, sid_LDI-619-015-A010S, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 10ms
  • QUESTIONS, PRODUCT