Isolated Strain Amplifier/Conditioner for Bridge-type Inputs

  • 700 V I/O Isolation
  • 1100 V Line Isolation
  • Power for Four 350 Ohm Load Cells, Fixed 10 V or Variable 5 to 10 Vdc
  • Adjustable Gain and Offset
DMD-475-Series-Sig-Cond
From C$ 1 258.41
Isolated Strain Amplifier/Conditioner for Bridge-type Inputs DMD-475-Series-Sig-Cond DMD-475-Series-Sig-Cond
loading all models
Product Overview
  • Accuracy ± 0.15 %
  • Capacitance 60 pF
  • Compliance Voltage 20 Vdc
  • Current Output 5 mA
  • Excitation Voltage Note Voltage Range: 5 to 10 Vdc Current Output: 120 mA max Line and Load Regulation: 0.02% max Output Noise: 1 mVrms max (120 Hz) Temp Coefficient: 60 ppm @ 10V, 100 ppm max
  • Gain Range 200 to 2000
  • Height 73 mm
  • Input Range 5 to 50 mV
  • Input Resistance 1000 MΩ
  • Input Type Voltage
  • Isolation AC Line: 1100 Vrms, 60 pF, Input to Output: 700 Vdc and 60 pF
  • Length 96 mm
  • Linearity ± 0.005%
  • Long Term Stability Temperature: 0.005%/°C
  • Operating Temperature, Max 55 °C
  • Operating Temperature, Min -25 °C
  • Response Time 35 ms
  • Response Time Note 10 to 90% = 35 ms
  • Series ID DMD-475-Series-Sig-Cond
  • Storage Temperature, Max 85 °C
  • Storage Temperature, Min -25 °C
  • Supply Power 120 Vac
  • Supply Power Note 115 Vac ± 10 Vac standard or 220 Vac ± 10% 50/60 Hz optional
  • Supply Power Type AC
  • Tare Adjustment -3 to 25 mV
  • Weight 510 g
  • Width 51 mm
  • Zero Setting Adjustable Range 0 to 2 V

Supported Applications

The Omega DMD-470 Series consists of AC-powered signal conditioning modules designed for bridge-type sensors, strain gages, and load cells. These isolated amplifiers provide triple-isolated voltage or current outputs to interface with data acquisition systems.

Operating Conditions & Performance

The series accepts input ranges from 5 to 50 mV for a full-scale output of either 0 to 10 Vdc or 4 to 20 mA. Excitation is provided as fixed 10V or variable 5 to 10 Vdc via 6-Wire Bridge Connections. The response time (10 to 90%) is specified at 35 ms.

Operating ambient temperature ranges from -25 to 55°C (-13 to 131°F), with a storage temperature range of -25 to 85°C (-13 to 185°F). Electrical isolation ratings include 1100 Vrms (60 pF) for AC output and 700 Vdc (60 pF) from input to output.

Configuration Options

The DMD-470 Series offers configurable power supplies, output types, and accessories. Both models feature dual zero/tare functions; the tare function allows up to 68% of the input to be offset while maintaining full output span.

Power Supply Options

  • 115 Vac ±10 Vac (standard)
  • 220 Vac ±10% 50/60 Hz (optional)
  • DC powered variants available for specific models

Output Signal Types

  • DMD-475: Isolated voltage output, 0 to 10 Vdc
  • DMD-476: Isolated current outputs, including 4 to 20 mA and 0 to 20 mA

Accessories

  • POWER CORD-SE: Power cord with stripped end termination

Key Product Differences

The series distinguishes between voltage and current output models. The DMD-475 provides a 0 to 10 Vdc voltage output, while the DMD-476 is configured for isolated current outputs (4 to 20 mA or 0 to 20 mA). Model numbers indicate power supply configuration: standard units operate on 120 Vac, with suffixes such as "-220V" denoting 220 Vac operation and "-DC" indicating DC-powered versions. Physical dimensions for the enclosure are 96 L x 51 W x 73 mm H (3.75 x 2 x 2.87") with a weight of 510 g (18 oz).

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Does this allow you to either calibrate and/or shunt the gauge and can you use them in 1/4 and 1/2 bridge mode?

Asked by: Lyndsey
You can use a shunt cal resistor to calibrate this unit. It's is designed for a full bridge input. You would have to complete the bridge externally.
Answered by: Applicatrions Engineer JK
Date published: 2021-07-27
  • y_2026, m_8, d_8, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_CA, sid_DMD-475, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 9ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration