Skip to search Skip to main content Skip to navigation

Netherlands 07077 03815 | Intl +31 (0) 7077 03815 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

CL510A-Series

PT100 & PT1000 RTD Simulators with multiple or single curves

  • Source One or Multiple RTD Curves
  • High Accuracy
  • Easy-to-Read Backlight Display
  • Calibrate Directly in Temperature (°C or °F)
CL510A-Series
From C$ 1,650.79
PT100 & PT1000 RTD Simulators with multiple or single curves CL510A-Series CL510A-Series
loading all models
Product Overview
  • Accuracy ± 0.015 %
  • Accuracy Detail ± (0.015% of reading + 0.05 Ω)
  • Battery Indication A low battery indication is displayed when the battery voltage drops below the operating level
  • Battery life 50 hr
  • Display Type LCD
  • Display Type Note High contrast graphic liquid crystal display, LED backlighting for use in low lit areas
  • Height 45 mm
  • Length 126 mm
  • Operating Temperature, Max 60 °C
  • Operating Temperature, Min -25 °C
  • Over-Voltage Protection Over-voltage protection to 60 Vdc (rated for 30 sec)
  • Relative Humidity, Max 0.9
  • Relative Humidity, Min 10%
  • Relative Humidity Note Relative Humidity Range, 10% ≤RH: ≤90%: 0 to 35°C (32 to 95°F), non-condensing ≤70%: 35 to 60°C (95 to 140°F), non-condensing
  • Series ID CL510A-Series
  • Supply Voltage 6 Vdc
  • Temperature Drift ± 0.05 Ω/°C
  • Voltage Source Accuracy: From 1 to 10.2 mA External Excitation Current: ± (0.015% of rdg + 0.05 Ω) Below 1 mA of External Excitation Current: ± (0.015% of rdg + 0.01 mV/mA excitation current + 0.05 Ω) Resistance Ranges: 0.00 to 410.00, 410.1 to 4001.0 Ω Allowable Excitation Current Range, Steady or Pulsed/Intermittent: <410 Ω: 10.2 mA max 410 to 001 Ω: 1 mA max Pulsed Excitation Current Compatibility: DC to 0.01 second pulse width
  • Weight 0.24 kg
  • Weight Note 0.24 kg (8.4 oz) (including batteries)
  • Width 69 mm

Supported Applications

The Omega CL510A Series consists of portable RTD (Resistance Temperature Detector) simulators designed for checking and calibrating RTD instruments. These handheld devices are compatible with smart transmitters, PLCs, DCS systems, controllers, and multichannel recorders.

Operating Conditions & Performance

The series operates within an ambient temperature range of -25 to 60 °C (-10 to 140 °F). Relative humidity limits are defined as 10 % ≤ RH ≤ 90 % (non-condensing) for temperatures between 0 and 35 °C, and 10 % ≤ RH ≤ 70 % (non-condensing) for temperatures between 35 and 60 °C. The unit provides over-voltage protection rated to 60 V dc for up to 30 seconds.

Accuracy specifications vary by excitation current conditions:

  • General Accuracy: ±(0.015% of Setting in Ohms + 0.05 Ohms)
  • External Excitation Current (1 to 10.2 mA): ±(0.015% of Setting + 0.05 Ohms)
  • Below 1 mA External Excitation Current: ±(0.015% of Setting + 0.01 mV/mA Excitation Current + 0.05 Ohms)

The device supports resistance ranges from 0.00 to 410.00 Ω and 410.1 to 4001.0 Ω. Temperature drift is specified as ± 0.05 Ohms/°C.

Configuration Options

The CL510A Series offers configurable simulation capabilities based on the selected model variant, supporting single or multiple RTD curves with specific alpha coefficients and temperature ranges:

  • Sensor Types Supported: Pt 100 Ohm (DIN/IEC/JIS 1989, Burns, Old JIS 1981, US Lab), Pt 1000 Ohm (DIN/IEC/JIS 1989, Hy-Cal HVAC), Copper 10 and 50 Ω, Ni 120 Ohm (Pure), and Ni 110 (Bristol 7 NA).
  • Electrical Connections: Configurable for 2, 3, or 4 wires matching the sensor connections.
  • Pulsed Excitation Compatibility: Supports DC to 0.01 second pulse width.

The unit features a high-contrast graphic LCD with LED backlighting and an adjustable digital potentiometer 'DIAL' knob for precise output adjustment in °C, °F, or ohms (resolution of 0.1° or 0.01/0.1 ohm increments). It includes the ability to store up to three preset temperature values.

Power is supplied by four 'AA' Alkaline 1.5V (LR6) batteries, providing approximately 50 hours of battery life with a low-battery indication at roughly one hour remaining. An optional Ni-MH rechargeable kit (Part Number: 020-0103) is available for North America only.

Key Product Differences

The series distinguishes between two primary model configurations:

  • CL510A-1: Simulates a single RTD type (Pt100, alpha 0.00385).
  • CL510A-10: Supports up to ten different RTD types including various Platinum, Copper, and Nickel standards.

Both models include a Certificate of Calibration traceable to NIST (no points) and carry CE marking for European New Approach Directives. Optional accessories include a rubber boot (Part Number: 020-0209 or CL500A-RB), an RTD Wire Kit (Part Number: 020-0208), and a small carrying case (Part Number: SC-HH500).

Accessories

accessories

RUBBER BOOT
€ 131,08 / each
0 In Stock
8X2X3.5" SOFT CASE
/ each
0 In Stock
This item is discontinued. Please contact Technical Sales Team for assistance.
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 13ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-NL
en_CA
Save Configuration